Titelseite

  • Customer Name

  • Durchgeführt am

  • Vorbereitet von

Seite ohne Titel

  • How much power is available?

  • Is the power dedicated for eMobility?

  • Dynamic Load Management for maximum use of installation

  • For DLM an Energy Meter is necessary - For more than 63A additional Current Transformers. Up to 63A the Energy Meter is able to measure the load without current transformers.

  • The eM4 has the ability to set a static load management. You just have to set the available current via our configuration app. The feature is for free

  • How many charging points do you have in mind?

  • Our groups can support up to 30 charging points with a Controller and Extenders. The Controller is the brain of the group and responsible for loadmanagement and communication to a backend.

  • Also a Multi Group with up to 100 Charging Points can be installed. These groups can have an own static limit, but also a shared one. E.g Group 1 100A, Group 2 100A, Group 3 200A but together not more than 200A.

  • We also offer Twins and Singles. Our Twin chargers offer great value in terms of installation costs and time. Also Twin Chargers are very efficient in terms of space.

  • Our groups offer great flexibility and can be installed both wired and wireless, would you have a preferenance?

  • For LAN you need a switch, basically a star connection. All cables land to the same switch. We are also suggesting a CAT6 cable or better. The chargers can connect without a router by self assigning IP addresses by themselves. A router with DHCP can alternatively used for a detailled management of the network.

  • For WiFi we are suggest using an external Router that all chargers are connected to. Alternatively the WiFi of the chargers can be used but the conditions have to be very good (distance, no obsticles etc.)

  • We would always suggest to not connect the chargers with the IT infrastructure of the project, as IT administration can get very complicated.

  • Is billing of the charging station(s) needed?

  • An OCPP backend / CSMS is needed - Do you have a backend in mind?

  • We have a compatibility list and offer pre-configured chargers

  • If you do not have good mobile coverage (LTE/4G) our chargers also support LAN and WiFi with a router.

  • In special cases like underground parking, a router can be used with a Sim Card to relocate to a better place in regards of mobile coverage

  • Do you want to use a credit card with your chargers for Payment?

  • Our Payment Terminal is the perfect solution. We have to check if our payment solution is compatible with the OCPP backend of the customer

  • We are also offering several accessories. Our poles can be an elegant solutions for many projects

  • The Pole Slim is a cost effective solution that can also have two wallboxes on each side (Twin or Single). The POLEM4 has more space for the installer and a DIN Rail + LED for better UX at night.

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.