Page 1: Initial questions
-
Conducted on
-
Prepared by
-
Location
-
PN
-
Chamber Size
-
Sub-Contractor Gang
Page 2: Main checklist
-
Have sufficient rings been fitted to allow correct depth of cover
-
Has 100mm of compacted Type 1 been installed in base of excavation
-
has a sump been installed in FW4, FW6, CW1 & CW2
-
Has 50mm of dry mix concrete or C40 concrete been installed for chamber floor - FW Chamber Only
-
Are ducts cut flush with chamber wall
-
Are duct entries a minimum 75mm from the corner
-
Are Duct entries a minimum 150mm from base
-
Have brackets and bearers been fitted
-
Have surround to FW chamber been backfilled with compacted Type 1 or lean mix concrete (C40)
-
Has the FW frame & cover been bedded on 15mm - 40mm rapid set mortar
-
Has a concrete (C25/C30) surround been installed around the frame & cover to a width of 100mm - Verge Only
-
Is the frame & cover flush with the existing surface
-
Is reinstatement in accordance with SROH