Information
-
Document No. 974000-0055-00-126 Issue 01
-
Audit Title
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
-
Document No.
Appointment of Lamproom Personnel
Appointments
-
Appointed
Lampsman
-
Name:
-
Certificate Number:
-
Date of Appointment:
Appointment of Lampsman
-
Is he/she appointed by the manager?
-
Is he/she certificated by the department (Reg 28.46.1)?
-
Is the certificate available in the lamproom (Reg 28.46.1)?
-
Lamps person's duties and responsibilities defined in writing?
Appointment of Relief Lampsman
-
Does the lamp person have a relief?
-
Is the relief officially appointed by the manager?
-
Is the relief certificated by the department (Reg 28.46.1)?
-
Is the certificate available in the lamproom (Reg 28.46.1)?
-
Relief lamps person's duties and responsibilities defined in writing?
Appointment of Lamproom Attendants
-
Are the lamproom attendants appointed by the Lampsman?
-
Lamproom attendants duties and responsibilities defined in writing?
Training of Lamproom Personnel
Training of Lamproom Personnel
-
Is the Lamps person and Relief trained by the various OEM's?
-
Gas Detection Intrumentation
Lampsman
-
Supplier
-
Model
-
Certificate Number
-
Date of Issue
-
Expiry Date
-
Portable Lamps
Lampsman
-
Supplier
-
Model
-
Certificate Number
-
Date of Issue
-
Expiry Date
-
Self-Contained Self-Rescuers
Lampsman
-
Supplier
-
Model
-
Certificate Number
-
Date of Issue
-
Expiry Date
-
Is training done annually by the OEM's?
-
Is the Lamproom attendants trained by the various OEM's?
-
Are certificates to this effect issued and displayed?
Training of OEM and/or Accredited Person
-
Is the OEM Technician or accredited person certified to do repairs?<br><br>
-
Are certificates to this effect issued and displayed?
Lamproom Code of Practice
Lamproom Code of Practice
-
Signed copy of Lamproom Code of Practice available (Section 9(1))? Does it cover all types of equipment in use?
-
Does it comply with the guidelines issued by the Chief Inspector of Mines?
-
Is the COP displayed on a notice board for everyone to see?
-
Is everybody concerned aware of the requirements? Is the lamproom personnel informed (by the Lampsman) on the contents of COP?
-
Has provision been made for it to be reviewed?
-
Document reference number:
-
Effective Date:
-
Last Revision Date:
-
Next Revision Date:
Storage of Equipment
Storage of Equipment
-
Must include:
- Gas Detection Equipment
- Self-Contained Self-Rescuers
- Portable Lamps
- Gas Cylinders
Work environments and infrastructure: -
Are storage areas well ventilated and illuminated?
-
Are storage areas clean and free from sensor poisoning agents (e.g. Brasso, paint, any polish cleaning agents containing silicon's)?
-
Is there a separate room available for maintenance and repair?
-
Are equipment stored as per statutory requirements? Stored in accordance with OEM's recommendations?
-
The handling and storage of chemicals correctly identified, recorded and addressed?<br><br>- Acid e.g. Sulphuric compound <br>- Lead compounds <br>- Paint <br>- Silicon <br>- Cleaning agents and detergents <br>- Gasses<br>- Chlorine products <br>- OEM guidelines <br>- Material Safety Data Sheet (MSDS)<br><br>
-
Scraping procedure in relation to site specific and legal requirements? <br><br>- Environmental impacts <br>- Recycle<br>- Removals <br>- OEM Requirements
Allocation of Equipment
Allocation of Equipment
-
Allocation of equipment in compliance with SANS specifications.
Must include:
- Gas Detection Instrumentation
- Self-Contained Self-Rescuers
- Portable Lamps -
Is there a system or programme in place for monitoring equipment allocations?
-
Is there a record of users allocated?
-
Are equipment allocated on a personal basis?
-
Is there a allocation history available for each unit/user?
-
Are records kept of equipment de-allocation and re-allocation?
-
Is there a record of non-moving equipment?
Asset Clearance
Asset Clearance
-
Is there a asset/shift clearance procedure in place?
-
Are shift clearance procedures adhered to and the necessary reports submitted?
Portable Mine Lighting Equipment
Certification of Specifications Compliant
-
Portable Lamps (SANS 1438:2013)
-
Is the product approved by the Chief Inspector of Mines (DMR Approved)?
-
PN Certificate(s) for all model/type's approved?
-
Batch Test Reports Available, All serial numbers covered?
Approved Equipment Requirements
-
Portable Lamps
-
Model
-
Supplier
-
Number Available - (Total)
-
Number Available - (InUse/Allocated)
-
Number Available - (Spare)
-
Is there sufficient number of portable lamps available? Is each user issued or allocated with his/her own personal portable lamp?
-
Is there 10% spare portable lamps available?
Records of Spare Portable Lamps Issued
-
Is a "Spare Allocation List" available?
-
Does the list reflect the company number ("details") of the end user?
-
Does the und user sign for the portable lamp allocated to him for the shift, when receiving?
-
Do the end user / lamproom personnel sign/check the portable lamp back?
Portable Lamps Inspection, Maintenance and Repair
-
Are engineering drawings and specifications readily available and displayed? Poster with exploded view displayed? All model/type's covered?
-
Is an OEM maintenance and repair manual available?
-
Does the Lampsman ensure that portable lamps are checked on a daily basis to verify that equipment is in working order prior to every shift?
-
Are inspections conducted on RF devices ( where applicable)?<br>- Data Radios <br>- CWS visual and audible devices <br>- Active / Passive Tags
-
Are portable cap lamps: locked, sealed, headpiece, top cover, cable and battery not defective?
-
Are defective portable mine lighting equipment identified and repaired?<br><br>- Cap Lamps <br>- Loco-Lights
-
Are old/used scrapped batteries stored or discarded as per statutory requirements?
-
Scraping procedure in relation to site specific and legal requirements? <br><br>- Environmental impacts <br>- Recycle<br>- Removals <br>- OEM Requirements
-
Are maintenance and repair records kept?
-
Is there a service history available?
-
Do records reveal re-test and/or re-burn down after repairs were conducted?
-
Are testing and repairs of portable mine lighting equipment conducted?
Must include:
- Cap Lamps
- Loco-Lights -
Is a monthly check done on the illumination level and focus of each portable lamp?
-
Are battery burn downs conducted on portable mine lighting equipment in relation to site specific and OEM requirements?
Must include:
- Cap Lamps
- Loco-Lights -
Are all portable lamps checked and discharged accordance with the OEM's recommendations?
-
Units not inspected removed from service?
-
Do repair and maintenance records correlate?
-
Are re-test and re-burn downs conducted?
-
Hospitalization process?
Battery Charging Equipment
-
Are battery charging racks securely installed?
-
Are batteries charged as per OEM specification? (Voltage and ampere testing)?
-
Are battery charging equipment checked in accordance with site specific and OEM requirements?
Gas Detection Instrumentation
Certification of Specifications Compliant
-
Gas Detection Instrumentation
-
SANS 101515 Batch Test Reports Available, All serial numbers covered?
-
SANS 6079-0&11 Compliance, Intrinsically Safe Apparatus Report Available?
Approved Equipment Requirements
-
Gas Detection Instrument
-
Model
-
Supplier
-
Number Available - (Total)
-
Number Available - (InUse/Allocated)
-
Number Available - (Spare)
-
Is there sufficient number of instruments for each user per section/shift?
-
Is there 10% spare instruments available?
Gas Detection Instruments Pouches
-
Do all GDI pouches have an attachment / means which entitles the user to elevate the instrument?
-
How are pouches maintained? - On users onus
-
Is there a sufficient number of spare pouches available?
Issuing and Controlling Gas Detection Instruments
-
Equipment tested / checked as per OEM recommendation and site specific requirements?
-
Are pre-shift visual inspections conducted?
-
Are pre-shift functional tests and checks conducted?
-
Proof that the user has tested/checked the instrument? (Exception Report)
-
Does the end user sign for the instrument allocated to him for the shift, when receiving it? (Issue/self-help)
-
Are post-shift inspections or tests conducted?
-
Do the end user / lamproom personnel sign/check the instrument back?
Records of Spare Gas Detection Instruments Issued
-
Is a "Spare Allocation List" available?
-
Does the list reflect the company number ("details") of the end user?
-
Does the und user sign for the instruments allocated to him for the shift, when receiving?
-
Do the end user / lamproom personnel sign/check the instrument back?
Checking and Testing Gas Detection Instruments
-
Does the lamproom personnel conduct visual inspections / checks on the gas detection instruments prior to each shift?
-
Routine inspections and tests?
-
- Functional check
-
undefined
-
- Battery Condition
-
undefined
-
- Display
-
undefined
-
- Visual Indication (Alarm visible)
-
undefined
-
- Audible check (Alarm audible)
-
undefined
-
- Casing Condition
-
undefined
-
- Cleaning
-
undefined
-
Are defective ("faulty") instruments identified, removed from service and repaired?
General Maintenance of Gas Detection Instruments
-
Are engineering drawings and specifications readily available and displayed? Poster with exploded view displayed? All model/type's covered?
-
Is an OEM maintenance/repair manual available?
-
Are testing and repairs of gas detection instrumentation conducted?
-
Are maintenance and repair records kept?
-
Is there a service history available?
-
Do records reveal re-test and re-calibration in the event of repairs conducted?
-
Do records reveal re-burn down in the event of a battery replaced?
-
Are battery burn downs conducted on gas detection instrumentation in relation to site specific and legal requirements?
-
Are all gas detection instruments checked and discharged in accordance with the OEM's recommendations?
-
Units not inspected removed from service?
-
Repair and maintenance records?
-
Re-test and Re-burn down?
-
Hospitalized process?
Gas Test Points (GTP) and Flow Meters
-
Are enough test points available?
-
Is the GTP indelibly marked with the OEM's contact details?
-
Does each point have a flow meter?
-
Is the flow rate set and marked as per OEM recommendation?
-
Is the gas concentration displayed at the GTP's?
-
Methane
-
Carbon Monoxide
-
Oxygen
-
Nitrogen
-
Notice displaying type and % or ppm of gas at testing points, and duration of test? (alarm level, response time)
-
Are records kept of maintenance and inspections conducted on GTP?
-
Does the OEM or accredited person do repairs?
-
Is an OEM accreditation certificate available?
Calibration of Gas Detection Instruments
-
Are gas detection instruments calibrated in accordance with site specific and OEM requirements?
-
Are calibration masks available for all models, OEM designed / identified and correctly used?
-
Is the flow rate set to the OEM recommendation?
-
Are calibration done according to a written procedure?
-
Are calibration records available?
-
Are all gas detection instruments calibrated and recorded on file, including units not in service and/or use?
-
Do calibration records reveal the following information:
-
GDI (Product Information)
-
undefined
-
Visual inspection
-
undefined
-
Calibration reference gas
-
undefined
-
Calibration results
-
undefined
-
Checking and Testing (T80)
-
undefined
-
Reference to repair and maintenance records
-
undefined
-
Re-test and Re-calibration
-
undefined
-
Are the GDI real time clock set to correct time and date during calibration?
GDI Management System
-
Is the GDI Data Acquisition Unit Operational?
-
Can calibration reports be printed?
-
Can exception reports be printed?
-
Is an GDI allocation list available and updated?
-
Are records kept that users are trained to use GDI's?
Self-Contained Self-Rescuers
Certification of Specifications Compliant
-
Self-Contained Self-Rescuers (SANS 101737)
-
Batch Testing Reports Available, All serial numbers covered?
Approved Equipment Requirements
-
Self-Contained Self-Rescuers
-
Model
-
Supplier
-
Number Available - (Total)
-
Number Available - (InUse/Allocated)
-
Number Available - (Spare)
Records of Spare Self-Contained Self-Rescuers Issued
-
Is a "Spare Allocation List" available?
-
Does the list reflect the company number ("details") of the end user?
-
Does the und user sign for the SCSR allocated to him for the shift, when receiving?
-
Do the end user / lamproom personnel sign/check the SCSR back?
Checking of Self-Contained Self-Rescuers
-
Is an OEM maintenance/user manual available?
-
Are visual inspections conducted on SCSR's in accordance with the OEM's recommendation and site specific requirements?
- Are all units subjected to a daily / weekly visual check? -
Moisture indicator
-
undefined
-
Dents
-
undefined
-
Cracks
-
undefined
-
Misuse and Abuse
-
undefined
-
Seals
-
undefined
-
Cleanining
-
undefined
-
General Condition
-
undefined
-
Is any unit (which has failed routine inspection / activated / vandalized / damaged) immediately withdrawn from service, sealed in an impervious bag and stored separately from other equipment?
Condition Monitoring Service
-
Are leak/pressure tests on SCSR's conducted as per site specific requirements?
-
Reporting of suspect / defective units (Incident reports)?
-
Defective units removed from service?
-
Units not inspected removed from service?
-
Quarantined procedure (handling and storage of defective units)?
Repair and Refurbishment
-
Replacement of primary seals?
-
Replacement of defective / damaged units?
-
Are unserviceable units returned to the OEM if "No", how are they disposed of (Must be disposed of by OEM, or accredited waste disposal concern, e.g. WASTECH)
-
Procedure in relation to discontinued equipment as pet site specific and legal requirements:
-
Expired / Withdrawal
-
Removal and disposal
-
Replacement to re-stock
Functional Performance Testing (CSIR)
-
Is a functional performance testing programme by an approved testing authority in place?
-
Proof of submission?
-
Waybills?
-
Sample size - Must not be less than than 1% of SCSR at the mine
-
Is a copy of the annual functional performance assessment report available, including test certificates (All samples covered)
-
Updated on history records?
-
Replacement units to re-stock?
Records
-
Is an SCSR record available?
-
Do records reveal the following information on all units?
-
- Make of the unit (manufacturer and model)
-
- Manufacturer's serial number
-
- Mine reference number (if different from manufacturers number)
-
- Date of manufacture
-
- Date of first issue
-
- Date of purchase
-
- Allocation history
-
- Service history
-
Are records kept of the following?
-
- Information relevant to routine service agreement checks?
-
- Lost or destroyed units
-
- Upgraded or refurbished units
-
- SCSR's issued on random basis
-
- Component breakdown
-
Are records kept in terms of regulation 16.4.(2) covering the preceding 24 months?
End User Training
-
Is an training program in place?
-
Is training posters displayed?
-
Is the lampsman trained and certified by the SCSR OEM as a accredited authority to train visitors in the use of SCSR's?
-
Are visitors who require a SCSR trained in the use of a SCSR?
-
Is a record kept of visitors who have been trained?
Reporting
Reporting
-
Are statutory requirements regarding the reporting of faulty / damage / abused / missing equipment and replacement thereof applied?
-
Are statutory requirements regarding equipment not tested for functionality applied?
-
Are statutory requirements regarding reporting of equipment not taken or returned applied?
-
Are statutory requirements regarding exposure limits (PK), (STEL) and (TWA) adhered to and the necessary reports submitted? <br><br>- exception report and graph<br>- statements <br>- investigation and close out
-
Are statutory requirements regarding the issue and control of padlocks/keys applied?
-
Does the lampsman (monthly) report, in writing, to the manager on all matters pertaining to the control and condition of equipment?
-
Purchasing and receiving of new equipment
-
undefined
-
Component breakdowns
-
undefined
-
Repair and refurbishment
-
undefined
-
Calibration and Measurements
-
undefined
-
Damaged or beyond economical to repair
-
undefined
-
Lost or stolen
-
undefined
-
Equipment send off-site for repairs (RTF)
-
undefined
-
Allocation and de-allocation of equipment
-
undefined
-
Equipment movement
-
undefined
Audits
-
Are audits planned and conducted as per legal and site specific requirements?
Complaint Register
-
Is an compliant register available in the Lamproom?
-
Date of last complaint
-
Actions taken?
-
Complaint(s) resolved?
-
Is there any reoccurrences within the last month?
-
Was there any follow-up or feedback after the complaint was resolved?
Records
-
Are records kept for a period of twelve (12) months? Are records easily identified, retrievable and traceable?
Lamproom Management System
Lamproom Management System (LMS)
-
Does the lamproom personnel know how to do the following on the LMS?
-
Add new employee
-
Modify employee details
-
De-allocate equipment
-
Show employee instrument information
-
View/print GDI daily exception report
-
View/print GDI daily exception graphs
-
View/print daily GDI user report
-
View/print successful calibration report
-
View/print allocation register