Title Page

  • Conducted on

  • Prepared by

  • Location
  • Superintendent Name

  • Project Manager Name

Jobsite Inspection

Job trailer or construction office

  • Does the job have the required safety essentials? AWAIR & RTK Programs?

  • Are weekly toolbox talks being conducted?

  • Are construction barricades and construction signage erected to warn of potential hazards?

  • Is there a heater in the portable toilet?

Concrete/Masonry (Subpart Q - 1926.700)

  • Concrete/Masonry (Subpart Q - 1926.700)
    https://www.ecfr.gov/cgi-bin/retrieveECFR?gp=1&SID=b82849dbe6eb55c8710eca668249ba2f&ty=HTML&h=L&mc=true&r=SECTION&n=se29.8.1926_1700

  • Are all impalement hazards eliminated?

  • Are precautions being taken when employees are exposed to silica? How are you controlling the exposure?

  • Is the guard on the concrete mixer closed?

Confined Space (Subpart AA - 1926.1200)

  • Confined Space (Subpart AA - 1926.1200)
    https://www.ecfr.gov/cgi-bin/retrieveECFR?gp=1&SID=b82849dbe6eb55c8710eca668249ba2f&ty=HTML&h=L&mc=true&n=sp29.8.1926.aa&r=SUBPART#se29.8.1926_11200

  • Has the atmosphere been tested for toxic gasses? (Carbon monoxide, etc.)

  • Is a permit required before entry into the confined space?

  • Have all employees entering the confined space been trained?

Cranes (Subpart CC - 1926.1400)

  • Cranes (Subpart CC - 1926.1400)
    https://www.ecfr.gov/cgi-bin/retrieveECFR?gp=1&SID=b82849dbe6eb55c8710eca668249ba2f&ty=HTML&h=L&mc=true&r=SECTION&n=se29.8.1926_11400

  • If performing craning operations, is your operator certified?

  • Has a daily inspection been performed on the crane and is there an annual inspection document/sticker available?

  • Is the swing radius of the crane barricaded?

  • Rigging equipment in compliance?

  • Are all other trades out of the area when craning operations are being performed? Area barricaded?

Electrical Safety (Subpart K - 1926.400)

  • Electrical Safety (Subpart K - 1926.400)
    https://www.ecfr.gov/cgi-bin/retrieveECFR?gp=1&SID=b82849dbe6eb55c8710eca668249ba2f&ty=HTML&h=L&mc=true&r=SECTION&n=se29.8.1926_1400

  • Are GFCI's being used on all temporary power and frequently tested?

  • Is temporary panel in compliance? No openings?

  • Are all extension cords in compliance and not exposed to sharp edges and vehicle traffic?

  • Are all temporary lights fully caged to prevent accidental breakage and are they secured properly?

Fall Protection (Subpart M - 1926.500)

  • Fall Protection (Subpart M - 1926.500)
    https://www.ecfr.gov/cgi-bin/retrieveECFR?gp=1&SID=b82849dbe6eb55c8710eca668249ba2f&ty=HTML&h=L&mc=true&r=SECTION&n=se29.8.1926_1500

  • Is there a documented fall protection plan in place for roofing activities and is it being followed?

  • Are all employees exposed to fall hazards of 6' or more protected with fall protection?

  • Are all floor holes 2" or larger covered, labeled and secured?

  • Are employees who are wearing PFAS properly trained in how it works?

  • When guardrails are used for fall protection are they at the right height and capable of withstanding a force of at least 200 pounds?

Fire Extinguishers (Subpart F - 1926.150)

  • Fire Extinguishers (Subpart F - 1926.150)
    https://www.ecfr.gov/cgi-bin/retrieveECFR?gp=1&SID=b82849dbe6eb55c8710eca668249ba2f&ty=HTML&h=L&mc=true&r=SECTION&n=se29.8.1926_1150

  • Are fire extinguishers on site and are they being inspected monthly?

  • Do we have a fire extinguisher for every 3000 square feet of the protected building and located not more than 100 feet from each other?

  • Are fire extinguishers placed by egress/EXIT doors?

Flammable and compressed gas cylinders (Subpart F - 1926.152)

  • Flammable and compressed gas cylinders (Subpart F - 1926.152)
    https://www.ecfr.gov/cgi-bin/retrieveECFR?gp=1&SID=b82849dbe6eb55c8710eca668249ba2f&ty=HTML&h=L&mc=true&r=SECTION&n=se29.8.1926_1152

  • Are approved flammable containers labeled as to contents?

  • Are compressed gas cylinders capped and secured in an upright position?

  • Are LP tanks stored outside when not in use?

HAZCOM - Right to Know (Subpart D - 1926.50)

  • HAZCOM - Right to Know (Subpart D - 1926.50)
    https://www.ecfr.gov/cgi-bin/retrieveECFR?gp=1&SID=b82849dbe6eb55c8710eca668249ba2f&ty=HTML&h=L&mc=true&r=SECTION&n=se29.8.1926_150

  • Are safety data sheets (SDS) readily available for hazardous chemicals?

Housekeeping (Subpart C - 1926.25)

  • Housekeeping (Subpart C - 1926.25)
    https://www.ecfr.gov/cgi-bin/retrieveECFR?gp=1&SID=50f936778209187a16b413214e3e2095&ty=HTML&h=L&mc=true&r=SECTION&n=se29.8.1926_125

  • Housekeeping being conducted and aisles free of debris?

Ladders (Subpart X - 1926.1053)

  • Ladders (Subpart X - 1926.1053)
    https://www.ecfr.gov/cgi-bin/retrieveECFR?gp=1&SID=50f936778209187a16b413214e3e2095&ty=HTML&h=L&mc=true&r=SECTION&n=se29.8.1926_11053

  • Are step ladders in good condition and being used for their designed purpose? Opened up and not leaning against a wall?

  • Are extension ladders in good condition and if used for access, do they extend at least 3' and are they secured?

Machine Guarding (Subpart I - 1926.300)

  • Machine Guarding (Subpart I - 1926.300)
    https://www.ecfr.gov/cgi-bin/retrieveECFR?gp=1&SID=50f936778209187a16b413214e3e2095&ty=HTML&h=L&mc=true&r=SECTION&n=se29.8.1926_1300

  • Are machine guards in place on all rotating/reciprocal tools and equipment?

  • Are all hand tools free from visible defects and in good condition?

Motor Vehicles & Equipment (Subpart O - 1926.600)

  • Motor Vehicles & Equipment (Subpart O - 1926.600)
    https://www.ecfr.gov/cgi-bin/retrieveECFR?gp=1&SID=50f936778209187a16b413214e3e2095&ty=HTML&h=L&mc=true&r=SECTION&n=se29.8.1926_1600

  • Are all employees exposed to or working adjacent to moving motor vehicles wearing at least a class 2 high visibility garment?

  • Are daily inspections being conducted on ALL motorized equipment and are operators trained and authorized by their employer?

  • If an aerial lift basket is used on a construction forklift, is it the right size (does not exceed more than 10" of the wheelbase), secured and fall protection provided?

  • Is the equipment current with annual inspection?

  • Are chains across gate in scissor lifts?

  • Seatbelt being worn?

  • Is audible alarm working?

PPE (Subpart E - 1926.95)

  • PPE (Subpart E - 1926.95)
    https://www.ecfr.gov/cgi-bin/retrieveECFR?gp=1&SID=50f936778209187a16b413214e3e2095&ty=HTML&h=L&mc=true&r=SECTION&n=se29.8.1926_195

  • Is PPE being worn and in compliance with site and OSHA requirements?

Scaffolding (Subpart L - 1926.450)

  • Scaffolding (Subpart L - 1926.450)
    https://www.ecfr.gov/cgi-bin/retrieveECFR?gp=1&SID=50f936778209187a16b413214e3e2095&ty=HTML&h=L&mc=true&r=SECTION&n=se29.8.1926_1450

  • Has the scaffold been erected/dismantled by a competent person?

  • Have all the employees working on the scaffold had user training? Are they aware of the hazards?

  • Is the scaffold bearing on baseplates and mudsills and is it level?

  • Are ALL of the open sides and ends of the scaffold barricaded for fall protection?

  • As a best practice, is the scaffold tagged "ready for use" or "not ready for use"?

Silica (Subpart Z - 1926.1153)

  • Silica (Subpart Z - 1926.1153)
    https://www.ecfr.gov/cgi-bin/retrieveECFR?gp=1&SID=50f936778209187a16b413214e3e2095&ty=HTML&h=L&mc=true&r=SECTION&n=se29.8.1926_11153

  • Has exposure to silica been controlled and monitored?

Stairways (Subpart X - 1926.1050)

  • Stairways (Subpart X - 1926.1050)
    https://www.ecfr.gov/cgi-bin/retrieveECFR?gp=1&SID=50f936778209187a16b413214e3e2095&ty=HTML&h=L&mc=true&r=SECTION&n=se29.8.1926_11050

  • Is there a handrail or stair rail along each unprotected side or edge?

  • Are stairs with 4 or more risers or rising more than 30" equipped with a handrail or stair rail?

  • Is the temporary handrail at least 3"from the wall?

  • At points of access higher than 19", is a step, walkway or ramp being used?

Steel Erection (Subpart R - 1926.750)

  • Steel Erection (Subpart R - 1926.750)
    https://www.ecfr.gov/cgi-bin/retrieveECFR?gp=1&SID=50f936778209187a16b413214e3e2095&ty=HTML&h=L&mc=true&r=SECTION&n=se29.8.1926_1750

  • Has a site specific steel erection plan been developed and being followed?

  • Has a site specific SEQUENCING plan been developed and is it being followed?

  • Are all other trades out of the area and is the area barricaded while performing steel erection?

  • Has a fall protection plan been developed and discussed with erection crew?

Trenching/Excavating (Subpart P - 1926.650)

  • Trenching/Excavating (Subpart P - 1926.650)
    https://www.ecfr.gov/cgi-bin/retrieveECFR?gp=1&SID=50f936778209187a16b413214e3e2095&ty=HTML&h=L&mc=true&r=SECTION&n=se29.8.1926_1650

  • Is there a competent person on site while performing trenching/excavating?

  • Is there adequate cav-in protection for employees working in trenches/excavations greater than 5' in depth?

  • Is there an access/egress ladder in the trench/excavation (4' or deeper) and is it within 25' of the workers?

  • Are the spoil piles back at least 2' from the face of the excavation?

  • Are all audible alarms in operation on earthmoving equipment and loud enough to hear?

Misc. site photos

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.