Title Page

  • Document No.

  • Audit Title

Location Information / Date

  • Select date

  • Substation Name

  • Add media

  • Inspection Completed By.

Inspection

  • All Signage on Outside of Fence, Appropriate and Legible ?

  • Fencing Around Substation

  • External Appearance of DPC Substation Transformer

Regulator Inspection

  • A Phase Regulator Appearance

  • A Phase Regulator Voltage

  • Tested At Control Panel

  • A Phase Regulator (Buck / Boost) and Present Position

  • BUCK / BOOST / PRESENT (Do Not Reset Drag Hands)

  • Add media

  • B Phase Regulator Appearance

  • B Phase Regulator Voltage

  • Tested at Control Panel

  • B Phase Regulator (Buck / Boost) and Present Position

  • BUCK / BOOST / PRESENT (Do Not Reset Drag Hands)

  • Add media

  • C Phase Regulator Appearance

  • C Phase Regulator Voltage

  • Tested at Control Panel

  • C Phase Regulator (Buck / Boost) and Present Position

  • BUCK / BOOST / PRESENT (Do Not Reset Drag Hands)

  • Add media

OCR (Breaker) Inspections / Counter Readings

  • #1 (North) Circuit OCR Counter Readings (A, B, C) Description of Circuit (Example Cashton South to Clinton Ridge)

  • Add media

  • #2 (East) Circuit OCR Counter Readings (A, B, C) Description of Circuit (Example Cashton South to Clinton Ridge)

  • Add media

  • #3 (South) Circuit OCR Counter Readings (A, B, C) Description of Circuit (Example Cashton South to Clinton Ridge)

  • Add media

  • #4 (West) Circuit OCR Counter Readings (A, B, C) Description of Circuit (Example Cashton South to Clinton Ridge)

  • Add media

  • All Circuits Clearly Marked and Identified

  • Add media

Battery Back/Up / Substation Transformer Inspection

  • Voltage on Battery Back/Ups for 3 Phase Gang Breakers and Form 6 's Control Panels

  • Add media

  • Appearance of Substation Service Transformer

  • Substation Service Transformer Voltage (Test at Outlet In Shack)

Thermal Imaging

  • Thermal Imaging on All VEC Connection Points (URD Terminator Connection Points)

  • Reporting of High Temperatures Recorded

  • Add media

Arrester Inspections

  • Condition of Distribution Arresters

  • Add media

Substation Appearance

  • Overall Appearance and Condition of Substation

  • Comments

  • Add media

Completion / Repairs

  • Needed Repairs/ Items Needing Attention

  • Add media

  • Add signature

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.