30A/50A Power Inlet Install
-
Is the inlet in installable condition?
-
Is the outer jacketing stripped back approximately 1.5"?
-
Is the inner conductor jacketing stripped back approximately .75"?
-
Are the load, neutral, equipment ground wires in the proper location?
-
Are the load, neutral, equipment ground wires seated properly within lug?
-
Does the conductor wire jacketing land under the terminal?
-
Is bare copper from the conductor wire showing above the opening flange?
-
Are the lugs torqued to the proper install torque rating? 30A Inlet - 20IN.LBS. / 50A Inlet - 35IN.LBS.
-
Was the power inlet secured to unit w/o damage to housing?