Information
-
Document No.
-
Audit Title
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
I. GENERAL HOUSE KEEPING
-
A.) Floors, walls, windows, clean and in good repair.
-
B.) Break rooms cleaned/ disinfected daily.
-
C.) Trash containers sufficient to prevent overflow and emptied and cleaned periodically.
-
D.) All required posters and company policies in place with completed & current information.
-
E.) Aisles and hallways clearly marked and kept clear of obstacles. (1910.22)
-
F.) Cleaning supplies readily available. MSDS and CIL file electronically and in binder.
-
G.) a) Equipment properly stored and designated areas.<br> b) Unused & broken equipment properly stored and tagged "out of service" as appropriate.
-
H.) Products / supplies stored in designated areas. <br>Inventory performed and maintained.
-
I.) Outside area around building(s) clean and neat.<br>Landscaping maintained. Building in good repair.
-
J.) Proper signs posted at entrances, doorways, storage areas, maximum floor loading, etc..
-
K.) Lighting in good repair and sufficient. Bulbs replaced as needed. Light bulbs and tubes shielded as required to prevent shattering.
-
L.) Doors and locks functional and in good repair.<br>Fencing & gates working.
-
M.) Locker rooms and showers clean and in good repair. Uniforms, towels, & PPE properly stored.<br>Lockers provided and utilized.
-
N.) Smoking prohibited within building and smoking area designated.
-
O.) Work areas properly and sufficiently ventilated.
-
P.) Trucks and trailers cleaned and disinfected as needed.
-
Q.) Secondary containment/spill control pallets utilized to prevent uncontrolled releases of bulk chemicals.
-
R.) Operational and customer records purged/shredded such that only 3 years records are retained. Review records retention policy as needed.
-
S.) Floor drains are clean and free of debris. Screen netting in place to prevent large items from drains.
II. EMERGENCY RESPONSE/FIRE CONTROL & PREVENTION
-
A.) Fire extinguishers - Inspect all extinguishers and initial tags monthly. Check all units are properly hung, clean, and accessible. Place "out of service" tags on units needing repair.
-
B.) Review Emergency Contacts List and update as needed. Insure that modified list is provided to appropriate agencies. Provide emergency numbers by each phone.
-
C.) Check sprinkler system valves and sprinkler heads/pipes for damage. Inspected annually? 12" clearance for heads.
-
D.) Check all exits/non-exits for proper signage and access.
-
E.) Spill kit available and stocked with proper equipment.
-
F.) Emergency Evacuation Plan current and available.
-
G.) Emergency evacuation maps posted.
-
H.) Trained First-Aid/CPR employee on duty if shift if required.
-
I.) Fire hose connections not obstructed.
-
J.) All flammables stored in approved containers and cabinets. MSDS's & CIL available.
-
K.) Flame and spark producing operations limited to appropriate areas away from flammables/combustibles, and shields/curtains utilized.
-
L.) Emergency eyewash and shower units provided, accessible, and checked/activated weekly.
III. BASIC HEALTH & SAFETY
-
A.) New employees properly trained for specific duties.
-
B.) PPE designated, provided and utilized in accordance with completed Hazard Assessments.
-
C.) Uniforms provided and utilized.
-
D.) Employee work places clean and orderly - free of spills, oil, grease, and other hazards.
-
E.) Hand sinks available, accessible, maintained and used.
-
F.) First Aid Kit available, stocked, no outdated items in cabinet.
-
G.) Equipment guarding provided and utilized.
-
H.) All equipment working and properly maintained.
-
I.) Safety devices(I.e. lights, alarms, other signals) working.
IV. ELECTRICAL SAFETY
-
A.) Permanent wiring, boxes, switches, outlets, and lights secure, properly mounted, and free of defects. No exposed wiring
-
B.) Wiring for extension cords, portable lighting, power tools free of kinks, cuts, other damage.
-
C.) Extension cords not utilized for permanently mounted equipment.
-
D.) Breaker and fuse boxes clean, accessible, and all breakers identified.
-
H.) Portable tools and machinery properly grounded and/or double insulted. Grounding prong on plugs not removed or converted.
V. MACHINES, EQUIPMENT, & TOOLS (Operations/shop)
-
A.) Employees properly trained to utilize equipment.
-
B.) All moving parts within 7 feet of floor enclosed (fans, pulleys, etc.)
-
C.) Ladders & stairways in good repair.
-
D.) Appropriate warning signs posted on or near equipment as needed.
-
E.) Confined space program in place and current. All required signage provided.
-
F.) Necessary hand tools provided and maintained in good repair.
-
G.) Forklift training provided. Operated by certified employees only. Warning signs posted as needed. Inspections completed each shift.
-
H.) Tool rests on grinders within 1/8 of wheel & 1/4 of tongue guard.
VI. MONITORING, REPORTING & TRACKING DOCUMENTS
-
A.) OSHA 300 & 301 Log - Review. Ensure both are current.
-
B.) Training/Medical Monitoring Log. Review True North Compliance Reports. Notify employees of required training, license renewals, physicals & vaccinations, etc.
-
C.) Driver Spill Kit Checklist - check completeness
-
D.) DOT Incident reports - use Form 5800.1 . Affected facilities notified/copy to corporate.
-
E.) Shipping Documents. Review for proper completion.
-
F.) Forklift Inspections. Monitor for daily/shift change inspections.
-
G.) Weekly Inspections. Weekly inspections are being performed and filed for 1year.
-
H.) BioSystems Cart Log. Review paperwork on carts for completeness.
-
I.) a) Are rack rows full with bar in place?
-
I.) b) Does each rack have the inspection log completed and completed properly?
-
I.) c) Do all containers containing waste have caps?
-
I.) d) Are all containers labeled properly?
VII. PROGRAM SPECIFIC REVIEWS
-
A. )Driver specific issues.
-
B.) DQF completed for all drivers and signed off by SM and hiring manager.
-
C.) MVR's Review current listing of drivers and modify to obtain MVR'S for drivers operating company vehicles.
-
D.) Hours of Service. Determine compliance with 10 hour off duty, 11- hr driving/14 hr on-duty, and 60/70 hr 7/8 day limitations. Compare DMO with log books/time.
-
E.) Print and review Driver Management (JJ Keller) reports regarding violations. Disciplinary action documented for non-compliant individuals.
-
F.) DVCR's. Review to insure corrections have been made as needed.
-
G.) Driver Spill Kit Checklists - Review and replenish as needed. Perform inspections monthly.
-
H.) Ensure vehicles are labeled correctly for each state the vehicle is operated in.
-
I.) Vehicle Maintenance Files - review minimum 10% of files.
-
J.) Vehicle Emergency Response Manuals. Check for completeness & update as needed.
VIII. RADIATION MONITORING
-
A.) Review daily inspection logs to insure proper monitoring or radiation. Review policy as needed. Insure state and customer notifications are completed as required.
-
B.) Test alarm system and document all needed repairs.
-
C.) Calibrate monitors(s) annually (indicate next due date)
IX. PIT
-
A. Forklift Inspections. Monitor for daily/shift change inspections.
-
Time and date inspection completed
-
Safety manager signature
-
Manager/supervisor signature