Title Page
-
Conducted on
-
Prepared by
-
Location
Sudbury House QA Zones 1-6
Information
-
Level
-
Zone
-
Date
-
Inspector
Rolled Steel Angles
-
Are the steels in the right location?
-
Are all fixings installed?
-
Have the fixings been torqued?
-
Is the gap back to concrete more than 20mm?
-
Has Hilti firefoam been installed?
-
Has Hilti fire mastic been installed with at least 20mm depth?
-
Attach Photos of above here.
-
Add media
Hilti FireStop
-
Is the firestop tightly fitted?
-
Is the firestop sufficiently coated on all sides with hilti intumescent?
-
NO GAPS?
-
Are there 4 layers of Hilti firestop?
-
ATTACH PHOTOS
Siniat Board
-
Are the screws right depth ?
-
Have the right screws been used? (purple)
-
Are there the right amount of screws? (Every 600mm and 300mm)
-
Have the joints been sealed with intumescent?
-
Are all the boards installed and in good condition?
-
ATTACH PHOTOS
Window Installation
-
Are the window angles in the right place?
-
Is the window/lugs fully fixed ?
-
Is the glass installed?
-
Have the membranes been installed correctly?
-
Is there any damage?
Siderise Firebreaks
-
What firebreaks have been used?
- RH25
- RH50
- Siderise compression
-
Where are the firebreaks?
-
Has the Siderise app been completed?
-
YOU MUST COMPLETE THE SIDERISE APP BEFORE COVERING FIREBREAKS.
-
ATTACH PHOTOS
Bracketry
-
Have all the brackets been isolated?
-
Are the correct number of brackets installed?
-
Are all the brackets fixed properly?
-
ATTACH PHOTO
Rockwool Insulation
-
Has the rockwool been staggered?
-
Are the correct type and number of mushroom fixings installed?
-
ATTACH PHOTO
Tremco Ilbruck breather membrane
Railing and backing structure
-
Are all rails installed?
-
Are all top hats installed?
-
Are all the rails/top-hats fully fixed?
-
Are the rails in line and at the right depth for cladding?
-
ATTACH PHOTO
Cladding
-
Has the cladding been installed?
-
Is the cladding in the right line?
-
Is there any damage to the panels?
-
ATTACH PHOTO