Title Page
-
Conducted on
-
Prepared by
-
Level
Insitu Wall
-
Shutters cleaned, oiled and propped
-
Thickness checked
-
Penetrations and cast in’s
-
Steel reinforcing
-
Vertical bars in correct face
-
Starter bars / correct face
-
Header beam reo
-
No bars bent on site by heating
-
Laps / Steps / Corners
-
Cover
-
Bar chairs to side forms
-
Movement joints (give centres)<br>
-
Concrete strength / slump (pic of docket)
-
No water to concrete
-
Check engineers instruction
-
Curing as soon as forms removed
-
WPM to rear of retaining walls
Insitu Column
-
Dimensions
-
Shutters cleaned, oiled and proppped
-
Angle to base forms if required
-
Steel reinforcing
-
Starter bars
-
Ties - extras top and bottom
-
No bars bent on site by heating
-
Laps length
-
Cover
-
Concrete strength / slump (pic of docket)
-
No water added to concrete
-
Check engineers instructions
-
Cure as soon as shutters removed
Precast Wall and column
-
Backing rod
-
Dowel bars - check size
-
Props
-
Weld plates
-
Grouting - dowels, joins and underside of panel
-
Sealant