Project Details

  • Project Location
  • Conducted on

  • Prepared by

  • Building Control Officer

Framing Site Inspection

Structural Steel

  • Is all structural steel installed in the correct location?

  • Is all structural steel installed the correct finish for the location/exposure?

  • Is all structural steel the correct size/profile?

  • Are all structural steel connections bolted correctly and tight?

Tie Down and Bracing

  • Tie Down - Are tie down rods installed as per structural design?

  • Tie Down - Are tie down rods all tightened up with no play?

  • Bracing - Is all sheet bracing locations installed as per structural design?

  • Bracing - Is sheet bracing nailed off with correct fixings and centres?

Timber Framing

  • Has the floor plan layout been checked against the working drawings?

  • Timber framing - Is all timber used the correct treatment and grading?

  • Wall frames - Are wall frames set out square?

  • Wall frames - Are bottom plates straight?

  • Wall frames - Are top plates straight?

  • Wall frames - Are wall frames installed plumb?

  • Wall frames - Have studs been checked for straight?

  • Wall frames - Are top plate connectors installed?

  • Wall frames - Bottom plate fixings installed as per structural engineering plans?

  • Wall frames - Are lintel sizes/fixings/stud supports and straps as as per structural engineering plans?

  • Wall frames - Are all point load stud locations/fixings correct and line up with the load it is supporting?

  • Wall frames - Are all fixings/connections correct in locations of timber beams to posts?

  • Wall frames - DPC installed under bottom plate?

  • Mid floor - Are wind beams installed as per working drawings, correct size and fixings?

  • Mid floor - Do the joist sizes and spans match the structural engineering drawings?

  • Mid floor - Are all bearers and structural joists the correct size, grade and span?

  • Mid floor - Is all mid floor hardware (joist hangers etc) installed as per working drawings?

  • Mid floor - Are the balcony joists installed with correct fall and step downs to comply with the NCC?

  • Mid floor - Has the flooring sheets been glued and fixed to the joists in the correct manner to prevent squeaks/creaks?

  • Roof framing - Is the truss spacing correct as per truss plan?

  • Roof framing - Is all truss hardware installed as per truss plan?

  • Roof framing - Are rafters the correct size and spacing?

  • Roof framing - Is the roof plane bracing installed to the roof where required, is it installed correctly?

Sign Off

  • Is Roof work complied with Building Regulations

  • Site Manager

  • Building Control Officer

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.