Information
-
Asphalt Plant Audit
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
Control House - Scale
-
T5 - Risk Assessment Manual being done daily and correct?
-
Check T5 Manual
-
Emergency Phone Numbers Posted?
-
Smoke Detectors working properly?
-
First Aid Kits Stocked?
-
Stairs and handrails in good working condtion?
-
MSDS manual up to date?
-
Check one product and make sure its up to date in manual.
-
Radio communication with loader and ground employees?
-
Monthly Fire extinguishers inspection log done/or tags logged?
-
Housekeeping Good?
-
Plant horn works for start ups?
-
Pedestrian plan in place, map posted where it can be scene by customers?
-
Windows clear, no obstructions to silos or loadout?
-
No fire hazardous, such as bad extension cords, trash can overfilled, flammable materials not stored properly?
Personal Protective Equipment
-
Hard Hats, safety glasses, steel toe boots and hearing protection being worn?
-
Proper gloves being worn when handling materials?
-
If respirators are used (other than dust masks worn on a voluntary basis) employees are medically qualified, trained and fit tested for respirator use?
Lockout / Tagout
-
Lockout / Tagout manual up to date and being used properly?<br>
-
Valve covers and lockout equipment devices available?
-
Each employee has his own lock?
-
Arch Flash equipment in good condition. Gloves, hardhat with face shield, Coveralls or uniforms.
-
Are all electrical panels,breakers and disconnect boxes labeled properly with arch flash lables?
-
Check lockout/tagout manual
Electrical Hazards
-
Is electrical wiring free of damage and fraying?
-
Are permanet splices in cables insulated to the equivalent of the oringinal, strong, and sealed to moisture?
-
Are no repairs done to extension cords with the exeception of proper plug replacement?
-
Are GFCI provided on outlets around water and all extension cords?
-
3 foot clearance around electrical boxes?
-
All electrical switches, breakers, etc. labled and warning signs posted around all electrical installations?
Confined Space
-
Confine Space Manual in place and being used properly?
-
Confine Space Monitor being calibrated and logged? At least every two weeks?
-
Bump Test being performed before each entry and logged?
-
All confined space areas properly labeled?
-
Check Confined Space Manual
Fall Protection/Fall Hazards
-
All fall protection in good working condition?
-
Date of first use logged on fall protection devices (PPE) tag?
-
Ladders being inspected before each use?
-
Check ladders for damage.
-
If employees are working at heights, is the area below barricade off half the distance they are working?
-
All ramps bermed half the distance of the largest equipment being used on ramps?
-
Barricades used under silo drop gate?
Stairs and Walkways
-
All stairs and walkways in good working condition?
-
Proper height on all handrails, at least 42"
-
Swing Gates on all working platforms?
-
Toe Boards on all Walkways?
-
Are housekeeping practices carried out to insure work area are safe from trip/fall hazards to employees?
Guards
-
Are all belts and pulleys within 42 inches form the ground fully guarded?
-
Are all conveyor systems within 7 foot of walking/working surface equipped with a shut-off cable or guard?
Liquid AC Loading and Unloading
-
All PPE in good working condition?
-
Hose and Coupling in good working condition?
-
Wheels chocks in good working condition?
-
Unloading Sign in place?
-
Haulers wearing proper PPE and following APAC procedures?
-
Take Photo of Loading Area
Equipment
-
Daily equipment inspections being done daily?
-
Check one piece of equipment
-
Take picture of equipment and unit number
-
Are good house keeping practices employed in cab of equipment?
-
Seat and seat belt in good working condition?
-
Mirror adjusted properly and good working condition?
-
Back up alarm working proplery?
-
Check decibles 15' foot behind equipment - Above 90 dbs?
-
Access steps and railing in good working condtion?
-
Are parking brakes capable of holding mobile equipment with typical load on max grade?
Conveyance and storage of materials under pressure
-
All compressed gas cyclinders secured in safe manner and properly capped when not in use?
-
Are oxygen clyinders stored from flammable materials and at least 25 feet from flammable gas cylinders?
-
Annual inspsection done on all pressure vessels/compressors?
-
Are storage areas for cylinder bottles labled, Full and Empty?
-
Does all high pressure lines have the approved high pressure clamp? No raditor clamps?
-
Is compressed air used for cleaning purposes regulated to 30 pounds?
-
Add media
Lifting Operations
-
All lifting implements such as straps, cables and chains have their load limit identified, as applicable?
-
All safety latches in place?
-
Are employees lifting any material greater than 50 lbs?
Fire Protection
-
Are no smoking signs/labels posted around flammable materials?
-
Flammable Liquids stored an approved Safety Can and Containers?
-
Are all spills cleaned up?
Unsafe Behavior
-
All CRH FFE's being observed/safe behaivor observed during this audit? If no, please explain below, how it was corrected.
-
Other
-
Add signature