Title Page

  • Site conducted

  • Conducted on

  • Prepared by

  • Location

Checklist

  • Are the post centres 1875mm?

  • Are the posts plumb (+/- 5mm)?

  • Is the fence reasonably straight?

  • Are the post footings 800mm deep by 350mm diameter?

  • Is the finished height of the post 1900mm from the finished ground level?

  • Are the steps (to accommodate land slope) leaving a reasonable gap between the fence and finished ground?

  • Has the spacer been installed in the post 1880mm down from the top of the post with 8gx50mm screw provided?

  • Have the rails been installed tongue facing up?

  • Are the rails level?

  • Is there a continuous 4mm thermal expansion gap between the rail and the post?

  • Is the “L clip” installed with the 2 8g x 25mm screws provided?

  • Are the post slot covers installed correctly?

  • Are the post caps installed correctly?

Other

  • Other

  • Other

  • Other

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.