Information
-
Document No.
-
Audit Title
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
1. Safety Administration
-
A) OH & S Act & Construction Regulations Posted
-
B) WSIB Form 82 Poster Displayed
-
C) Safety Policy Posted & Procedure Manual Available
-
D) Health & Safety at Work Poster Displayed
-
E) Workplace Violence Policy Posted
-
F) Employee Orientation Forms on File - Available Electronically
-
G) Orientation Stickers/Badges Issued
-
H) Notice of Project Displayed
-
I) Form 1000 Current and Displayed
-
J) Hazard-Warning Signs Erected Where Necessary
2. Worker Training
-
A) Safety Orientation Received/Video Viewed
-
B) WHMIS & Fall Protection Training (Proof)
-
C) Personal Protective Equipment
-
D) All Workers Have Tickets for Training
3. Emergency/First Aid
-
A) Closest Medical Centre (map displayed)
-
B) Site Emergency Numbers Posted
-
C) Emergency Evacuation Plan
-
D) Cert. First Aid/CPR Person(s) Identified
-
E) First Aid Kits Adequate & Stocked
-
G) Fire Extinguishers Available/Inspected Monthly
4. Personal Protective Equipment
-
A) Head Protection (CSA-approved - Type 1, Class E)
-
B) Foot Protection (Green Patch & Omega Symbol)
-
C) Eye Protection (riveted side shields)
-
D) Hand Protection- (Gloves appropriate for the task)
-
E) Fall Protection Harness/Lanyard/SRL
-
F) Hearing Protection at +85db
-
G) Respiratory Protection (Fit Tested)
-
H) Traffic Vest, if applicable
5. Site Access
-
A) Level Firm Ground
-
B) Walkways Unobstructed
-
C) Ramps/Stairs in Good Condition
-
D) Emergency Accessibility
-
E) Lighting - Illumination
-
F) Vehicle Parking
6. Fire Prevention
-
A) Fire Extinguisher Location Drawing
-
B) Fully Charged/Inspected Monthly
-
C) Proper Class Extinguisher Used
-
D) Building Stand Pipes/Hydrants Used
-
E) Fire Hose/Sprinkler Functional & Clear
7. Extension/Power Cords
-
A) Cords in Good Condition
-
B) No Obstruction to Walkways/Paths
-
C) Cords Strung Overhead When Possible
-
D) Cords GFCI Protected
-
E) All Prongs Entacted/Missing
8. Compressed Gas Cylinders-Gasoline/Diesel
-
A) Properly Stored/Compatibility Not Mixed
-
B) Adequately Secured When in Use
-
C) Properly Moved When Lifted
-
D) Valve Caps in Place When Not in Use
-
E) Cylinders Not Stored on Their Side
-
F) Fire Extinguisher/s Stationed Nearby
-
G) WHMIS/GHS Placarding with Contact Information Visible
-
H) Spill Kit/Containment
9. Ladders
-
A) Secured (tied-off) & 3' Above Landing
-
B) Proper Size & Type (no metal ladders)
-
C) Inspected for Defects
-
D) Being Used on a Firm Base
10. Scaffolds
-
A) Complete with Handrails & Kick Plate
-
B) Fully Decked with Proper Materials
-
C) Adequately Secured (3:1 rule)
-
D) Capable of Withstanding Load Applied
-
E) Current Inspection Tag Applied
11. Cutting/Burning/Grinding
-
A) Fire Extinguisher/s Available
-
B) Flame Arrestors at Torch End or Gauge End
-
C) Face Shields Being Used
-
D) Spark Protection/Control in Place
-
E) Proper Hot Work Permit in Place
-
F) Fire Watcher Present When Required
12. Welding
-
A) Fire Extinguisher/Watch Personnel at Work Site
-
B) Grounds Not Secured to Superstructure
-
C) Grounds Secured at Work
-
D) Adequate Ventilation Available
-
E) Flash Screens Being Used
-
F) Fire Blankets in Use (Non-Asbestos Type)
13. WHMIS Standards - Global Harmonization System
-
A) SDSs On Site File for All Products
-
B) Appropriate Hazard Labels on Containers
-
C) Employees Trained in Safe Handling
14. Hand Power Tools
-
A) Inspected Before Use
-
B) Guards Are in Place and Functioning
-
C) RPMs on Grinder are </= to Disk RPM
-
D) Power Cords Have All Prongs Attached
-
E) Tool Casing Entacted Not Damaged
-
F) Side Grip Handle Attached
15. Housekeeping
-
A) General Appearance of Site
-
B) Materials Stored Neatly
-
C) Work Areas Cleaned at End of Shift
16. Hygiene
-
A) Cleanliness of Facilities
-
B) Adequate Amount of Facilities Available
17. Cranes/Hoisting/Rigging
-
A) All Lifting Equipment Tested Yearly
-
B) Qualified Crane Operator(s) (8 Ton > Hoisting Eng. Cert)
-
C) Load Charts on Crane/Hoist
-
D) Daily Log Book Up-To-Date
-
E) Tag Lines Used On All Lifts
-
F) Competent Signal Person Used
-
G) Safety Clips in Place on All Hooks
-
H) Rigging Equipment in Good Condition
18. Excavations
-
A) Proper Shoring/Sloping
-
B) Adequate Access/Egress
-
C) Materials Stored At a Safe Distance
-
D) Trench Box Utilized as Appropriate
-
E) Established Barrier Around Excavation With Signage
-
F) Spoils not within 6' of the trench edge
-
G) Sloping/Stepping of the Earth below 4'
19. Confined Space Entry
-
A) Employees Trained Prior to Entry
-
B) Plan in Place for Each Confined Space
-
C) Coordination Document (If More Than 1 Contractor)
-
D) Air Testing Before Entry/Monitor Calibration
-
E) Emergency Plan in Place (Rescue/Equipment)
-
F) Safety Harness with Lifelines Worn
-
G) Standby Attendant Aware of Responsibilities
-
H) Proper Permit Obtained/Completed
-
I) All Sources of Energy Isolated & Locked Out
20. Powered Elevated Work Platforms
-
A) Daily Inspections Complete, Operators Manual Available (hard copy or electronically)
-
B) Workers Are Trained Prior to Use
-
C) Safety Harnesses Are Worn
-
D) Proof of Annual Inspection/Maintenance Records
-
E) Certification in Place
-
F) Rescue Preparations Considered for EWP Activities
21. Forklifts
-
A) Daily Inspection Complete, Operators Manual Available (hard copy or electronically)
-
B) Workers are Trained Prior to Use
-
C) Forks/Chains in Good Condition
-
D) Proof of Annual Inspection/Maintenance Records
-
E) Certification in Place
-
G) Lift Loading Placard Visible-Understandable
22. Propane
-
A) Handling Preformed by Trained Workers (proof)
-
B) Located 20ft From Flammable Liquid, Compressed Toxic or Corrosive Gasses
-
C) Located 3ft From Other Flammable Compressed Gases
-
D) No Ignitable Material Within 10ft ~> Mainly Trash
-
E) Locate 10ft From Public Access, 500lbs of Propane or Less
-
F) Locate 25ft From Public Access, 500lbs+ of Propane
23. Lock Out Tag Out (Last but NOT Least)
-
A) Isolation & Lock Out Methods Appropriate
-
B) Tags Visible & Complete
-
C) Numbers of Lock Consistent With # of Workers
-
D) Abandoned Lock Procedure Available/Followed
-
E) All Workers Have Certificate of Training - COQ, Apprentice Registration
-
F) ARC Flash Equipment Available and Appropriate For Voltage Rating
Non Conforming Issues - Countermeasure - Corrected By - Implementation Date
Additional Comments
-
Signature From Evaluator: