Information
-
Tesco Bank Replacement Site Survey
-
Conducted on
-
Surveyor:
-
Survey Type
- Replacement
- Relocation
- New Store
- Additional ATM
- Removal
- Other
-
Other Details:
-
Store:
-
Store Number:
-
Full Address
-
Postcode
-
Store Format
- Express
- Metro
- Extra
- Super Store
- One Stop
- Home Plus
- PFS
-
Location
-
Management Centre contact name
-
Phone:
-
Email (for RAMS to be sent)
Scope of Document
-
Criteria
The survey lays out the information required to be captured to enable a clean successful ATM Replacement installation to be performed without falter.
Expectation of Document
Surveyor to provide:-
- All sections to be completed in FULL.
- Digital Photographs to be recorded and embedded within survey doc.
- 1 CAD drawing supplied with the survey showing Plan and Elevation for Future State -
- All adaptations shown to achieve future state with new ATMs installed into
position showing all required service clearances achieved / items that are to be
moved / repositioned and infill panels shown.
- DDA no. 5 key height to be shown as per requirement for the particular ATM
type - with required plinth height shown to achieve it.
- Full quote included to show all additional works required to achieve positioning
and service clearances as necessary.
- Survey to be completed and returned within 5 working days of survey attendance day.
- Any additional works and materials over and above normal install work to be highlighted and additional cost quotes supplied with the survey.
2.0 ATM Internal Detail - CURRENT STATE
-
ATM Room Type and Construction
-
Does room meet Tesco Design Spec?
-
Is room clean and units currently serviceable?
-
ATM Models to be removed
-
ATM Model:
-
Serial Number:
-
Internal Position
-
ATM Models to be removed
-
ATM Model:
-
Serial Number:
-
Internal Position
-
ATM Models to be removed
-
ATM Model:
-
Serial Number:
-
Internal Position
-
ATM Models to be removed
-
ATM Model:
-
Serial Number:
-
Internal Position
-
ATM Models to be removed
-
ATM Model:
-
Serial Number:
-
Internal Position
-
Floor Construction & Floor Works required
-
Plinth (old) - identify plinth material and height
-
Material:
-
Existing ATM Through
-
Solid Wall Type/Thickness - is it thicker than 330mm?
-
No of skins?
-
Is there a basement that may affect the ATM removal, delivery, or installation?
-
ATM 1 - does ATM get power from a plug socket or hard wired?
-
Is the length of cable over 2.5 metres, or extension required?
-
ATM 2 - does ATM get power from a plug socket or hard wired?
-
Is the length of cable over 2.5 metres, or extension required?
-
ATM 3 - does ATM get power from a plug socket or hard wired?
-
Is the length of cable over 2.5 metres, or extension required?
-
ATM 4 - does ATM get power from a plug socket or hard wired?
-
Is the length of cable over 2.5 metres, or extension required?
-
If ATM is in Cash Office do we need to relocate any safes?
-
Staff Confirmation (name):
-
Staff Signature:
-
ATM 1 - external floor level to internal floor level variance - Use External floor as datum ie Ext floor lower / higher XXXmm - Show floor height variance AND planned plinth heights
-
ATM 2 - external floor level to internal floor level variance - Use External floor as datum ie Ext floor lower / higher XXXmm - Show floor height variance AND planned plinth heights
-
ATM 3 - external floor level to internal floor level variance - Use External floor as datum ie Ext floor lower / higher XXXmm - Show floor height variance AND planned plinth heights
-
ATM 4 - external floor level to internal floor level variance - Use External floor as datum ie Ext floor lower / higher XXXmm - Show floor height variance AND planned plinth heights
-
Door sizes material and lock types used?
-
Is a camera fitted to the ATM?
-
EFD Box installed inside safe?
-
Internal photo to be taken - condition of room
-
Internal photo to be taken - position of ATMs
-
Internal photo to be taken - Plinths
-
Internal photo to be taken - Alarms
-
Internal photo to be taken - Power / Comms Points etc
3.0 ATM Internal Detail - FUTURE STATE
-
6626 will be required unless service clearances met
-
DDA - ATM 1 - Planned external G/L to #5 key of new ATM
-
Does ATM achieve #5 key height (see appendix)
-
Show on Drawing section
-
DDA - ATM 2 - Planned external G/L to #5 key of new ATM
-
Does ATM achieve #5 key height (see appendix)
-
Show on Drawing section
-
DDA - ATM 3 - Planned external G/L to #5 key of new ATM
-
Does ATM achieve #5 key height (see appendix)
-
Show on Drawing section
-
DDA - ATM 4 - Planned external G/L to #5 key of new ATM
-
Does ATM achieve #5 key height (see appendix)
-
Show on Drawing section
-
Planned ATM location - are service clearances restricted?
-
Give dimensions for clearances by Gas / Electric, etc.
-
Plinth types to be used and positions
-
Bolt sizes if above 75mm
-
Gunnebo panels required front wall only - internal and external, give sizes for infills. Show SCAR Plate to be used front and back.
-
External Shutters to be removed/amended. An installed ATM requires at least 75mm space from building elevation to shutters.
-
Is there a requirement for relocation of existing items before works commence, ie shelving/cabling/files/cash safe/power/Comms/BT points/cameras, etc.
-
Show on CAD drawing of future state with position of planned ATM types & plinths Plan & Elevation. Include service clearances shown, dimensions for all include #5 key / plinth position, etc.
4.0 Delivery & Transport
-
Delivery resources required & Method Summary NB: If more than TWO operatives required please justify.
-
Detail any special requirements to enable delivery: Floor surface type - detail requirement for floor protection (barriers or boards, etc) segregation for public safety. Show delivery route.
Vehicle Access & Vehicle Parking
-
Any restrictions, time limits, etc.
-
Are any permissions or permits required?
-
Are there any public road restrictions?
-
Site Access restrictions to ATM internal or external?
-
Steps in to the ATM room?
-
Any temporary prep site works required to enable delivery: door frame removal, etc?
-
Noise Restrictions (residential etc)
-
Photos taken - Parking Area / Delivery Route / Restrictions etc
5.0 EXTERNAL Detail
-
CCTV Cameras facing planned ATM area - take photos
-
Exterior lighting in ATM area - is this adequate? Take photos.
-
Other actions required or comments:
-
Photos please ensure photos are taken externally
-
Existing ATMs
-
Existing ATM
-
Collars
-
Collars
-
Customer Signage
-
Customer Signage
-
Existing Lighting
-
Existing Lighting
-
Bollards
-
Bollards
-
CCTV
-
CCTV
-
Show on a drawing existing ATM external dimensions Plan and Elevation. If bollards installed already - show on drawing.
-
If bollards installed already, do these offer adequate protection?
-
If no, is it feasible to install bollards?
6.0 Making Good
-
Internally - What above standard finish is required in making good (Materials/Time/Cleaning Up/Filling) required during swap outs - if yes add detail/photos or drawing on separate sheet.
-
Externally - What above standard finish is required in making good (Materials/Time/Cleaning Up/Filling) required externally - if yes add detail/photos on separate sheet - include all relevant info, eg Paint type and colour, Brick Type, mortar coloured, Tile, etc. Add drawing / photo if required.
7.0 Survey Output Requirement
-
2x CAD drawings Plan and Elevation showing current state and future state to show: (all dimensions for service clearances)
- Height #5 key position
- Difference in Int/Ext floor height
- Plinth information & position
- Relocation of items (what they are and where they are to go)
- Future plan showing service clearances around the ATMs.
Photographs to be embedded within the document (all relevant photos should be added and include the following information.
-
ATM Room Condition
-
ATM Room Condition
-
Current position of ATMs and Plinths Internally
-
Current Position of ATMs and Plinths Internally
-
Current position of ATMs and Plinths Externally
-
Current Position of ATMs and Plinths Externally
-
Power supply sockets / alarms
-
Power supply sockets / alarms
-
CCTV Cameras / External Lighting / Customer Signage / Bollards
-
CCTV Cameras / External Lighting / Customer Signage / Bollards
-
Parking Area / ATM delivery route including restrictions steps / bollards etc
-
Parking Area / ATM delivery route including restrictions steps / bollards etc.
-
Are all sections completed?
-
To show all additional works required including specific materials such as matching replacement brick type, mortar colour, paint type, etc.
-
New install to meet minimum Service Clearance and DDI for the No 5 key as per attached documentation.
-
Survey to be completed and submitted to NCR within 5 working days of the survey completion.
-
Additional works & materials shown and cost quotes supplied
-
It is expected that ANY exceptions will be highlighted whether they are requested within this document or not that will affect the installation negatively.
Appendices
Clearance dimensions
-
ATM minimum service clearance requirements (looking at the ATM from the rear) - Dimensions from the edge of the main body of the ATM.
5887: 320mm (RH Side) / 152mm (LH Side) / 1000mm (Back)
6625: 380mm (RH Side) / 300mm (LH Side) / 890mm (Back)
5877: 110mm (RH Side) / 400mm (LH Side) / 1000mm (Back)
6626: 380mm (RH Side) / 300mm (LH Side) / 900mm (Back) -
DDA Rules Recommended Key #5 Heights
5887 = 900mm to key 5
5877 = 1028mm to key 5
6625 = 882mm to key 5
6626 = 965mm to key 5
6622 FA = 936mm -
ATM Aperture Sizes:
5887 - Measure from floor Ext (828mm high) aperture = 730mm (H) 640mm (W)
6625 - Measure from floor Ext (819mm high) aperture = 740mm (H) 640mm (W)
P77 - Measure from floor Int (576mm high) aperture = 1015mm (H) 516mm (W)
S26 - Measure from floor Int (711mm high) aperture = 793mm (H) 445mm (W)