Information
Asset Information
-
Audit Title
-
Asset No:
-
Door Location
-
Conducted on
-
Prepared By:
-
Site:
Asset Information
Asset Information
-
Make
- Besam
- KABA
- Dorma
- GEZE
- JMD
- Stanley
- Tormax
- FAAC
- Came
- Ditec
- sesamo
- Other
-
Model
-
Door photos
-
Door Type
-
Door Style
- Swing
- Bi-Part Slide
- Single Slide
- Bi-Fold
- Single Telescopic
- Double Telescopic
- Other
-
Arm Type installed?
-
If OTHER then detail
-
Door Construction
-
If OTHER then detail
-
Hinge Type
-
If OTHER then detail
-
Electronic lock system installed?
-
-
If OTHER then detail
-
Entry Devices Installed?
- Button
- Sensor
- Access Control
- Other
-
If OTHER then detail
-
Exit Devices Installed?
- Button
- Sensor
- Access Control
- Other
-
If OTHER then detail
-
Keys Switch installed?
-
Is key available
-
If OTHER then detail
-
Maintenance Label Installed?
-
Is CE label installed
PMI Door Checks
General Condition
-
Door Condition?
-
Operator Condition?
-
Mechanical Function & Operation?
-
Smoothness of Operation?
-
Cables connection and loops condition?
-
KeySwitch Operation
-
Visual Drive belt & tension check
-
Visual Track Check
Entry Devices
-
Entry Button(s)
-
Entry Sensor(s)
-
Does Entry Sensor meet 1400mm test
-
Entry Mat
-
Entry Type Other
Other Entry Type
-
Exit Devices
-
Exit Button(s)
-
Exit Sensor(s)
-
Does Exit Sensor meet 1400mm test
-
Exit Mat
-
Exit Type Other
Other Exit Type
-
Power
Mains Power
-
Are spurs labelled.
-
Is spur(s) in easily accessible location within 2m of door
-
Electrical fused outlet should be positioned so that users may switch off the doors in the event of emergency or other circumstances. We would advise spur(s) may need relocation.
-
Power Down Test carried out
-
Power down test result
-
Reason
Batteries
-
Is battery support installed?
-
Battery Condition?
-
Battery Require Replacement?
-
Add media
Fire Alarm
-
Fire alarm relays installed
-
It is not clear to us whether a fire interface has been installed for this door, therefore if is door requires fire alarm interface Client is advised to check this with their appointed fire advisor, and check during regular fire alarm test as to whether this door does respond in a suitable way. Fire alarm interfacing and programming can be retrospectively carried out. Further information available on request.
-
Has it been tested
-
CLIENT IS ADVISED TO CHECK DOOR FUNCTION DURING WEEKLY
FIRE ALARM TEST OR AT EARLIEST OPPORTUNITY.
Safety Devices
Safety Devices Fitted
-
Door Type?
- Swing
- Bi-Part Slide
- Single Slide
- Bi-Fold
- Single Telescopic
- Double Telescopic
- Other
-
Side screen safety sensors installed?
-
Pockets screens installed?
-
1200mm barrier installed across opening section?
-
Hold Open Safety Beams Installed?
-
Are they installed between 300 & 600mm from floor level?
-
These are incorrectly installed and will require remedial works
-
Are safety devices adequate and compliant?
-
Is system operating as "Low Energy"?
-
As door are operating as "Low Energy" some safety devices are not required. It is considered that the door will present a risk on impact as impact level will be so low.
-
Opening side safety sensor fitted?
-
Closing side safety sensor fitted?
-
Do safety sensors work?
-
Do safety sensors meet standard?
Safety Device Checks
-
Inside Presence Safety Sensor Box Test
-
Outer Presence Safety Sensor Box Test
-
Side Screen Presence Safety Sensor Box Test
-
Door Stop/Reverse Test (low energy only)
Other Safety Devices
-
Finger protection installed?
-
Safety Railing(s) installed?
-
Are they installed correctly (gaps <50mm to frame)?
-
Are they filled in with glass or solid
-
Warning Signs installed?
Trap Points
-
Have any Trap Points been identified?
Trap Point
-
Hazard Type
-
Summary PMI Outcome
Additional Recommendations
-
Additional Recommendations
PMI Outcome
-
Based on the above assessment we consider this door system to have:
-
Congratulations your system has PASSED its basic visual PMI checks, and is considered at his time to be safe to operate.
Please ensure though you carry our regular visual checks and ensure any actions needed are reported immediately to us. -
Your system is considered to have passed the basics visual checks, however we have identified additional further actions that are required to make the doors function fully or to meet the BS7036 standard to which they should have been installed. Additional remedial works will be provided to you in a separate report along with associated costs.
-
Your system is considered to have FAILED it's visual PMI checks on a number of serious items and in our opinion is unlikely to comply with BS7036 until these remedial actions are taken to ensure the door system is safe for use. The remedial actions will be provided to you in a separate report along with associated costs.
In the meantime you may wish to consider placing the door "out of action"until these remedial works are completed! -
Your system has been CONDEMNED which indicates that we have found significant failures in either the door structure which could lead to injury, or failures in system operation that render the door unsafe for continued use.
We strongly advise the door be placed "out of action" until such time as remedial or replacement works can be carried out.
-
Engineer signature