Title Page
-
Project / Site name
-
Inspection Conducted on
-
Prepared by
-
Location
Lift Details
-
Lift Serial Number
-
Client Lift ID
-
Lift type
-
Number of lifts in the group
-
Rated Load
-
Number of stops
-
Number of car entrances
-
Entrance type
-
Specify
-
Lift speed
-
Specify
-
Machine room
Machinery Spaces
-
Are all machinery spaces safely accessible?
-
Provide details
-
Are all required warning and advisory notices fitted (access / first aid / hand winding etc.)
-
Provide details of any missing notices
-
Are all machinery spaces sufficiently lit (min 200lux by machinery and controllers)?
-
Provide details
-
Is the main switch for the lift accessible?
-
Provide details
-
Are all required electrical services provided?
-
Provide details
-
Are there protective isolation mats provided for work at electrical equipment (controller, drives etc)?
-
Provide details of any missing isolation mats
Controller
-
Controller make and model
-
Controller serial number
Machine
-
Type of machine
-
Provide details
-
Machine Make / Model
-
Machine serial number
-
Nominal rated current
-
Rated voltage
-
Rated power
-
RPM
Load testing
-
Empty lift current - up (A)
-
Empty lift current - down (A)
-
Empty lift voltage - up (V)
-
Empty lift voltage - down (V)
-
Balanced lift current - up (A)
-
Balanced lift current - down (A)
-
Balanced lift voltage - up (V)
-
Balanced lift voltage - down (V)
-
Full load current - up (A)
-
Full load current - down (A)
-
Full load voltage - up (V)
-
Full load voltage - down (V)
-
Does the speed remain within acceptable tolerances under all load conditions
-
Provide details
Dynamic Safety
-
Lift overspeed governor - Make / Model
-
Rated tripping speed (m/s)
-
Bi directional?
-
What method of upward overspeed protection is fitted?
-
Lift safety gear Make / Model
-
Bi directional?
-
Is there a counterweight safety gear fitted?
-
Car buffer type?
-
Provide details
-
Number of car buffers
-
Rated speed (m/s)
-
Method of protection against unintended movement from floor level
-
Provide details
DYNAMIC TESTING
-
Machine brake - Full load down
-
Machine brake - no load up
-
Machine brake - Single calliper / disk hold
-
Traction - full load down
-
Traction - empty car up
-
Unintended movement from floor (UCM)
-
Car buffer
-
Counterweight buffer
-
Car safety gear - down
-
Car safety gear - up
-
Counterweight safety gear
-
Manual lowering method?
-
Manual lowering functionality
-
Provide details
-
Automatic Rescue Device (ARD) functionality
-
Provide details
Electrical
-
Is the motor insulation resistance > 1MOhm?
-
Is the safety insultation resistance > 1MOhm?
-
Is the earth resistance <5 Ohms?
-
Does the circuit breaker trip when the furthest lock is shorted?
Lift well
-
Lift well / pit safety (stop) switch functionality
-
Provide details
-
Landing entrance electrical interlock functionality
-
Provide details
-
Landing lock bypass functionality
-
Provide details
-
Pit control functionality
-
Provide details
-
Ancillary electrical safety circuit switch (ladders / pit prop/ hatches etc) functionality
-
Provide details
-
Is the lift lighting functioning correctly (correct levels, switching etc)?
-
Provide details
-
Other notes
Car top
-
Is there an accessible safety switch on the car top?
-
Car door operator Make / Model
-
Car entrance electrical switch functionality
-
Provide details
-
Car entrance lock bypass functionality
-
Provide details
-
Car top control functionality
-
Provide details
-
Car top light functionality
-
Provide details
-
Ancillary switches functionality (hatches / ladders etc)
-
Provide details
Operation & Function testing
Car operations panel
-
Floor push functionality
-
Provide details
-
Door open push functionality
-
Provide details
-
Preference / special op switch functionality
-
Provide details
-
Signalisation functionality (voice / audible / visual)?
-
Provide details
-
Correct information displayed (Safe working load / CE / UKCA / date / manufacturer ID)?
-
Provide details
-
Emergency car lighting functionality
-
Provide details
-
Car alarm (audible and auto dialler communication) functionality
-
Provide details
-
Car operations panel EN81-70 compliance
-
Provide details
Car doors
-
Door detector edge functionality
-
Provide details
-
Door close kinetic energy <10J
-
Provide details
-
Door hold pressure ,150N
-
Provide details
Landings
-
Landing call station / DCS panel functionality
-
Provide details
-
Landing call station / DCS panel compliance
-
Provide details
-
Landing signalisation functionality (audible / visual)
-
Provide details
-
Landing signalisation compliance
-
Provide details
Clearances & Overruns
-
Are there refuge spaces in the pit and on the car top?
-
Provide details
-
Are all required refuge signs in place?
-
Provide details
-
With the car on the buffer, is there sufficient guide rail length above the counterweight?
-
Provide details
-
With the c/w on the buffer, is there sufficient guide rail length above the car?
-
Provide details
-
With the car on the buffer, is there sufficient clearance below the car to first striking point?
-
Provide details
-
With c/w on the buffer, is there sufficient clearance above the car to first striking point?
-
Provide details
Guarding and fall protection
-
Is the machine suitably guarded?
-
Provide details
-
Are all pulleys and diverters within the machinery spaces / lift well adequately guarded?
-
Provide details
-
Are all required balustrades in place on the car top?
-
Provide details
-
Are all required balustrades in place within the machine room?
-
Provide details
-
Is there adequate guarding of the counterweight within the pit?
-
Provide details
-
Are all electrical covers in place within the machinery spaces, car, well & pit?
-
Provide details
Accessibility
-
Is the lift designed to be accessible to EN81-70 compliance
-
Is the lift car size compliant with the minimum dimensions for EN81-70 compliance (w:1100 x d:1400mm)?
-
Provide details
-
Are the entrance sizes compliant with EN81-70 requirements (new well: 900mm existing: 800mm)?
-
Provide details
-
Does the car interior comply with EN81-70 requirements (handrail provision / height, LRV contrast etc)
-
Provide details
-
Do the car controls comply?
-
Provide details
-
Does the car signalisation comply?
-
Provide details
-
Do the landing controls comply?
-
Provide details
-
Does the landing signalisation comply
-
Provide details
Special functions
-
Is the lift used for firefighting / Evacuation?
-
Please specify
-
Are the lift landing entrances compliant?
-
Provide details
-
Is there a functioning & compliant fire control station on the FSAL / MEEF?
-
Provide details
-
Does the lift fire communication system function correctly?
-
Provide details
-
Is there a compliant escape hatch fitted in the car roof?
-
Provide details
-
Is all applicable equipment suitably protected against water ingress?
-
Provide details
-
Does the lift ground as required when switched to Firefighters control?
-
Provide details
-
Does the engineer's alarm sound if firefighters operation is enabled when switched to inspection control?
-
Provide details
-
Do the lift well lights illuminate upon activation of firefighters control?
-
Provide details
-
Does the lift function from the car as required under Fire / Evacuation control?
-
Provide details
-
Has a compliant secondary power supply been installed?
-
Provide details
-
Does the lift correctly switch to secondary power when required?
-
Provide details
-
Has a power status indicator been fitted adjacent to the fire control station on the FSAL / MEEF?
-
Provide details
-
Has suitable water management been installed
-
State method of water management fitted.
-
Please specify
-
Provide details
-
Other observations
Other defects / Observations
-
Please list any other defects or observations here