Inspection during construction - Concrete footings & slabs
-
Add image of site
-
With reference to structural plan number
Set-out
-
Distances from easements, Sydney water assets and Local Government Infrastructure confirmed?
Excavation of Foundation Material
-
Dimensions of excavation
-
Bearing surfaces of excavation
Compaction of Fill Material (if necessary)
-
Compaction Level/Density
Cut & Fill Batters
-
Location of Cut & Fill Batter
-
Construction and location of retaining walls (all retaining walls must be detailed before construction)
-
Provision of drainage for retaining walls
-
Falls to external finished areas i.e. away from habitable slab edges
Drainage Elements
-
Incorporation of drainage elements per approved plans
- Yes
- No
- N/A
-
Provision of falls to drainage elements
- Yes
- No
- N/A
Piers through fill
-
Location of piers through compacted fill
-
Depth and bedding of piers through compacted fill to natural ground or in accordance with approved design requirements
Reinforcement of Slab and Footing System
-
Type and placement of steel reinforcing
-
Size and gauge of reinforcing steel
-
Location and dimension of laps to reinforcement steel (refer typical detail sheet)
Vapour Barrier
-
Type and location of vapour (polythene or equivalent)
-
Type and location of joint overlaps to vapour barrier
-
Treatment to penetrations through vapour barrier (taped and lapped as with overlaps)
Control Joints
-
Provision for saw cuts per approved plans
- Yes
- No
- N/A
-
Provision for doweled expansion joints per approved plans
- Yes
- No
- N/A
Other verbal advice provided to owner/contractor
-
undefined
Inspection Result
-
Result of the inspection
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory - reinspection required after rectification works carried out
- Unsatisfactory - works not complete
- Stop all works - contact councils duty planner on 9735 1222, regarding unauthorised works
-