Title Page
-
Customer's Name
-
Customer's Phone No.
-
Date & Time Attended
-
Prepared by
-
Customer's Address
GENERAL INFORMATION
-
Transmitter Type
-
Software
-
Remote Signalling Make/Type
-
Site Contact
-
Telephone No.
ROUTINE INTERM MAINTENANCE CHECKLIST (interim Inspection Visit)
-
Check with customer for any problems with system or alterations to site.
-
Visually check the installation for any signs of damage
-
Remove all Movement Detector housing covers and check/Clean
-
Check all movement detection for correct operation
-
Silicon seal top of Movement Detection to prevent water ingress
-
Check all camera for correct operation
-
Clean all camera viewing windows/Bubble (outside)
-
Check PTZ Domes for correct operation - Respond to alarm inputs
-
Test transmitting equipment to ARC. Check secondary path if applicable
-
ARC to make test Audio announcement to site
-
Check Recording Device for correct operation
-
Check all UPS for correct operation Date unit.
-
Change UPS with Service replacement if 2 years or more old
-
Check all Low Voltage Power supply for correct operation. Date unit.
-
Check all flexible connection
-
Instruct customer on walk testing system regularly
-
Check that Time and Date are correct
-
Fill System/Site Historical Record - Issue new Record if not available
-
Remove all camera housing covers and check/Clean (inside)
-
Check all connections at camera for signs of corrosion
-
Walk Test all Movement Detection. Check that range is correct.
-
Replace Batteries in all Wireless Detection Devices
-
Check correct operation of all wireless devices through to Receiver
-
Check all connections at Detection device for signs of corrosion
-
Check with ARC that all alarm devices trigger the correct camera/preset
-
Check and clean all monitors
-
Check output Voltages on low voltage power supply
-
Check all fuses for correct value
-
Check all connections at the control equipment
-
Replace Waning signs if damaged or deteriorated
-
Check setting/unsetting procedures
SIGN OFF
-
Only the part of the system worked upon has been tested
-
The system has been tested and left in good working order
-
Time of Departure
-
Travel Time
-
Engineer's Name & Signature
-
Customer's Name & Signature