Information
-
Document No.
-
Audit Title
-
Conducted on
-
Prepared by
-
Address
-
Owner/Contact
-
Contact phone number
-
Email
Pool Maintenance
-
Temperature of the pool does not exceed 38 degrees?
-
Disinfectant dosing system type?
-
Type of treatment
Water Test
OUTDOOR POOL - Chlorination
-
1. Cyanuric acid (0-50mg/L)
-
2. pH value (7-7.8)
3. (i) Chlorine-Free/10 - with cyanuric acid
-
a) pH value (7-7.5): =>3mg/L
-
b) pH value (7.6-7.8): =>4mg/L
3. (ii) Chlorine-Free/10 - without cyanuric acid
-
a) pH value (7-7.5): =>1mg/L
-
b) pH value (7.6-7.8): =>2mg/L
-
4. Chlorine-Total/5 (0-10mg/L)
-
5. Combined Chlorine = Total Chlorine - Free Chlorine (<1mg/L)
-
6. Alkalinity (80-200mg/L)
-
7. Ozone (0mg/L) - If ozone is used in circulation system, it must not be present in the pool
-
8. Is Copper/Silver used as treatment?<br>(This includes copper sulfate or chelate)
-
9. Calcium Hardness (0-500mg/L)
OUTDOOR POOL - Bromine
-
1. Cyanuric acid (0-50mg/L)
-
2. pH value (7-7.8)
-
3. Bromine (2.25-9mg/L)
-
4. Alkalinity (80-200mg/L)
-
5. Ozone (0mg/L) - If ozone is used in circulation system, it must not be present in the pool
-
6. Is Copper/Silver used as treatment?<br>(This includes copper sulfate or chelate)
-
7. Calcium Hardness (0-500mg/L)
INDOOR POOL / SPA
-
1. Cyanuric acid (0-50mg/L)
-
2. pH value (7-7.8)
3. Chlorine-Free/10
-
a) pH value (7-7.5): =>2mg/L
-
b) pH value (7.6-7.8): =>3mg/L
-
4. Chlorine-Total/5 (0-10mg/L)
-
5. Combined Chlorine = Total Chlorine - Free Chlorine (<1mg/L)
-
6. Bromine (=>4.5mg/L)
-
7. Alkalinity (80-200mg/L)
-
8. Ozone (0mg/L) - If ozone is used in circulation system, it must not be present in the pool
-
9. Is Copper/Silver used as treatment?<br>(This includes copper sulfate or chelate)
-
10. Calcium Hardness (0-500mg/L)
Audit Complete
COUNCIL INSPECTION COMPLETE
-
Satisfactory
-
Comments
-
Please sign off this audit to complete.