Sea Maui Aux Sailing vessel standing and running rigging Information and index.

TYPE: Catamaran
OFFICIAL # REGISTRATION: 976286
LOA: 51' BEAM: 28' DEPTH: 8'
TONNAGE NET/GROSS: 22/24-simplified
SAIL AREA: Main Jib
RIG TYPE: Fractional
MAST TYPE: ALUMINUM BUILDER:
SECTION / SEAMS / TAPER: No seams No taper ????' x ????’ Mast ?????'
STEP/PARTNERS: Deck Step
AGE: 1991
LAST MAST STEP INSPECTION: Sept 2016

BOOM TYPE: ALUMINUM BUILDER:??????? GOOSENECK: 1 Aluminum
AGE: ??????
OUTHAUL/S: ???????
SPREADERS TYPE: Swept
ROOTS/BRACKETS: Brackets
SPREADER TIPS: Continuous, Double Diamond Terminates @ mast.

Is this the vessel being inspected

STANDING RIGGING

FORESTAY
WIRE TYPE/ DIAMETER: 1x19 1/2"
TERMINALS ALOFT/ TERMINALS ALOW: Swedge eye aloft Swedge stud alow
CLEVIS PIN:Aloft 7/8’ X 2 & 7/8 X 3 Alow 7/8 x 2.5 Age: 2017
LENGTH: 49"2'

UPPER CAP SHROUD PORT
WIRE TYPE/ DIAMETER: 1x19 1/2
TERMINALS ALOFT/ TERMINALS ALOW: Swedge eye aloft Swedge stud alow
CLEVIS PIN: 7/8’X 2' & 7/8 x 3' Age: 2017
LENGTH: 48"7'

UPPER CAP SHROUD STARBOARD
WIRE TYPE/ DIAMETER: 1x19 1/2
TERMINALS ALOFT/ TERMINALS ALOW: Swedge eye aloft Swedge stud alow
CLEVIS PIN: 7/8 X 2' & 7/8 x 3 Age: 2017
LENGHT:48"7'

UPPER DIAMOND PORT
WIRE TYPE/ DIAMETER: 1/19 x 8mm
TERMINALS ALOFT/ TERMINALS ALOW: Swedge eye aloft Swedge stud alow
CLEVIS PIN: 1/2' X 1 1/2' Age: 2017
LENGTH: 12"3'

UPPER DIAMOND STARBOARD
WIRE TYPE/ DIAMETER:1/19 8mm
TERMINALS ALOFT/ TERMINALS ALOW: Swedge eye aloft Swedge stud alow
CLEVIS PIN: 1/2' X 1 1/2' Age: 2017
LENGTH: 12"3'

LOWER DIAMOND PORT
WIRE TYPE/ DIAMETER: 1/19 x 8mm
TERMINALS ALOFT/ TERMINALS ALOW: Swedge eye aloft Swedge stud alow
CLEVIS PIN: 1/2' X 1 1/2' Age: 2017
LENGTH: 12"3'

LOWER DIAMOND STARBOARD
WIRE TYPE/ DIAMETER:1/19 8mm
TERMINALS ALOFT/ TERMINALS ALOW: Swedge eye aloft Swedge stud alow
CLEVIS PIN: 1/2' X 1 1/2' Age: 2017
LENGTH: 12"3'

JUMPER
WIRE TYPE/ DIAMETER: 1/19 8mm
TERMINALS ALOFT/ TERMINALS ALOW: Swedge J Hook Aloft Swedge stud below
CLEVIS PIN: 1/2' X 1 1/2' Age: 2017
LENGTH: 43"8'
STRIKER CLEVIS: 3/4 X 2 (inboard) 7/8 X 2 (crossbar) 7/8 X 3 Terminal Eye

FURLER
LOCATION:Forward Cross Bar
TYPE:Harken
UNIT CONDITION/COMMENTS
AGE: 2016

CHAIN PLATE LOCATION: Starboard side midship SIZE : 1/2 inch thick by 2 inch wide by 43 inches length 20 degree bend 34 inches up from the bottom. SECURED : 6 threw bolts 5/8 inch to a backing plate inside hull. AGE: 2016

CHAIN PLATE LOCATION: Port side midship SIZE : 1/2 inch thick by 2 inch wide by 43 inches length 20 degree bend 34 inches up from the bottom SECURED: 6 threw bolts 5/8 inch to a backing plate inside hull AGE : 2016

RUNNING RIGGING

MAINSHEET
TYPE:Dacron, Yacht Braid SIZE:5/8in LENGTH:78ft Age: 2016

JIB SHEET PORT
TYPE: Dacron,Yacht Braid SIZE: 1/2in LENGTH:34ft Age: 2016

JIB SHEET STARBOARD
TYPE: Dacron,Yacht Braid SIZE: 1/2in LENGTH:34ft Age: 2016

TRAVELR SHEET PORT & STRBD
TYPE:Dacron, Yacht Braid SIZE:3/8 LENGTH:52ft each side
Age: 2015

FURLER CONTROL LINE
TYPE:Dacron, Yacht Braid SIZE:3/8in LENGTH: 84 ft
Age: 2017

JIB HALYARD
TYPE: Dacron, Yacht Braid SIZE: 5/8in LENGTH:130'
Age:2017

MAIN HALYARD
TYPE: Dacron, Yacht Braid SIZE: 3/4 in LENGTH:150'
Age: 2016

SPINAKER HALYARD
TYPE:Dacron, Yacht Braid SIZE:5/8in LENGTH:170ft
Age: 2019

TOPPING LIFT
TYPE:Dacron, Yacht Braid SIZE:1/2in LENGTH:130ft
Age: 2016

OUTHAUL
TYPE: Dacron ,Yacht Braid SIZE: 5/8 in
LENGTH: ??
AGE: 2016

1ST REEF
TYPE: Dacron ,Yacht Braid SIZE: 5/8 in
LENGTH:48 ft
AGE: 2016

2ND REEF
TYPE: Dacron ,Yacht Braid SIZE:5/8 in
LENGTH:48 ft
AGE:2016

COMMENTS

WINCHES

MAIN SHEET WINCH
TYPE: Harken 40 SPEED: 2 Age 2017

JIB SHEET PORT WINCH
TYPE:Harken 50 SPEED: 2 Age: 2016

JIB SHEET STRBD WINCH
TYPE: Harken 50 SPEED: 2 Age: 2016

JIB HALYARD/TOPPING LIFT WINCH
TYPE: Lewmar 44 SPEED: 2 Age 2009

SPINNAKER/LADDER WINCH
TYPE: Lewmar 44 SPEED: 2 Age:2009

MAIN HALYARD TYPE: Harken 46 SPEED: 2 power ratio. Age : 2014

TRAVLER WINCH Port Side TYPE:Barient 21-33 SPEED: 2 Age: 2009

TRAVLER WINCH Starboard side TYPE: Harken 20 SPEED: 1 AGE: 2017

COMMENTS

INSPECTOR SIGNATURE, CONFIRMING INSPECTION WAS CARRIED OUT.

Untitled page

Untitled page

Please note that this checklist is a hypothetical example and provides basic information only. It is not intended to take the place of, among other things, workplace, health and safety advice; medical advice, diagnosis, or treatment; or other applicable laws. You should also seek your own professional advice to determine if the use of such checklist is permissible in your workplace or jurisdiction.