1.0 - Site Induction and Training

  • 1.1 - Is the Part 48 on file and Task Training documentation compliant?

  • 1.2 - Are the employees on shift current on Audiograms and Fit Tests?

  • 1.3 - Is there a previous reference inspection?

  • 1.4 - Have all the previous issues been addressed?

  • 1.5 - Has a site induction been given and pertinent information covered?

  • 1.6 - Does the first impression of the drill site comply with Timberline expectations?

  • 1.7 - Was there any client interaction while present on location?

  • 1.8 - Do the employees know the lock out, tag out, try out procedure?

2.0 - Fire Prevention and Flammable Storage

  • Flammables Area

  • 2.1 - Are all employees familiar with the evacuation plan in case of fire?

  • 2.2 - Is there an adequate amount of extinguishers for the work area?

  • 2.3 - Are the dates on the extinguishers compliant?

  • 2.4 - Are the extinguishers stored properly with suitable clearance?

  • 2.5 - Are the flammables stored properly with the appropriate signage?

  • 2.6 - Are the safety cans labeled properly and do they contain spark arresters?

  • 2.7 - Is the secondary containment adequate and free of combustible material?

  • 2.8 - Are the gas cylinders stored properly, labeled and tied off?

  • 2.9 - Is the housekeeping in the Flam Box or Containment compliant?

  • 2.10 - Is the Flam area free of cigarettes and rubbish?

  • 2.11 - Is the no smoking signage present, legible and visible?

3.0 - Lighting and Electrical

  • 3.1 - Is the lighting adequate?

  • 3.2 - Are the extension cords ground checked and the identifier tags on the cords?

  • 3.3 - Are all of the lights functioning?

  • 3.4 - Is the light plant door closed and both grounding rods at an adequate depth?

  • 3.5 - Is the light plant guarded properly with safe access and the jacks stands extended?

  • 3.6 - Are all electrical access points cleared with 3 feet of access?

  • 3.7 - Have the labeling requirements been met for underground GFCI's?

  • 3.8 - Are the cords or cables free of damage and exposed wiring?

  • 3.9 - Is the correct ground check tape present on all tools and equipment containing a ground?

  • 3.10 - Are the E Stops properly located and functioning?

  • 3.11 - Are the switch and outlet covers in place on the equipment?

  • 3.12 - Are we meeting the standards pertaining to Electrical?

4.0 - Vehicles

  • Vehicles

  • Vehicles Inspected

  • 4.1 - Is the parking brake set and the wheel chocks down?

  • 4.2 - Are the applicable windows and mirrors free of cracks and damage?

  • 4.3 - Is there enough clearance to walk around the vehicles including exit points?

  • 4.4 - Is there a compliant fire extinguisher properly mounted to the vehicle?

  • 4.5 - Is the cab of the vehicle compliant and is it clean?

  • 4.6 - Do all of the applicable lights function and are the lenses intact?

  • 4.7 - Are the tires, wheel assembly and lug nuts in proper order?

  • 4.8 - Is the horn functioning and working prior to starting the vehicle?

  • 4.9 - Does the vehicle have a strobe and buggy whip?

  • 4.10 - Are the seat belts in good working order with no frays?

  • 4.11 - Does the back up alarm and windshield washer fluid work?

  • 4.12 - Is the tailgate protective bar in place?

  • 4.13 - If any body damage is present is it previously documented?

  • 4.14 - Is the vehicle in good repair and running order?

  • 4.15 - Are the fluids at the appropriate levels?

  • 4.16 - Do the slip tanks have the appropriate signage and is it compliant? (Grounded)

5.0 - Work Area

  • 5.1 -Have the preshifts, blue cards or corresponding paperwork been properly filled out?

  • 5.2 - Are the ground conditions safe for the work area?

  • 5.3 - Is the ventilation adequate?

  • 5.4 - Does the crew know the emergency procedures for their job site?

  • 5.5 - Are the entryways and walkways adequate and free of tripping hazards?

  • 5.6 - Are the appropriate barricades, signage, and berms in place?

  • 5.7 - Is the work area ergonomic and user friendly?

  • 5.8 - Is there an adequate supply of labeled water and containers for each crew member?

  • 5.9 - Are all of the applicable gas monitors or lightning detectors on and in working order?

  • 7.2 - Is there a working radio on the appropriate channel within hearing distance?

6.0 - Tools

  • 6.1 - Are the hand and power tools compliant or correctly tagged out?

  • 6.2 - Are the tools properly stored and accessible to the employees?

  • 6.3 - Are the tool handles and overall care compliant?

7.0 - Work Platforms (Including the Man Basket)

  • 7.1 - Are the handrails and the work platforms adequate?

  • 7.3 - Is there a Man Basket and is it compliant?

8.0 - Housekeeping

  • 8.1 - Is the housekeeping compliant with Timberline's standard?

  • 8.2 - Is there a metal trash can with a secure lid?

  • 8.3 - Are the muds neatly stacked and LCM buckets labeled?

  • 8.4 - Is the site free of spilled material or any other substance?

  • 8.5 - Are spill clean up materials available at the site and protected from conditions?

  • 8.6 - Is a complete First Aid kit available and are the contents ready for use?

  • 8.7 - Is there an adequate supply of eyewash and is it unexpired?

  • 8.8 - Is there a complete lock box in the work area?

  • 8.9 - If the drill has a mast ladder or fiberglass ladder is it in good repair?

9.0 - Core Quality

  • 9.1 - Are the core boxes clean, legibly labeled and the blocks the same as the run log?

  • 9.2 - Is the quality of the core meeting the standards and expectations of TDI and the Client?

  • Core Boxes

10.0 - Personnel Compliance and PPE

  • Personnel Photos

  • 10.1 - Is the required PPE being utilized and the employees clean shaven?

  • 10.2 - Do the employees possess the proper PPE for mixing muds and handling chemicals?

  • 10.3 - Is there secondary PPE to replace damage to or loss of the primary PPE in use?

  • 10.4 - Is there adequate fall protection for comparable tasks in a ready condition?

  • 10.5 - If a self retracting lanyard is available is it compliant and operational?

  • 10.6 - Is the fall protection protected from weather and condition exposures?

  • 10.7 - Is auxiliary PPE available and in working order. (face shield, welding hood)

  • 10.8 - Are the employees wearing the appropriate reflective clothing?

  • 10.9 - Do the employees have a red lock and brass where applicable?

  • 10.10 - Is dual hearing protection available for all crew members at the drill?

11.0 - Mud Yard and Laydowns

  • Mud Yard , Laydown Photo

  • 11.1 - Is there a Mud Yard or Laydown to inspect?

  • 11.2 - Are the ground conditions compliant?

  • 11.3 - Is there safe access in between the stored materials?

  • 11.4 - Is the signage posted and a fire extinguisher present?

  • 11.5 - Are scaling bars present and tied off?

  • 11.6 - Is the housekeeping adequate, free of spilled material and broken bags repackaged?

  • 11.7 - Is the housekeeping compliant and loose plastic removed?

12.0 - Drill and Supporting Equipment

  • Drill Photo

  • 12.1 - Are all of the guards present and maintained? (Rod guard included)

  • 12.2 - Are all of the bolts present in the mast and guards?

  • 12.3 - Do the control panels have the appropriate levers?

  • 12.4 - Are all leaks maintained and controlled?

  • 12.5 - Is the equipment level and stabilized?

  • 12.6 - Are the appropriate pins utilized in the stiff legs, cam locks, and rams?

  • 12.7 - Is the Mud Tank compliant with a clear work platform?

  • 12.8 - Are the trash pumps labeled and in good working order?

  • 12.9 - Is the parts trailer, job box or storage containers satisfactory?

  • 12.10 - Are the whip checks or cam locks present and installed correctly?

  • 12.11 - Is the wireline free of binding and frays? (Mainline also for surface drills)

  • 12.12 - Are the sheave wheels properly guarded or compliant with height requirements?

  • 12.13 - Can the drill be isolated from energy sources? (Lock Out, Tag Out, Try Out)

  • 12.14 - Is all of the known maintenance and fabrication work up to date?

13.0 - Audiometric Testing

  • General Area

  • Control Panel

  • Power Pack, Deck Motor

  • Drill

  • Mud Tank

14.0 - Close Out

  • 14.1 - Have the findings been discussed with the Driller or Foreman?

  • Comments

15.0 - Signatures

  • Driller or Foreman Signature

  • Auditor's Signature

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.