Title Page
-
Environmental Area - Scrubbers towers
-
Conducted on
-
Prepared by
-
Location
Equipment/PLC/Panel/Alarms/ORP/pH/Conductivity probes
-
Instructions:
-------------------------------------
1. Rate each item as "Compliant", "Non- Compliant", "N/A".
2. Add photos and notes by clicking on the paperclip icon.
3. To add a Corrective Measure click on the paperclip icon then "Add Action", provide a description, assign to a member, set priority and due date.
4. Complete audit by providing digital signature.
5. Share your report by exporting as PDF, Word, Excel or Web Link.
PLC (Programmable logical Controller)
-
Is the screen showing all the instruments in the plant correctly?
-
Is the touchscreen working normally?
Equipment inside (pipes, leaks, valves)
-
Is the main pump of recirculation working?
-
Have you checked why?
-
Is the backup pump of recirculation working?
-
Have you check why?
-
Did you check the alarm lights on the panel are still working well?
-
Were the valves still open/closed as necessary?
-
Are there equipment without labels or number?
-
Scrubbers, pumps, panel, emergency/alarms lights are in good conditions?
Equipment outside
-
Are the fans working?
-
Is the area of the fan clean and safety?
-
Are they with the continuous flow even in weekend mode?
-
Anything equipment or piece of it need to be repaired from the maintenance?
-
Is there any different noisy comes from the pumps or other equipment that might be in failing mode or strange sound?
Operation
-
Are there products manufacturing by the production dept which they need the scrubbers on running?
-
Did you switched on the specific scrubber to attend that product is manufacturing?
-
Which mode is selected?
-
Why is in the weekend operation?
- There is no products in manufacture which need the scrubber on running.
- There is no solvents
- There is no production
-
Is the ORP probe sending signal for PLC? Please register the value is reading in the inspection moment.
-
Is the Conductivity probe sending signal for PLC? Please register the value is reading in the inspection moment
-
Is the pH probe sending signal for PLC? Please register the value is reading in the inspection moment
-
Is there the solvent or solution that scrubber needs to abatement or absorption? (H2SO4, H2O2, NaOH etc.)
-
Please proceed to the next section.
Air emissions/Compliance/Housekeeping
Air from the stack
-
The air emission is showing any visual non-conformence?<br>
-
Is the flowmeter working?
Compliance
-
Are the emissions within the ranges established from the IPC license?
-
Had you checked the emissions from the previous day?
Housekeeping
-
How are the labels in the equipment?
-
Flooring in good housekeeping?
-
Is the area clean?
-
Is the area tidy?
-
The 5S is implemented?
-
Completed by:
-
Supervisor: