Title Page
-
Great Rift Valley
-
Conducted on
-
Prepared by
-
Adama, Ethiopia
-
Wind Turbine with Solar
SITE OVERVIEW
-
Road leading up to the site
-
Full Site Overview ( clear and tidy, any changes from external influences )
-
All Angles of the fence from the ground ( Clear and tidy and not over grown)
-
Area around the guy wires and anchor points ( Clear and tidy and not over grown )
-
Other images
-
Comments
BATTERY BOX
-
Entire of outside of the battery box, All angles are to be included
-
Entire inside of the battery box, All angles to be included
-
All trunking/cables leading to the tower. If the trunking is concreted , include imagery of it
-
All batteries Indicate the 3 link system
-
Battery dates
-
Are the individual battery voltages the same?
-
Arethe draws between the battery leads the same?
-
Is the voltage on the batteries the same as the App?
-
If No the the above question, specify the difference
-
What is the draw for the equipment from the batteries?
-
Are the battery terminals free from rust, corrosion, and still sealed in vasaline?
-
Other Images
-
Comments
SOLAR PANELS
-
-
Overview of the solar panels. No zoomed in images.
-
Is the wattage size correct according to the site equipment sheet?
-
Are there any negative draws of negative input voltages on the panels?
-
Are the panels clean and free of rust, corrosion and are all the connections tight?
-
Other images
-
Comments
CHARGER / CONTROLLER
-
-
Charger / controller type?
-
Is the charger unit set correctly?
-
Are the connections to the charger clean, free of corrosion and tight?
-
Other images
-
Comments
WIND TURBINE
-
-
Image of turbine not zoomed in
-
Images of each individual blade, showing the leading edge, and any damage, corrosion and discolouration.
-
Images of the stators and venturi's, showing the edges and any damage or discolouration
-
Charge controller image not zoomed in
-
Is the wind turbine serial number, type and specifications indicated correctly in the site equipment link?
-
Is the wind turbine set correctly?
-
Is the wind turbine charging correctly?
-
Other images
-
Comments
EQUIPMENT BOARD/BOX
-
-
Exterior of building/board/boxes
-
Interior of building/board/boxes. Ensure all equipment is visible.
-
What is the average amp draw between the incoming power and all the equipment? Specify highest.
-
What is the average voltage loss between the incoming voltage and the power supplies? Specify highest.
-
Is the output voltage on the camera power supplies set on 27.5 volts?
-
Are the equipment serial numbers and QR code numbers correct according to the site equipment sheet?
-
Are the system control load and brake relays working correctly?
-
Is the data logging computer set up clean and tidy and working?
-
Other images
-
Comments
CAMERA
-
-
Is the serial number and the QR code correct according to the site equipment list?
-
What is the camera draw?
-
Image of the camera
-
Image of the camera stand
-
Are the cameras free from rust and corrosion?
-
Other images
-
Comments
LINKS REPEATERS AND CONNECTORS
-
-
All link connectors
-
All links secured tightly?
-
All links working and have good signal?
-
Are all Connections in good condition, tight and free from corrosion?
-
Other images
-
Comments
SECURITY CAMERA
-
-
Image of the security camera
-
Is the security camera lens cleaned, positioned correctly and above 3m?
-
Are all cameras in good condition and free from corrosion?
-
Other images
-
Comments
WEATHER STATION
-
-
Image of the weather station display screen, anemometer, weather vane, and station
-
Has the weather station been calibrated correctly? (Longitude, Latitude, Elevation, Time, Date, Board rate, Cup size, etc)
-
Has the station solar panel been cleaned?
-
Is the rain collector area clean and clear?
-
Has the anemometer been serviced? (Cup and direction indicator removed, bearings cleaned and positioned back correctly)
-
Are the weather station unit and the anemometer just above the tree line?
-
Are there any signs of rust or corrosion?
-
Other images
-
Comments
LATTICE GUYS / FLANGES / WEBS
-
-
Are the nuts and bolts in good condition?
-
Random imagery of nuts and bolts on the tower, minimum 3 sections
-
Are the guy wire points on the tower in good condition and free from corrosion?
-
If No to above, please specify and attach images to other question below
-
Imagery of the base of the tower, base and webs
-
Is there a fall arrest installed?
-
Are the aircraft/navigation lights fitted and working?
-
Are there any signs of rust or corrosion?
-
Other images
-
Comments
TOWER/LOOKOUT PLATFORM
-
-
Are the nuts and bolts still in their paint aligned position and still in good condition?
-
If No to above, please specify and attach imagery to other question below
-
Random imagery of nuts and bolts on the tower, and the service platform
-
Imagery of doors, inclue hinges and locking mechanisums
-
Imagery of the Cabin area and Roof
-
Are the guy wire points on the tower in good condition?
-
If No to above question, please specify and include imagery in other question below
-
Imagery to the base of the tower
-
Are there any signs of rust or corrosion
-
Other Images
-
Comments
ANODES
-
-
Are the Anodes functioning correctly?
-
Imagery of all the Anodes
-
Other Images
-
Comments
EARTHING
-
-
Is there a supressor for each piece of equipment in the Tower? ( Cameras Links etc)
-
Are there suppressors, camera stands, link brackets, and Tower Equipment boxes Earthed to a single point on the Tower which is at least 2m below the last link?
-
Is the Lightning/earth spike at least 3m above the top of the camera?
-
Is the equipment in the equipment box eatrhed to a single point in the box, which then has an external point that goes down to the same point as the other equipment?
-
Has the all earth cable connections point been cleaned, ie metal on metal contact with vasaline to stop corrosion?
-
Have the lightning rod spike tips cleaned to expose metal better?
-
Are all earth connections rust and corrosin free?
-
Do all the tower anchor points have earth straps/cables going into the ground?
-
Are all the guy wires earthed to the ground?
-
Are all the battery boxes earthed to the ground with an earth rod?
-
Attach imagery for all the above mentioned points ( Suppressors, brackets, camera stands, equipment box. earth point on tower, tower base earthing, guy wire earthing and battery box earthing)
-
Other Images
-
Comments
DATA LOGGING
-
-
Is the data logging system running correctly?
-
Are there any danger over specification flags in the data logging history?
-
Is the hard copy Back-up SD/USB in tact?
-
Take a back-up
-
OVERALL
-
-
Comments