Back Of Site
Power Generation.
-
Power Generation Method.
-
Kwh from power meter in Switch Gear.
-
Photo's of total Kwh and Max Kwh from city Electric Meter (Next to Main Transformer)
Power Plant.
-
All Plastic Crosses are installed in required locations
-
Plower lock connected to Generators are Supported and there is no weight on the connectors
-
Earth Bonding between Generators is secure and connected correctly.
-
Communications Cables are supported and show no signs of damage.
-
Load Share Cables are supported and show no signs of damage.
-
Any Visible Signs of damage to cables passing through Truck Bed.
-
If Installed, Grounding on Shore Power Enclosure is Connected and Tight.
Switch Gear.
-
Total Kwh from electric meter at Main Site transformer.
-
Have Any Generator Input Circuit Breakers Tripped.
-
Have any outgoing, Circuit Breakers Tripped.
-
Have any DC Circuit breakers or fuses Tripped in the Control Panels.
-
DC Battery Charger is online and Operational.
-
Have any Circuit Breakers Tripped in the 120/240 Switch Board.
-
Shunt Trip UPS is Online and Operational.
-
High Resistance Grounding System is Clear of Alarms.
-
External indication Beacon Is operational. (Green light on)
-
All Lights are operational (Interior and Exterior)
-
Power lock connected to switch Gear are Supported and there is no weight on the connectors
-
Any Visible Signs of damage to cables on the ground.
-
Main Ground bonding Connections On switch Gear are Tight and Main ground link is connected and locked.
-
Grounding connections on main Grounding Triangle are tight and secure.
-
Bonding between generators, Fuel Tank and switch Gear are all connected and tight.
Show and Service Transformers.
-
ADA Cable ramp is in good condition and cables are installed correctly
-
Any Visible Signs of damage to cables.
-
Any Visible signs of Damage to the transformers
-
Power Lock Connectors are in good condition and locking pins are correct position on transformer (Primary and Secondary Side)
-
Have any Circuit breakers tripped (Primary Side)
-
Have Any Circuit Breakers Tripped (secondary Side and Artistic Tour Pack)
-
All GFCI and Bender Modules are clear of faults and showing Zero on the Display.
-
All Circuit Breaker Covers are closed and latched. (Transformers and Tour Pack)
-
Pin and Sleeve Lock rings are locked and sealed. (Transformer and Tour Pack)
-
All Grounding connections are connected and secure.
Staff Sanitary (22)
-
Plastic Cross are installed at all power lock connections along Cable run.
-
Power Lock Connectors are in good condition and locking pins are correct position along cable run.
-
Power Lock Connectors are in good condition and locking pins are correct position on Truck Input
-
Slings Installed to remove weight from power lock connectors
-
Any Visible Signs of damage to cables.
-
Pin and Sleeve Lock rings are locked and sealed.
-
All Grounding Lugs are connected and secure.
-
Heater Thermostats are set correctly and covers locked.
-
Restroom Exhaust fans operational.
-
Exhaust fan in Service room is operational.
-
Have any Circuit Breakers Tripped on the Electrical Panels.( including the outside laundry)
-
All Lights are operational.( inside and outside)
Kitchen.
-
Plastic Cross are installed at all power lock connections along Cable run.
-
Power Lock Connectors are in good condition and locking pins are correct position along cable run.
-
Power Lock Connectors are in good condition and locking pins are correct position on transformer and tour pack and Kitchen Switch Board.
-
Any Visible Signs of damage to cables.
-
Have Any Breakers Tripped on the Transformer Primary side.
-
Have any Breakers tripped on the transformer Secondary side.
-
Have any breakers tripped on the 60A or 30A distribution.
-
All GFCI and Bender Modules are clear of faults and showing Zero on the Display or a green light on the outlet.
-
All Circuit Breaker Covers are closed and latched.
-
Pin and Sleeve Lock rings are locked and sealed.
-
All Grounding connections are connected and secure.
-
Have any Circuit Breakers Tripped on the Internal Electrical Panels. (Reefer Truck , Kitchen Truck, Breakfast Table and Desert fridge/under counter fridge freezer)
-
All emergency Lights and signs are operational and have been tested with loss of power or test magnet.
Offices.
-
Plastic Cross are installed at all power lock connections along Cable run.
-
Power Lock Connectors are in good condition and locking pins are correct position on transformer.
-
Power Lock Connectors are in good condition and locking pins are correct position along cable run.
-
Power lock between Transformer and Tour Pack are in good condition and all locking pins are in the correct position.
-
Any Visible Signs of damage to cables.
-
Have Any Breakers Tripped on the Transformer primary side.
-
Have any breakers tripped on the Transformer secondary side.
-
Have any breakers tripped on the Tour Pack
-
All GFCI, RCD and Bender Modules are clear of faults and showing a green light on the outlet or zero on the display.
-
All Circuit Breaker Covers are closed and latched.
-
Have any Circuit Breakers Tripped on the Internal Electrical Panels.
Site Shop.
-
Plastic Cross are installed at all power lock connections and pin and sleeve along Cable run.
-
Power Lock Connectors are in good condition and locking pins are correct position along cable run. (if 480v Tour Pack is Used)
-
Any Visible Signs of damage to cables.
-
Have Any Breakers Tripped on the Tour Pack (if 480v Tour pack is used)
-
Have any breakers tripped on the transformer primary side.
-
Have any breakers tripped on the Transformer secondary side.
-
All RCD and Bender Modules are clear of faults and showing Zero on the Display or a green light on the outlet
-
Pin and Sleeve Connectors are in good condition and locking rings are locked and sealed on transformer.
-
Pin and Sleeve Lock rings are locked and sealed.
-
Have any Circuit Breakers Tripped on the Internal Electrical Panels. (75 and 80)
-
All Circuit Breaker Covers are closed and latched on External Distribution.
-
All Grounding Connections are connected and secure.
Water Station
-
Is a transformer being used.
-
Pin and sleeve connections on transformer are tight and sealed
-
Have any breakers on the transformer tripped
-
Have any GFCI on the transformer tripped
-
All Covers are locked and secure
-
Transformer is in good condition
-
Cables for the transformer are in good condition
-
Earthing Connections are tight and secure
-
Pin and sleeve for 60A distro is in good condition and connected correctly
-
Have any GFCI or Breakers Tripped on the 60A Distro.
-
All pin and sleeve are connected correctly and locking rings are tight and secure.
-
All pin and sleeve connected to the pumps are connected correctly and locking ring is tight and secure.
-
Light and electrical equipment is operational in the water station.
Technical. (54)
-
Plastic Cross are installed at all pin and sleeve connections along Cable run.
-
Pin and Sleeve Connectors are in good condition and locking rings are locked and sealed.
-
Any Visible Signs of damage to cables.
-
Have any Circuit Breakers Tripped on the Internal / External Electrical Panel or distribution.
-
All GFCI and Bender Modules are clear of faults and showing Zero on the Display.
-
All Circuit Breaker Covers are closed and latched on External Distribution.
-
All Grounding Lugs are connected and secure.
Temps Tent / Cardboard Compactor
-
Temps Tent Distro In good condition.
-
Have any Circuit Breakers tripped on the 30A distort Temps Tent.
-
30A pin and sleeve is connected correctly and locking ring is locked and secure.
-
All GFCI Modules are clear of faults and showing a green light on the outlet
-
Circuit Breaker cover is locked and secure
-
Temps tent work light is on and working.
-
Any Visible Signs of damage to cables in the temps tent
-
Compactor Pin and Sleeve is connected, Lock ring is locked and secure.
-
Any Visible Signs of damage to cables in the compactor area.
-
Compactor tent work light is on and working.
Stage Left.
-
ADA Cable ramp at Door 8 is in good condition and cables are installed correctly
-
All pin and sleeve connectors are on plastic cross and lock rings are tight and sealed.
-
All weatherproof Cables (Yellow Plugs) are sealed correctly.
-
Bathroom non weather proof plugs are covered and not exposed to the weather.
-
Have Any Circuit Breakers Tripped on Bathroom 60A Distro.
-
All GFCI and Bender Modules are clear of faults and showing Zero on the Display or a green light on the module.
-
All Circuit Breaker Covers are closed and latched.
-
All wall light and tunnel light weatherproof Cables (Yellow Plugs) are sealed correctly.
-
Any Visible Signs of damage to weather proof cables.
-
Power Lock cables and Connectors are in good condition and locking pins are correct position along the Big Top.
-
Plastic Cross are installed under all power Lock Connections around the big top.
-
Any Visible signs of Damage to power lock cables or connectors.
Front Of House
Stage Left.
-
All Plastic Crosses are installed in required locations
-
ADA Cable ramp is in good condition and cables are installed correctly.( Wing Door)
-
Any Visible Signs of damage to cables.
-
Power Lock Connectors are in good condition and locking pins are correct position along cable run.
-
Power Lock Connectors are in good condition and locking pins are correct position on transformer.
-
Have Any Circuit Breakers Tripped on the Transformer.
-
All GFCI and Bender Modules are clear of faults and showing Zero on the Display or a green light on the outlet.
-
All Circuit Breaker Covers are closed and latched.
-
Pin and Sleeve Lock rings are locked and sealed.
-
All Grounding connections are connected and secure.
-
ADA Cable ramp is in good condition and cables are installed correctly.( Main Entry)
-
60A and 30A distribution Behind the Swing Set are in good condition.
-
Have any Circuit breakers tripped on the distribution behind the swing sets?
-
All GFCI and Bender Modules are clear of faults and showing Zero on the Display or a green light on the outlet for the distribution behind the swing sets.
-
Any visible damage to cable or plugs/ connectors behind the swing sets.
Mast 6
-
Cable mat is in good condition and cables are installed correctly
-
Any Visible Signs of damage to cables.
-
All Grounding connections are connected and secure.
Mast 6
-
Cable mat is in good condition and cables are installed correctly.
-
Any Visible Signs of damage to cables.
-
All Grounding connections are connected and secure.
SMB Transformer (No Mans Land) ,Video Wall and Wings SR and SL
-
30 Amp Distro in each wing is in good condition.
-
Have any breakers tripped on the wing distros.
-
All GFCI Modules on wing distros are clear of faults.(green light on outlet is on)
-
Plastic Cross are installed at all power lock connections along Cable run in no mans land.
-
Power Lock Connectors are in good condition and locking pins are correct position along cable run.
-
Power Lock Connectors are in good condition and locking pins are correct position on transformer.
-
All Grounding connections are connected and secure.
-
Any Visible Signs of damage to cables.
-
Have Any Breakers Tripped on the Transformer.
-
All GFCI and Bender Modules are clear of faults and showing Zero on the Display or a green light on the outlet.
-
All Circuit Breaker Covers are closed and latched on the transformer.
-
Pin and Sleeve Lock rings are locked and sealed on the transformer.
-
Have Any Breakers Tripped on the external Distribution ( 60A distro under SMB)
-
All GFCI and Modules are clear of faults on the external Distribution.
-
30A distro on top of battery pack is in good condition.
-
Have any Breakers tripped on 30A distro on top of Battery Pack.
-
All GFCI and Modules are clear of faults on the 30A distro on the battery pack.
-
All connections on Battery Pack are connected correctly (emergency lights, mast lights, Work Lights)
-
Socapex breakouts are connected correctly to battery pack and general power is connected to the 30A disto on top of battery pack
-
60A pin and sleeve to the battery Pack is connected and secure
-
Emergency Exit signs are operational and LED lights come on when test button is pressed.
-
Exterior mast light timer is showing correct time and set for the correct hours of operation.
-
All Work Lights Are operational
-
60A pin and sleeve is connected to the AV Rack correctly.
-
Any Visible Signs of damage to cables in this area.
Merchandise.
-
Cable ramp is in good condition and cables are installed correctly
-
Any Visible Signs of damage to cables.
-
30A and 60A distros are in good condition.
-
Have Any Circuit Breakers Tripped.
-
All GFCI Modules are clear of faults.(green light on outlet is on)
-
All Circuit Breaker Covers are closed and latched.
-
Pin and Sleeve Lock rings are locked and sealed.
-
Exterior light timer is showing correct time and set for the correct hours of operation.
Front of Site (Public Area)
-
All Plastic Crosses are installed in required locations
-
All Wall Lights are installed correctly and are upright.
-
Any Visible Signs of damage to cables.
-
All weatherproof Cables (Yellow Plugs) are sealed correctly.
-
Any Visible Signs of damage to weather proof cables.
-
Arch Battery Condition.
-
Does the Mains power charger need to be plugged in to charge Arch Batteries.
-
Arch Solar Panels are charging battery's. Check indicator lights in control panel. (2 green leds on left side of controller)
-
Arch Timer is set to correct time and hours of operation are set correctly.
Box Office.
-
All Plastic Crosses are installed in required locations along the cable run.
-
Pin and Sleeve cables are connected correctly and in good condition and lock rings are tight and sealed.
-
Pin and Sleeve cables are connected to the box office correctly and lock rings are tight and sealed.
-
Any visible damage to pin and sleeve cables.
-
All external LED lights on box office are operational.
-
All window lights are operational.
-
All Inside window lights are operational.
-
Have any Circuit Breakers Tripped.(internal Switch Boards)
-
Have any 24Vdc Fuses blown.(all window lights)
-
General lighting in box office is operational.
Stage Right Swing Set Distribution.
-
ADA Cable ramp is in good condition and cables are installed correctly.( Main Entry)
-
60A and 30A distribution Behind the Swing Set are in good condition.
-
All GFCI and Bender Modules are clear of faults and showing Zero on the Display or a green light on the outlet for the distribution behind the swing sets.
-
Have any Circuit breakers tripped on the distribution behind the swing sets?
-
Any visible damage to cable or plugs/ connectors behind the swing sets.
-
All Plastic Crosses are installed in required locations.
-
Power Lock Connectors are in good condition and locking pins are correct position along cable run.
-
Power Lock Connectors are in good condition and locking pins are correct position on transformer.
-
Have Any Circuit Breakers Tripped on the Transformer.
-
All GFCI and Bender Modules are clear of faults and showing Zero on the Display or a green light on the outlet.
-
All Circuit Breaker Covers are closed and latched.
-
Pin and Sleeve Lock rings are locked and sealed.
-
All Grounding connections are connected and secure.
-
ADA Cable ramp is in good condition and cables are installed correctly.( Wing Door)
-
Any Visible Signs of damage to cables.
Stage Right
-
ADA Cable ramp at Door 7 is in good condition and cables are installed correctly
-
All pin and sleeve connectors are on plastic cross and lock rings are tight and sealed.
-
All weatherproof Cables (Yellow Plugs) are sealed correctly.
-
Bathroom non weather proof plugs are covered and not exposed to the weather.
-
Have Any Circuit Breakers Tripped on Bathroom 60A Distro.
-
All GFCI and Bender Modules are clear of faults and showing Zero on the Display or a green light on the module.
-
All Circuit Breaker Covers are closed and latched.
-
All wall light and tunnel light weatherproof Cables (Yellow Plugs) are sealed correctly.
-
Any Visible Signs of damage to weather proof cables.
-
Power Lock cables and Connectors are in good condition and locking pins are correct position along the Big Top.
-
Plastic Cross are installed under all power Lock Connections around the big top.
-
Any Visible signs of Damage to power lock cables or connectors.
Artistic
-
All pin and sleeve cables locked and sealed correctly.(on tour pack and on distro's)
-
All pin and sleeve connections on plastic cross where required
-
Have any breakers tripped on the external 60A distros.
-
GFCI and Bender modules are clear of faults and showing zero on the display or a green light on the module
-
All cables pluged in to the 60A distros are weather proof cables or pin and sleeve.
-
Have any GFCI or breakers tripped on the 30A distros in Artistic (Red Carpet, 2 In male Lodge Area, Wardrobe, Shoe Tent, Drying Area and P-Med)
-
All fluorescent tube's working ( wardrobe area and shoe tent)
-
Chicken Warmer (Artist Heater) Operational, timer set to correct time and Operation time is correct for on and off.
-
60A pin and sleeve is connected correctly to battery pack.
-
All cables are connected to the battery pack correctly.
-
Exterior mast lights timer is showing correct time and set for the correct hours of operation.
-
Emergency Exit signs are operational and LED lights come on when test button is pressed.
Big Top- Back Stage
-
Pin and sleeve connected to 30A distro correctly.
-
Have any GFCI or breakers tripped.
-
Is Distro in good condition.
-
Any Signs of cable damage to any cables in this area.
-
Back Stage Work lights are operational.
Big Top
-
Ada Cable ramp Under bleacher at door 7 is in good condition.<br>
-
Power Lock are connected to the fridge correctly and locking pins are in correct position.
-
Socapex are connected correctly to the fridge all locking rings are tight.
-
Pin and sleeve are connected correctly to the fridge and locking rings are tight
-
Harting Connector is Connected correctly and locking handle is secure.(Cupola Fan Control Case on the rear)
-
Cupola Fan Control System Is powered and operational No RCD, Breakers or TOL have tripped.
-
Both Twist Lock for the emergency Light Trigger are connected correctly.
-
All 6 red indicators are lit on the Emergency Light Trigger.
-
Link Cable From The Emergency Light Trigger to The fridge is installed and connected
-
Green operation light is Lit indicating Emergency Light Trigger is connected.(on Fridge)
-
Emergency Light ByPass Plug is not connected and hanging in Fridge.
-
External Mast Light and wall Light timer are set to the correct time and hours of operation is correct.
-
Door 7 Distro is connected correctly All connections are tight and plugs are not loose.
-
Door 7 tunnel lights GFCI has not tripped and is operational
-
Mast 1 Battery Pack Operational Power light is on and Indicator for charge is on.
-
Door 5 Distro is connected correctly All connections are tight and plugs are not loose.
-
Door 5 tunnel lights GFCI has not tripped and is operational
-
Has the Exterior wall Lights GFCI at Door 5 Tripped.
-
Door 3 Distro is connected correctly All connections are tight and plugs are not loose.
-
Door 3 tunnel lights GFCI has not tripped and is operational
-
Mast 2 Battery Pack Operational Power light is on and Indicator for charge is on.
-
Door 1 Distro is connected correctly All connections are tight and plugs are not loose.
-
Door 1 tunnel lights GFCI has not tripped and is operational
-
Door 2 Distro is connected correctly All connections are tight and plugs are not loose.
-
Door 2 tunnel lights GFCI has not tripped and is operational
-
Door 4 Distro is connected correctly All connections are tight and plugs are not loose.
-
Door 4 tunnel lights GFCI has not tripped and is operational
-
Mast 4 Battery Pack Operational Power light is on and Indicator for charge is on.
-
Door 6 Distro is connected correctly All connections are tight and plugs are not loose.
-
Door 6 tunnel lights GFCI has not tripped and is operational
-
Has the Exterior wall Lights GFCI at Door 6 Tripped.
-
Door 8 Distro is connected correctly All connections are tight and plugs are not loose.
-
Door 8 tunnel lights GFCI has not tripped and is operational
-
Mast 3 Battery Pack Operational Power light is on and Indicator for charge is on.
-
Door 8 Handicap Tunnel Lights and Exit Sign Operational
-
Door 8 Tunnel Lights and Exit Sign Operational
-
Door 6 Tunnel Lights and Exit Sign Operational
-
Door 4 Tunnel Lights and Exit Sign Operational
-
Door 2 Tunnel Lights and Exit Sign Operational
-
Door 1 Tunnel Lights and Exit Sign Operational
-
Door 3 Tunnel Lights and Exit Sign Operational
-
Door 5 Tunnel Lights and Exit Sign Operational
-
Door 7 Tunnel Lights and Exit Sign Operational
-
Door 7 Handicap Tunnel Lights and Exit Sign Operational
-
All Section Signs Operational
-
All Sponsor Banners Operational
-
When Emergency Lights Triggered Cupola Emergency Light LED Strips Operational
-
When Emergency Lights Triggered All exit signs stay on and all LED flood lights come on and are operational
-
All Mast work Lights Are operational
-
All Cupola Lights Are operational