Title Page
-
Conducted on
-
Prepared by
-
GPS Location
-
Panel/Face Number
-
Structure Type
-
Face Size
- 14x48
- Poster
- 12x24
- 10'6"x36'
- 10x30
- 12x48
- Other
-
Take Picture Of Structure
Structure Condition
-
Inspect the base ground for damage or corrosion. Repair or clean the ground attachments as needed.
-
Inspect access ladders, catwalks and safety line for any visible damage.
-
Inspect trim system for any damage.
-
Is the Adams logo fastened correctly (centered on skirt)
-
How is overall condition of Skirt/apron?
PM Checklist
-
Manufacturer
-
Enter digital face manufacturer name
-
Contact manufacturer service center to inform you are onsite
-
Photograph The Display for attachment to the ticket ID
-
Look at the display face for any visual issues. (repair/replace as needed when on structure)
-
Verify white balance visually. Report any variances to the NOC for remote adjustments.
-
Calibrate any single modules as needed after making any adjustments to the entire face color balance.
Control System
-
Inspect the componenets of the control system for any visible corrosion. Apply electrical grease as needed to all ethernet points.
-
Clean and inspect control box filters.
-
Test the control fan system by turning down the temp selector on the control unit.
-
Inspect wireless antenna mounts and connectors for damage or corrosion. Clean as needed with electrical grease.
-
Inspect photocell for damage and operation. Cover the unit and verify dimming of the display.
-
Test redundant PC operation by disconnecting both ethernet cables to the primary PC. Verify control transfer to redundant PC.
-
If accessible, clean the camera housing lens and verify any adjustments that may be needed.
-
Check for any unsecured control lines external to the sign.
Digital Face
-
Replace or clean Filter material in all cabinets
-
Explain issue or upload photo
-
Inspect all cabinets for signs of corrosion or water.
-
Explain issue or upload photo
-
Inspect operation of all power supply fans while in cabinet, Replace power supplies with failed fans.
-
Explain issue or upload photo
-
Visually inspect AC connections on power supplies for secure fit.
-
Verify closure of all door latches upon completion of each cabinet. Re-verify all doors are closed prior to exiting the structure.
-
Inspect control cards, (Formetco) MLC (Daktronics) eFlares (watchfire) for signs of corrosion. Apply dielectric grease as needed.
Spare Parts Box
-
Inspect spare parts enclosure for any signs of water intrusion.
-
Explain issue or upload photo
Parts count
-
How many mods?
-
How many power supplies?
-
How many ribbon cables?
-
How many control cards/MLCs/Eflares?
-
List any other parts on hand.
Additional Comments And Signature
-
Note any areas of importance or concern
-
Additional Photos
-
Signature of Inspector