Information
-
Building / Client site
-
Conducted on
-
Prepared by
Lighting
-
All lights/bulbs/lamps checked and none needs replacement?
-
Checked any luminaires that have transformers, control gear or accessories, such as spread lenses, glare baffles or color filters?
-
Exterior lights and cables aren’t torn; all screws and hardware in place and working?
-
All exit lighting are properly installed and functioning?
-
All interior lighting are properly installed and functioning?
-
All exterior lighting are properly installed and functioning?
-
Additional and or Final Comment:
Electrical
-
Have you changed batteries in smoke and carbon monoxide detectors, flashlights and test instruments?
-
Timers and photocells are functioning correctly?
-
Cover plates have no cracks and have proper tightness?
-
All exhaust fans are clean?
Safety
-
Checked inventory and restocked all first aid kits?
-
Checked eyewash bottles and stations?
-
Safety signs and equipment labels are in good condition?
-
Respirators inspected and cleaned?
-
Fall protection harnesses and kits inspected?
HVAC
-
Air intake cleaned (as needed)?
-
Changed all air filters (as needed)?
-
Blower motors in operation have no excessive noise or vibration?
-
Cleaned motors and ductwork (as needed)?
-
Condensate drain pan has proper drainage?
-
Checked the flexible duct connectors?
-
Guards and panels are secured and not loose?
-
All electrical hardware and connections are in good condition?
-
Controls and equipment tested and safe?
-
Interior unit operating properly?
-
Condenser motor bearings have no excessive noise or vibration?
-
Inspected the condenser air intake, discharge, and coil?
-
All refrigerant piping and insulation in good condition?
-
Guards or access panels secured and not loose?
-
Exterior unit in good operation?
-
Inspected compressed air lines regularly? No leaks in piping, tubing or fittings?
-
Replaced or cleaned air filter elements at least quarterly, or as necessary depending on the application?
-
Oil levels on air compressor pumps monitored and replaced (as necessary depending on usage)?
Building Interior
-
Floors, ceilings, and walls show no evidence of deterioration?
-
REFERENCE: Floors, ceilings, and walls show no evidence of deterioration
[This is an example of how you can use iAuditor to include best practice reference images in your templates to assist with inspections] -
No visible signs of leaks?
-
Inspected and found no hazards (electrical, mechanical, structural, physical, tripping, etc.)?
-
Faucets, toilets, and showers are operational and in good working condition?
-
Smoke and carbon monoxide detectors tested and working?
-
Fire alarm system tested and working?
-
Firefighting equipment in good condition?
-
All doors in proper operation; exits are not obstructed?
-
Door locks and closures in good condition?
-
Work areas and walkways are properly marked?
-
No accumulation of trash in storage areas?
-
No evidence of insect infestation?
-
Cart casters show no wear and that shelving is properly labeled, organized, and secured?
Building Exterior
-
Paint and walls in good condition?
-
No broken windows or doors?
-
All railings in good condition?
-
No plants growing on the building or its foundation?
-
Roof is cleaned (as needed)? Be careful when working in high places; employ adequate fall protection.
-
Cleaned roof drains and gutters (as needed)? Tested drains and downspouts by flushing them with water?
-
Roof in good condition?
-
Gutters have adequate anchoring and tightened if necessary?
-
Inspected the stack and all roof penetrations?
-
No plant life growing on the roof? (remove if any)
-
No debris found? (clean if any)
-
No broken glass and debris on the grounds?
-
Sidewalk in good condition?
-
Driveway and parking area in good condition?
-
Storm water drains in good condition?
-
Plants and lawns in good condition?
-
Trees in good condition; no branches are about to fall?
-
Area around the dumpsters are clean?
-
Fencing in good condition?
Plumbing
-
Plumbing inspected at least annually? No leaks or unusual noises?
-
Domestic water booster and circulation pump systems require bearing lubrication at least annually; no leaks on couplings?
-
Are domestic water heaters and boilers fire-tested periodically? Used flue-gas analysis to adjust the flue draft and combustion air input to help optimize efficiency?
-
Remote drinking water chillers need condenser fan motor bearings lubricated annually. All contacts show no wear and pitting? Ran system control tests?
-
Pumped down the system and removed the refrigerant according to manufacturer instructions? Drained and replaced oil in the compressor oil reservoir, including filters, strainers and traps?
-
Sump and sewage ejection pumps are functioning properly (and replaced on an as-needed basis)? Exposed pumps lubricated (annually)?
Completion
-
Name and signature: