Title Page
-
Date of Inspection
-
Inspector(s)
- Stu Wilkes
- Emma Robson - Parrott
- Jon Stevens
- Craig Palmer
- Tom Sutton
- Gareth Powell
- Colin Jackson
- Steve Shaw
-
Site Name
-
Site Manager
-
Site Address
-
Email/ Website
-
Location
Documentation
-
Ropes course construction company
- The element shall be included on the inspection certificate
- The element shall not be included on the inspection certificate
-
Date of construction
-
Date of construction
-
Inaugural inspection (Type A)
-
Plans available
-
Calculations available
-
Arborist report available
-
Construction/ installation certificates available
-
Periodical inspection paperwork available
-
Annual Arborist report available
-
Visual or operational inspection paperwork available
-
Visual or operational inspection paperwork completed
-
PPE management check
-
Operational procedures or manual check
-
Copies of paperwork taken
-
Inspection standards
- The ropes course was built prior to EN 15567: 2007 and these standards cannot be retrospective applied. All other relevant standard apply (PPE, LOLER, PUWER etc.) The inspector shall decide if the ropes course is safe for use and fit for purpose
- EN 15567 Ropes courses: Part 1 - Construction and safety and Part 2 - Operating requirements
- EN 13411 Steel wire rope terminations
- EN 795 Personal fall protection equipment - Anchors
- EN 12572 Artificial climbing structures
- ISO 4309 Cranes - Wire rope - Care and maintenance, inspection and discard
- EN 1176 Playground equipment and surfaces
- EN 795 Anchor devices
Site plan
-
Site plan
-
Site plan photo
Element
-
- Jacobs ladder
- Leap of faith
- High all-aboard
- Gladiator challenge
- Zip wire
- Giant swing
- Low ropes course
- High ropes course
- Climbing wall
- Crate stack
-
Steel frame condition
-
Pole condition
-
Wire condition
-
Guy wires condition
-
Fixings condition
-
SRB condition
-
Trolley condition
-
Connectors
-
Instructor access
-
Safety system
-
Ground surface condition
-
Sub-elements
-
Additional information
-
Pictures taken
-
Conclusion
- The element is fit for purpose
- The element is not fit for purpose
- The element is fit for purpose as long as the highlighted points are repaired or replaced within the time-frame given
-
Certification
- Stu Wilkes
- Emma Robson - Parrott
- Jon Stevens
- Craig Palmer
- Tom Sutton
- Gareth Powell
- Colin Jackson
- Steve Shaw
Statement and signature
-
Stu Wilkes
-
Any person that works on the ropes course should be trained and insured to do. This inspection report may only be reproduced in full as per the requirements of EN 15567. All inspection reports should be included in the operational documentation of the ropes course