Title Page
-
Site conducted
-
Conducted on
-
Location
-
Inspector(s)
U3 - FE - 30 / 31 - Reception
-
Is the Fire Extinguisher easily accessible and unobstructed (no debris or objects stacked in front or around it) ?
-
Are safety pins in place and intact?
-
Is the location of the extinguisher easily identifiable?
-
Are labels clear and extinguisher types and instructions can be easily read?
-
Are handles intact and not bent or broken?
-
Are pressure gauges in the green and not damaged or showing "recharge" ?
-
Are discharge hoses / nozzle in good shape and not clogged, cracked or broken ?
-
Are extinguishers free of rust or any type of corrosion build up ?
-
Has the extinguisher been turned upside down and shaken at least three (3) times ?
U3 - FE - 32 - Toilets (External)
-
Is the Fire Extinguisher easily accessible and unobstructed (no debris or objects stacked in front or around it) ?
-
Are safety pins in place and intact?
-
Is the location of the extinguisher easily identifiable?
-
Are labels clear and extinguisher types and instructions can be easily read?
-
Are handles intact and not bent or broken?
-
Are pressure gauges in the green and not damaged or showing "recharge" ?
-
Are discharge hoses / nozzle in good shape and not clogged, cracked or broken ?
-
Are extinguishers free of rust or any type of corrosion build up ?
-
Has the extinguisher been turned upside down and shaken at least three (3) times ?
U3 - FE - 33 / 34 - Business Development
-
Is the Fire Extinguisher easily accessible and unobstructed (no debris or objects stacked in front or around it) ?
-
Are safety pins in place and intact?
-
Is the location of the extinguisher easily identifiable?
-
Are labels clear and extinguisher types and instructions can be easily read?
-
Are handles intact and not bent or broken?
-
Are pressure gauges in the green and not damaged or showing "recharge" ?
-
Are discharge hoses / nozzle in good shape and not clogged, cracked or broken ?
-
Are extinguishers free of rust or any type of corrosion build up ?
-
Has the extinguisher been turned upside down and shaken at least three (3) times ?
U3 - FE - 35 / 36 - Upper Corridor
-
Is the Fire Extinguisher easily accessible and unobstructed (no debris or objects stacked in front or around it) ?
-
Are safety pins in place and intact?
-
Is the location of the extinguisher easily identifiable?
-
Are labels clear and extinguisher types and instructions can be easily read?
-
Are handles intact and not bent or broken?
-
Are pressure gauges in the green and not damaged or showing "recharge" ?
-
Are discharge hoses / nozzle in good shape and not clogged, cracked or broken ?
-
Are extinguishers free of rust or any type of corrosion build up ?
-
Has the extinguisher been turned upside down and shaken at least three (3) times ?
U3 - FE - 37 / 38 - Upper Corridor
-
Is the Fire Extinguisher easily accessible and unobstructed (no debris or objects stacked in front or around it) ?
-
Are safety pins in place and intact?
-
Is the location of the extinguisher easily identifiable?
-
Are labels clear and extinguisher types and instructions can be easily read?
-
Are handles intact and not bent or broken?
-
Are pressure gauges in the green and not damaged or showing "recharge" ?
-
Are discharge hoses / nozzle in good shape and not clogged, cracked or broken ?
-
Are extinguishers free of rust or any type of corrosion build up ?
-
Has the extinguisher been turned upside down and shaken at least three (3) times ?
Further Actions
-
Are any other issues identified? (Please give photographic evidence)
-
Inspector Sign Off
-
Inspector Sign Off