Title Page

  • Conducted on

  • Prepared by

  • Location
  • City or Town

  • Structure #

  • Permit #

  • Electrical Meter #

  • Panel/Face Number(s)

  • Structure Type

  • Face Size

  • Take Picture Of Structure

General Condition

Walk Around Inspection

  • Obvious defects, i.e. is structure leaning?

  • Note any obvious hazards:

FOUNDATION-FOOTING INSPECTION

All Foundations: (Important! Must dig down to concrete if it is below ground level)

  • Structure Type

  • * Are there any obvious cracks in concrete?

  • * Are there any voids between concrete and Monopole

  • * Are there any voids where concrete meets ground?

  • * Are all nuts on anchor bolts and are they tight?

  • * Is there excessive rust on anchor bolts, plates, gussets or I-Beams? (Important! Using a hammer,<br>check the integrity of the steel on any areas showing rust, no matter how minor. Areas of<br>deterioration must be noted on this form and dealt with immediately)

  • * Are all welds around base plate in good shape?

  • * Are all welds around gusset plates in good shape?

  • * Is grout under the base plate(s) in good condition?

  • Comments

COLUMN SPLICES (Monopole and I-Beam)

  • Structure Type

Transitions:

  • Are There Telescoping transitions?

  • * Fillet weld to upper pipe

  • * Fillet weld to lower pipe

  • * Plug welds

  • * Gusset welds

Butt splices on column/I-Beam:

  • Are There Butt Splices?

  • * Check all welds around column/I-Beam for obvious cracks

  • * Any voids in welds

  • * Any material failure

  • * Any shimming in weld area with foreign objects

  • * How is overall quality of the welds?

  • * How is condition overall?

  • Comments:

PLATE TO PLATE BOLTED SPLICES (Monopole and I-Beam)

  • Structure Type

  • Are There Plate To Plate Bolted Splices?

  • * Are there any deformations in the plates?

  • * Are the bolts tight?

  • * Are any bolts missing?

  • * Are bolts in need of replacement?

  • * Are gussets in good condition?

  • * Are all welds in good condition?

  • * Are there any cracks in any welds?

  • Comments:

HEAD PLATE TO COLUMN PLATE CONNECTION (Monopole)

  • Structure Type

Welds:

  • * Column plate to pipe

  • * Gusset plates to pipe

  • * Gusset plates to column plate

  • * Torsion pipe to riggers

  • * Is there any visible space between column plate to head plate?

  • * Are there any nuts or bolts missing?

  • * Are all connecting nuts and bolts tight?

  • * Is there excessive rust on nuts and bolts?

  • * Is there any visible shimming of foreign material between plates?

  • * Is there excessive visible rust between plates?

  • * How is overall condition?

  • Comments

CONNECTIONS AT TORSION PIPE (Monopole)

  • Structure Type

  • Welds at beam to pipe connection above head plate

  • Welds at outrigger connections to pipe

  • Condition of pipe

  • * Is pipe dimpled anywhere?

  • * Is pipe torn anywhere?

  • Comments:

UPRIGHT TO OUTRIGGER (Monopole, I-Beam, Wood Pole)

  • Structure Type

Materials:

  • * Is there any deformation of clips to uprights?

  • * Is there any deformation of gussets to uprights?

  • *Is there any twisting or deformation of uprights?

Condition of welds:

  • * Clips to uprights

  • * Clips to outrigger

  • * Clips to stringers

  • * How is overall condition?

  • Comments:

BOLTS AND WELDS

  • Structure Type

Angle Iron:

  • * Check all welds around angle for obvious cracks

  • * Any voids in welds

  • * Any material failure

  • * Any shimming in weld area with foreign objects

  • * Are there any nuts or bolts missing?

  • * Are all connecting nuts and bolts tight?

  • * Is there excessive rust on nuts and bolts?

  • * How is overall quality of the welds?

Materials:

  • * Is there any deformation of clips to uprights?

  • * Is there any deformation of gussets to uprights?

  • * Is there any twisting of deformation of uprights?

Condition Of Welds:

  • *Clips to uprights

  • *Clips to outriggers

  • * Clips to stringers

  • * How is overall condition?

ACCESS LADDERS (Monopole, I-Beam, Wood Pole)

  • Are The Fixed Access Ladders?

Materials:

  • * Are there an ladder rungs missing?

  • * Are any ladder rungs bent?

  • * Are all bolted connections secured?

  • * Welds on tabs from ladder to structure

  • * How is overall condition?

  • *Are the ladder safety cables installed properly and in good condition

  • Comments:

CATWALK - PLATFORMS (Monopole, I-Beam, Wood Pole)

  • Are There Catwalks Installed?

  • * Connections - catwalk to walk arms

  • * Connections - catwalk to walk around catwalk

  • * Condition of steel grating

  • * Are safety cables-life lines in good condition?

  • * Are safety cables secured correctly on all catwalks?

  • * How is overall condition?

  • Comments:

GENERAL INFORMATION (Monopole, I-Beam, Wood Pole, A-Frame)

  • Is There An Electric Service

  • * The condition of the light fixtures

  • * The condition of electrical service

  • * Are all lights working?

  • * Is the time clock set to the correct time?

  • * Are there any power line problems?

  • * Does the structure need painting?

  • * Is the Adams logo fastened correctly (centered on skirt)

  • How is overall condition of Skirt/apron?

ADDITIONAL COMMENTS And Signature

  • Note any areas of importance or concern

  • Additional Photos

  • Signature of Inspector

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.