Has the Sub been through a pre installation meeting.?
-
Did the sub have shop specific shop drawings?
-
Is 3rd party required?
-
What scope of work?
-
Does the submittal reflect the specs.
PENTA QA/QC: ISAAC ZAMORA
SHEETING AND FASTNERS
-
Is the sub contractor following there submitted QAQC plan.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
What is the wall finish, if tile is the substrate a approved tile backer board?
-
Is the area clean and free of any cureing agents?
-
-
Are the drains in correctly ?
-
Does the substrate slope to drain?
-
Are all but joints tight?
-
Are the screw patterns good.
-
Are there overdriven screws?
-
Any broken corners or holes in sheeting?
-
Is the wall straight?
-
All all screw heads covered with thinset?
-
(Shower installation only)Was the sheeting sil and corners embedded in sika 1a?
-
Is there a min 1/8 gap at the bottom of sheeting?
Waterproofing/Thinset
-
Is the subcontractor installing in accordance with manufacturer installation instructions.
-
What material is being installed?
-
Has is the material been approved per specs?
-
Is sub contractor installing waterproofing proofing at proper mils?
-
Has a field addition test been preformed prior to start of installation?
-
Is floor prep, is the substrate contaminate and moisture free concrete ready for waterproofing?