Information

  • Document No.

  • Diver

  • Conducted on

  • Prepared by

  • Location
  • Buddy if any…

00. Dive Details

  • Dive number

01. Bail out Valve and LOOP

  • BOV function - OC/CC - correct?

  • Flow - right to left / flapper valves working

  • Connected to loop hoses

02. HEAD Visual Inspection & Lubrication

  • Visually inspect all components for signs of wear and damage

  • Lubricate required o-rings and sealing surfaces

  • Sensors dry and connected

  • Place head plate with o-ring and secure screwed down

03. Scrubber components

  • Is the scrubber dry

  • How many hours has the scrubber been used for

  • Install scrubber and ensure all spacers and o-rings are in place

04. Mid-section

  • Clean and dust free

  • O-ring lubed and correct in place

  • ADV Function OK

05. Counter lung

  • Dry and clean

  • OPV function and set to dive

06. RB assembly

  • Counter lung and Scrubber in place with mid-section. Head aligned. Clips closed.OPV set to dive. O2 + DIL hoses connected.

07. Cylinders & Gases

  • Check all cylinders are correctly labelled

  • Slowly turn on O2 and Dil mix

  • Analyse onboard DIL mix % (21/00)

  • Analyse onboard O2 % (100)

  • mV DIL - sensor; 1 - 2 - 3

  • Calibrate with cap and 100% O2

  • mV O2 - sensor; 1 - 2 - 3

  • Check cylinder mount - locked and ensure they are in the correct positions

  • Check manuel add - both DIL and O2

  • Inspect all hoses

08. Connect LOOP

  • Flow right to left

  • Connect loop to head - secure screws

  • Connect BOV hose

09. Electronic Checks

  • Is handset functioning correctly

  • Are batteries working

  • Check voltage for computer and solinoid

  • Is correct gas visible

10. Pressure tests

  • Perform positive pressure test - turn off valves and breathe in to loop, close and wait 120 sec.

  • Perform negative pressure test - breathe gas from loop to completly empty, clos and wait 120 sec.

  • Check shut off valves - both DIL and O2

  • Perform pressure drop test; Turn on computers, switch to surface po2 (0.19). Open DIL and O2 valves SLOWLY. Circulate gas in loop. Close valves and ensure NO pressure drop in entire system.

11. Pre-breathing

  • Recheck settings on handset, low SP 0.5, CC/OC, BOV function.

  • Pre breathe in min. 3 min.

  • Does the ADV work

  • Confirm what position the OPV will be left in (dive)<br>

12. Last check - on site, before entering water

  • All valves open

  • Pre breathe again

  • Lead?

  • Lights and heating on board

13. Comments

  • Additional comments

  • Photographs

  • I have fully prepared and tested the unit I will be diving with

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.