HEALTH

  • Sensor Tap working and heating up

  • Hot water available to all sinks

  • Paper towel holder installed

  • Soap Dispenser installed

  • Fridges and Freezer set to Temp

POS COUNTER (INTERNAL)

  • - POS Counter cupboard doors - built as per Standard Drawings

  • - POS Counter cupboard doors - perorated metal inserts for ventilation - as per Standard Details

  • - POS Counter cupboard doors - Handles installed correctly and all locks working on all doors

  • - Corian benchtop built to specifications and silicone installed where required, Cables holes installed etc

  • - Correct shelving in POS cupboards

  • - Safe Bolted down (Concrete Plinth)

  • - Display Fridge - Positioned correctly and Set at correct Temperature

MENU PYLONS

  • - Menu pylons correct height (2400mm or 2600mm) with correct framework above

  • - Menu Pylon - (Next to POS Counter) - as per Standard Details.

  • - Menu Pylon - Boost signage as per Standard Drawings

  • - Menu Pylon - Digital Screens installed and commissioned

  • - Menu Pylon Secondary - (Behind the POS Counter) as per Standard Drawings

  • - Menu Pylon Secondary - Boost Signage as per Standard Drawings

  • - Menu Pylon Secondary - Digital Screens Installed and commissioned

POUR-UP COUNTER (INTERNAL)

  • - Bench Top - As Per Spec<br>- Ensure smooth finish and no sharp edges

  • Blender Cut outs and cables holes - as per specifications

  • GPO's are accessible below

  • - Cupboard Vented Doors including handles & locks - as per Standard Drawings

  • - Cup Dispensers (Gaskets installed) - As per Spec

  • - Dark Blue powder coated shroud - as per standard detail. Straw and napkin dispensers fit correctly

  • Silicone installed as required - neat and tidy

JUICE DISPENSER STATION (MAKER 1)

  • - Banana Bin - Drawers Finished as per Standard Drawings

  • - Drawer Runners are heavy duty and fitted correctly

  • - Under Counter Bin - Doors finished as per Standard Drawings

  • - Under Counter Cupboards - Hung level fitted with handles to Standard Drawings

  • - Juice Dispenser Bench - Stainless Steel Counter Top as per specs

  • - Printer Shelf - as per Standard Drawings

  • - Silicone where Required - As Per Spec

MAKER 2 STATION

  • Ice well built as per Standard Details with folded Stainless Steel where required

  • Ice well plumbed to tundish - drainage tested. Tundish waste point sealed at base <br>

  • Ice well lid - has no sharp edges

  • Lids Tray - No sharp edges, drop in grate provided with no sharp edges

  • Lids Tray - connected to tundish via pipe behind splashback - drainage tested

  • Supplement Shelf - Fixed to Wall (Stainless Steel Screws Used)

  • Frameless Sneeze Guard - as per spec

  • Chest Freezer - Installed / Working at Temp / Clean

PREP AREA / JUICER BENCH

  • - Stainless Steel Bench - As Per Spec

  • - Fruit Drawers - In Position & Set to Correct Temperature<br>- Note Temperature

  • - Silicone where Required - As Per Spec

  • - Cupboards / Doors Hung Straight with Handles- As Per Spec

  • - Ice Machine - In Position and Operating

  • - Internal Wall - As Per Spec

WASH-UP STATION

  • - Fill all sinks<br>- Empty all sinks at the same time to ensure draining of water

  • - Wash Up Sinks - Prep/Wash Up/Hand Wash Basin - As Per Spec

  • - Internal cupboards is completed in Stainless Stell

  • - Cleaners Sink - Bench as per Standard Drawings

  • - Doors Stainless Steel hung evenly - As Per Spec including handles in correct position

  • - Tapware - As Per Spec

  • - All Plumbing & Waste Points sealed - No Leaks

  • - In Correct Position<br>- Hot Water running to all taps - Tested and Timed <br>- Check Pressure

  • - Stainless Steel Dry Rack (Fixed with S/S Screws) - As Per Spec

  • - Stainless Backing Wall - As Per Spec

  • - All Sinks are siliconed where required - As Per Spec

FLOORING

  • - Vinyl Flooring OR floor tiles - As Per Specification<br>

  • - Vinyl Joins Heat Welds Completed to standard / Epoxy grouting to tiles finished to standard

  • - COVING - Vinyl / Tiled or aluminium coving finished to company Standards to specified height

  • - Floor Waste / Bucket Trap finished as per spec

ELECTRICAL

  • - All GPO's are in correct positions as per electrical drawings

  • - Waterproof power points provided as required - as per Electrical drawings

  • - Waterproof power points provided as required - as per Electrical drawings

  • - EDB in correct location

  • - EDB - all circuits are labelled correctly

  • - All Data Points in correct location

  • - Stereo - Test speakers using audio cables provided

  • POS & Five Faces Wiring neat

INTERNAL PARTITION WALLS

  • Tiling - Yellow / Green tiled walls - as per spec

  • Blue ply walls internal - finished as per spec

  • Capping - Stainless or powdercoated capping finished to spec

  • Signage Plague - "2 Sip Guarantee" - installed in correct location with correct pins

KIOSK EXTERNALS

  • POS Counter: Merch Boxes - as per spec. Acrylic dividers provided. Ticket strips provided.

  • Pour Up Counter: As per Standard Drawings<br> - Blue tile finish as per spec with tile trims installed<br> - Dark blue powder coated shroud with napkin and straw cut outs

  • Green Ply "Hook-up wall" : Cladding - green printed ply board finish as per spec. Ply has had varnish applied and surface is smooth - not rough. Orange powdercoated strip has been installed.

  • External Walls: Blue Ply Sections - ply has had varnish applied and surface is smooth, not rough

  • External Walls - Contoured two-pack panelling. Installed as per spec. Two-pack smooth / no scratches or chips

  • External Walls - Tiled sections (Yellow and green) - tiles installed to spec. Smooth and straight lines. Grout installed correctly. no gaps

  • - Blue Ply kickers - set back, as per spec. No gaps. Siliconed at mall tile

  • Fruit Bowl & Frame as per Standard Drawings

  • Acrylic Insert provided for fruit bowl

GLAZING

  • Clear glazing above Hook-Up wall - Installed as per spec. Black glazing channel installed. Glazing sturdy

  • Silicone installed - neat and tidy

  • Framed, ribbed glazing - installed as per spec

  • Silicone installed to ribbed glazing

LIGHTBOXES, SIGNAGE & GRAPHICS

  • POS Counter Lightbox - as per spec - operating correctly

  • POS Counter graphic image - correct image, free of any printing flaws

  • Juice Dispenser Lightbox - Installed as per specifications, operating correctly

  • Juice Dispenser graphic image - correct image, free of printing flaws

  • Framed Lightbox - Installed as per specifications, operating correctly

  • Framed Lightbox graphic image - correct image, free of printing flaws

  • Framed "PICK UP" sign - installed in correct location - as per spec

  • Pour Up Counter: Acrylic Letters - as per Standard Drawings. Confirm correct 3M adhesive has been used. NO double sided tape

  • Green Ply "Hook-up wall": Yellow "Love Life" acrylic lettering fixed correctly. 3M adhesive glue has been used. NO double sided tape

METAL / STEEL WORKS

  • - Overhead Frame Structure as per Specs

  • - Entry Barn Single Door - Finished as per Standard Drawings

  • - Entry Barn Doors - Hung evenly & supported where hinges are installed<br>

STOREROOM

  • - Freezer Walkin - As Per Spec

  • - Is the temperature set to code<br>- Has the coolroom been cleaned<br>- Has the coolroom been sealed correctly<br>

  • - Tundish located in the correct position

  • Storeroom Shelving - Supplied and Installed

  • - Power points in nominated positions

  • - Storeroom floor has been sealed

  • Storeroom Split System A/C installed if specified

MISCELLANEOUS

  • - Fire Extinguisher - Supplied and Installed

  • - Fire Extinguisher - In Date

  • - Cleaning - has the store been professionally cleaned

  • - Spare tiles & touch up paint left for Partner

  • - Receipts for Tapware from Plumber for Warranty

STORE DETAILS

  • Store address
  • Select date

  • Add signature

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.