Title Page

  • Conducted on

  • Prepared by

  • Level

Insitu Wall

  • Shutters cleaned, oiled and propped

  • Thickness checked

  • Penetrations and cast in’s

  • Steel reinforcing

  • Vertical bars in correct face

  • Starter bars / correct face

  • Header beam reo

  • No bars bent on site by heating

  • Laps / Steps / Corners

  • Cover

  • Bar chairs to side forms

  • Movement joints (give centres)<br>

  • Concrete strength / slump (pic of docket)

  • No water to concrete

  • Check engineers instruction

  • Curing as soon as forms removed

  • WPM to rear of retaining walls

Insitu Column

  • Dimensions

  • Shutters cleaned, oiled and proppped

  • Angle to base forms if required

  • Steel reinforcing

  • Starter bars

  • Ties - extras top and bottom

  • No bars bent on site by heating

  • Laps length

  • Cover

  • Concrete strength / slump (pic of docket)

  • No water added to concrete

  • Check engineers instructions

  • Cure as soon as shutters removed

Precast Wall and column

  • Backing rod

  • Dowel bars - check size

  • Props

  • Weld plates

  • Grouting - dowels, joins and underside of panel

  • Sealant

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.