Clinical

Sterilization

  • Overgarment, mask, eye protection and utility gloves are worn when handling contaminated instruments

  • Date Compliance Achieved with Initials

  • Ultrasonic solution is changed daily or more frequently if needed

  • Date Compliance Achieved with Initials

  • Instrument basket or tongs are used to removed instruments from the ultrasonic cleaner

  • Date Compliance Achieved with Initials

  • Spore testing is being done weekly and recorded in log

  • Date Compliance Achieved with Initials

  • Class V integrators are available

  • Date Compliance Achieved with Initials

  • All sterilization packs removed from the sterilizer are inspected for indicator color change and to ensure no punctures.

  • Date Compliance Achieved with Initials

  • Sterilization pouches are marked with date and sterilizer #

  • Date Compliance Achieved with Initials

  • Chemical containers are covered

  • Date Compliance Achieved with Initials

Operatories

  • Are barriers being used on hard to disinfect surfaces (light handles, x-ray heads, etc.)

  • Date Compliance Achieved with Initials

  • Needle recapping device is available & being used

  • Date Compliance Achieved with Initials

  • Reusable Contaminated sharps are transported in a leak-proof, puncture resistant container

  • Date Compliance Achieved with Initials

  • Secondary container labels are in place and legible

  • Date Compliance Achieved with Initials

  • Chairside traps are changed weekly

  • Date Compliance Achieved with Initials

  • Work areas are free from tripping and falling hazards

  • Date Compliance Achieved with Initials

  • Food, beverages and make-up are not allowed in clinical areas

  • Date Compliance Achieved with Initials

PPE

  • Appropriate PPE’s are in use with patient care

  • Date Compliance Achieved with Initials

  • Overgarments are worn only in clinical areas

  • Date Compliance Achieved with Initials

  • Scrubs/over-garments are removed if contaminated

  • Date Compliance Achieved with Initials

  • Long sleeve garments are worn when there is potential for splash/splatter

  • Date Compliance Achieved with Initials

  • There are no evident areas of cross-contamination

  • Date Compliance Achieved with Initials

  • Hand hygiene is occurring before and after treating patients and wearing gloves

  • Date Compliance Achieved with Initials

  • Contaminated gloves are not to be worn when writing in charts

  • Date Compliance Achieved with Initials

  • Keyboards and computer mouse are barrier protected

  • Date Compliance Achieved with Initials

Waste Disposal

  • Are the sharps container(s) available at point of use and replaced when contents reach the full line

  • Contaminated disposable sharps are not to be transported for central disposal.

  • Date Compliance Achieved with Initials

  • Contaminated disposable sharps are not to be transported for central disposal.

  • Regulated waste is covered

  • Date Compliance Achieved with Initials

  • Non-regulated waste disposal is adequate

  • Date Compliance Achieved with Initials

Waterline Maintenance

  • Are dental unit waterlines flushed for 2 minutes at the beginning of the day and 30 seconds between patients

  • Date Compliance Achieved with Initials

  • Is a waterline maintenance product being used

  • Date Compliance Achieved with Initials

  • Are maintenance logs for dental unit waterlines present

  • Date Compliance Achieved with Initials

  • Is testing of waterlines completed every 3 months

  • Date Compliance Achieved with Initials

  • Is the OSHA/Safety Officer aware of the steps to follow for a failed waterline test

Emergency Medical Equipment and Medical Gases

  • The Spill Kit is complete

  • Date Compliance Achieved with Initials

  • All staff are informed of the location of the Spill Kit

  • Date Compliance Achieved with Initials

  • First aid supplies complete

  • Date Compliance Achieved with Initials

  • AED adult and pediatric pads are not expired, AED unit is in working order, and AED monthly inspection has been completed according to company policy and documented on www.track-pro.com? (Track-Pro for Smile Brands only)

  • Date Compliance Achieved with Initials

  • Eyewash station(s) are in place, not connected to hot water, correctly capped, labeled, and are flushed weekly

  • Date Compliance Achieved with Initials

  • Oxygen and/or nitrous tanks are secured

  • Date Compliance Achieved with Initials

  • Are all medical gas gauges in place and working properly

  • Date Compliance Achieved with Initials

  • The door for the Medical Gas closet labeled appropriately

  • Date Compliance Achieved with Initials

  • All door locks for exterior medical gas storage is in place & working correctly

  • Date Compliance Achieved with Initials

  • Emergency Oxygen Tank is secured and full

  • Date Compliance Achieved with Initials

  • Emergency Medical Kit is complete and there are no expired drugs

  • Date Compliance Achieved with Initials

Radiation

Radiation Section

  • Are shielding/lead aprons free of cracks, tears, etc

  • Order replacement

  • Are any x-ray units due for calibration/equipment performance evaluation within the next 2 months

  • Schedule a Technician (Smile Brands) or place an equipment support ticket (Midwest)

  • X-ray registration current

Analog Imaging

  • Is there analog imaging

  • Description of analog usage

  • Developer and fixer changed and logs present

  • Is there a chemical label present on the processor

  • Temperature for developer documented and logs present

  • Dark room leak test logs present

  • Darkroom requirements log present

  • Crabtree/stepwedge log present

  • Lead Foil Recycling bucket present

  • Are the film holders/aiming devices bagged and stored properly

Digital Imaging

  • Is there digital imaging for intraoral xrays

Sensor

  • Does the office use sensors?

  • Are sensors hanging properly to avoid kinks in the cable

  • Are sensors disinfected properly

  • Are barriers used on sensors

Phosphor Plates

  • Does the office use phosphor plates

  • Are barriers being used on phosphor plates

  • Are the film holders/aiming devices bagged and stored properly

Laboratory

  • Lab handpiece is sterilized/disinfected after each case

  • Date Compliance Achieved with Initials

  • Rag wheels and burs are sterilized after each case

  • Date Compliance Achieved with Initials

  • New pumice is used for every case

  • Date Compliance Achieved with Initials

  • Impressions are disinfected before being poured up or sent out

  • Date Compliance Achieved with Initials

  • Are all models labeled and stored properly

  • Date Compliance Achieved with Initials

  • Are the Lab plaster traps well sealed and changed out appropriately

  • Date Compliance Achieved with Initials

  • Is the Lab floor clear of extra plaster, storage items, etc

  • Date Compliance Achieved with Initials

Mechanical Room

  • Amalgam separator present, inspected weekly and logged

  • Date Compliance Achieved with Initials

  • Is the mechanical room free of clutter, trash and storage items

  • Date Compliance Achieved with Initials

  • Is the mechanical room free of ANY water leaks

  • Date Compliance Achieved with Initials

  • Is the mechanical room well ventilated to the outside air

  • Date Compliance Achieved with Initials

  • Is the mechanical room free of unusual smells or excessive temperature

  • Date Compliance Achieved with Initials

  • Is the mechanical room free of unusual sounds from the equipment

  • Date Compliance Achieved with Initials

Hazardous Chemicals

  • There is an SDS readily available for each hazardous substance used

  • Date Compliance Achieved with Initials

  • There is a current list of hazardous substances used in the workplace

  • Date Compliance Achieved with Initials

Facilities

Accessibility and Safety

  • Aisles and passageways are kept clear

  • Date Compliance Achieved with Initials

  • There is safe clearance for walking in aisles where motorized or mechanical handling equipment is operating (i.e., wheelchairs)

  • Date Compliance Achieved with Initials

  • Changes of elevation/direction readily identifiable

  • Date Compliance Achieved with Initials

  • There is adequate headroom for the entire length of any isle or walkway

  • Date Compliance Achieved with Initials

  • Stair rails or handrails are on all stairways having four or more risers

  • Date Compliance Achieved with Initials

  • Wet surfaces covered with non-slip materials and spilled materials are cleaned up immediately

  • Date Compliance Achieved with Initials

  • Exits are accessible without obstruction

  • Date Compliance Achieved with Initials

  • Illuminated exit signs are in working order (If applicable)

  • Date Compliance Achieved with Initials

  • Evacuation routes posted as required

  • Date Compliance Achieved with Initials

  • Lights are in working order

  • Date Compliance Achieved with Initials

  • Electrical panel/fuse box is not blocked

  • Date Compliance Achieved with Initials

  • Flexible cords and cables are free of splices or tape

  • Date Compliance Achieved with Initials

  • Extension cords have a grounding conductor

  • Date Compliance Achieved with Initials

  • All defective equipment is repaired or replaced promptly

  • Date Compliance Achieved with Initials

  • The fire extinguisher(s) is mounted and locator signs are in place (If applicable)

  • Date Compliance Achieved with Initials

  • All fire extinguishers have been inspected. The needle indicator is in the “charged” position or green zone

  • Date Compliance Achieved with Initials

  • Restrooms are clean and sanitary

  • Date Compliance Achieved with Initials

Documentation

  • State specific posters are in place

  • Date Compliance Achieved with Initials

  • Written manuals are organized

  • Date Compliance Achieved with Initials

  • Written manuals are complete

  • Date Compliance Achieved with Initials

  • All training records are maintained

  • Date Compliance Achieved with Initials

  • Has there been a transition in the Safety Officer position

  • Has the new Safety Officer completed training

  • Safety Committee meeting minutes are current

  • Date Compliance Achieved with Initials

  • Date of last Safety Meeting

Additional Information

  • Corrective Actions/ Comments

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.