Title Page
-
Jobsite
-
Location
-
Conducted on
-
Prepared by
-
Completed on
AMS Safety Program Administration
-
Weekly Toolbox Talks
-
First Aid Kits onsite
-
Task Hazard Analysis completed for each task / crew
Housekeeping
-
Work area clean and orderly
-
Adequate lighting
-
Cords and leads properly routed
-
Work area clear of slips, trips and fall hazards
-
Stairways / walkways clear
-
Trash picked up
-
Break area / trailer orderly
Working at Heights
-
Fall risk of 6 feet or more? (Including voids, pits and trenches).
-
Guard rails in place where required
-
Wall or roof openings covered or barricaded
-
Floor openings covered or barricaded
-
Fall protection used when needed
Equipment
-
Unsafe or damaged equipment / tool? (Including missing or damaged guards).
-
Daily inspections of fork trucks, AWP, lulls, ECT
-
Harness and lanyards used in AWP
Hot Work, Welding, Cutting
-
Hot work permits in order
-
Flash back arrestors installed on torch
-
Fire extinguisher on site - inspected
-
Fire watch monitoring the area
-
Weld screens in use
-
Compressed gas cylinders properly stored
Scaffolding
-
Has scaffolding been erected correctly under the supervision of a competent person?
Cranes
-
Proper set up including distance to overhead power lines (20 ft)
-
Ground conditions verified (sewers, valts)
-
Lift plan required
-
Swing radius protected / barricated
Lifting Equipment
-
Rigging properly inspected
-
Unsafe or damaged lifting equipment, including ropes, slings, chains, hooks
-
Riggers certified and qualified
Fall Arrest Equipment
-
Proper lanyards used
-
Unsafe or uncertified anchor points
Ladders
-
Extension ladders set up with 4:1 ratio
-
Side rails extend 36 inches above landing
-
Step ladders fully open when in use
-
Ladder suitable for job? (E.g. Metal ladder used for electrical work / incorrect ladder for job).
Excavation
-
Competent person on site
-
Underground utilities marked
-
Adequate benching, shoring, sloping and or proper trench box
-
Access and egress means provided (not to exceed 25 feet)
Confined Space
-
Proper permits filled out
-
Permit posted at entry
-
Energy source locked out
-
Adequate ventilation
Personal Protective Equipment (PPE)
-
ANSI approved safety toe leather boots
-
Hard hats worn
-
Gloves being worn and adequate for the work activity
-
Face shields being used with safety glasses when required
-
Welding hoods being worn in conjunction with safety glasses
-
Eye protection being worn and adequate for the work activity
-
Hearing protection
-
Respirators and masks utilized when needed (welding, silica, chemicals)
-
High visible clothing in use when needed
-
Personal monitors required / worn properly (CO-O2-H2S)
Work Environment
-
Lack of / or inadequate amenities (toilets, wash area, lunch rooms, etc.)
-
Insufficient lighting
-
Inadequate housekeeping
Electrical Hazards
-
Unsafe electrical cords (damaged, missing ground prong inspected)
-
Overloading outlets
-
Lack of Lockout / Tagout (LOTO) procedures for electrical equipment
-
GFCI protection utilized
-
Electrical panels labeled and covered
Corrective Actions
-
Enter any corrective actions that will be undertaken
Sign Off
-
Onsite Representative
-
Auditor
-
GC, CM, Site Rep