Notification and Summary Data
-
No. Of Cooling Towers
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
-
Manufacturer
-
Period of Operation
-
Age
-
No. Of Closed Circuit Cooling Towers
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
-
Manufacturer
-
Period of Operation
-
Age
Water Treatment Programme Summary
-
Inhibitor
-
Product Name
-
Active Component
-
Bunded Storage
-
Auto Dosing
-
How is Dosing Controlled
Questions
-
Is the Cofely Legionella/Water Hygiene Scope Detailed in the Contract
-
Condition
-
Comments - Further Action Required
-
Do Cofely have a planner for Water Treatment tasks identifying who is responsible for which task?
-
Condition
-
Comments - Further Action Required
-
If Cofely place the order with the Contractor, Then is that Contractor a Preferred Supplier?
-
Condition
-
Comments - Further Action Required
-
Is the Scope that Cofely delegate to Sub Contractors Detailed?
-
Condition
-
Comments - Further Action Required
-
Has the Contractor provided a detailed break down of their Scope and Associated Costs?
-
Condition
-
Comments - Further Action Required
-
Do Cofely track the work of the Contractors against their Scope?
-
Condition
-
Comments - Further Action Required
-
Has Risk Assessments been completed for the prevention and control of Legionella Bacteria?
-
Condition
-
Comments - Further Action Required
-
Did the Assessment consider wether the risk could be prevented (I.e. eliminated)?
-
Condition
-
Comments - Further Action Required
-
Did the Person carrying out the Assessment have access to competent help and advice when carrying out the Assessment?
-
Condition
-
Comments - Further Action Required
-
If there are more than five employees in the organisation, are there significant findings of the Assessment recorded?
-
Condition
-
Comments - Further Action Required
-
Were Employees consulted about the Assessment and the Control Measures?
-
Condition
-
Comments - Further Action Required
-
Does the Assessment identify the circumstances which would require a review?
-
Condition
-
Comments - Further Action Required
-
Has a "Responsible Person" been identified in writing?
-
Condition
-
Comments - Further Action Required
-
Is there a nominated Deputy?
-
Condition
-
Comments - Further Action Required
-
Are Contact Details for these people readily available (in the event of an emergency)?
-
Condition
-
Comments - Further Action Required
-
Are the Roles and Responsibilities of all staff involved in the control regime clearly defined in writing?
-
Condition
-
Comments - Further Action Required
-
Have all Cofely staff received appropriate training?
-
Condition
-
Comments - Further Action Required
-
Are the roles and responsibilities of external contractors clearly defined in writing?
-
Condition
-
Comments - Further Action Required
-
Has the competence of Contractors been checked?
-
Condition
-
Comments - Further Action Required
-
Are the Water Treatment Company and any Auditors/Risk Assessors members of the Legionella Control Association?
-
Condition
-
Comments - Further Action Required
-
Is there a written scheme for controlling the risk from exposure to legionella bacteria?
-
Condition
-
Comments - Further Action Required
-
Are there regular meetings to review the effectiveness of the written scheme?
-
Condition
-
Comments - Further Action Required
-
Does the scheme contain an up-to-date plan of the system (a schematic plan is OK)?
-
Condition
-
Comments - Further Action Required
-
Does the schematic show all the Cooling Towers?
-
Condition
-
Comments - Further Action Required
-
Does schematic show all system control valves?
-
Condition
-
Comments - Further Action Required
-
Does the schematic show all standby equipment?
-
Condition
-
Comments - Further Action Required
-
Does the schematic show locations of system bleed valves?
-
Condition
-
Comments - Further Action Required
-
Does the schematic show all associated storage tanks?
-
Condition
-
Comments - Further Action Required
-
Does the schematic show all associated pipe work?
-
Condition
-
Comments - Further Action Required
-
Does the schematic show the location of chemical dosing pots and/or injection points?
-
Condition
-
Comments - Further Action Required
-
Does the schematic show the location of the system drain valve ?
-
Condition
-
Comments - Further Action Required
-
Does the schematic show the origin of the water supply?
-
Condition
-
Comments - Further Action Required
-
Does the schematic show any parts that may be temporarily out of use?
-
Condition
-
Comments - Further Action Required
-
Does the schematic contain instructions for operating the system?
-
Condition
-
Comments - Further Action Required
-
Does the scheme contain details of the precautions to be taken to control the risk of exposure to legionella bacteria?
-
Condition
-
Comments - Further Action Required
-
Does the scheme contain details of the checks that are to be carried out (and their frequency) to ensure that the scheme is effective?
-
Condition
-
Comments - Further Action Required
-
Is there a log book?
-
Condition
-
Comments - Further Action Required
-
Is the log book orderly and well presented?
-
Condition
-
Comments - Further Action Required
-
Is the tower constructed from impervious materials?
-
Condition
-
Comments - Further Action Required
-
Are drift eliminator a fitted?
-
Condition
-
Comments - Further Action Required
-
Are drift eliminators fitted correctly?
-
Condition
-
Comments - Further Action Required
-
Are the drift eliminators fitted effective?
-
Condition
-
Comments - Further Action Required
-
Is the area above the pond as enclosed as possible?
-
Condition
-
Comments - Further Action Required
-
Are all visible surfaces free from slime?
-
Condition
-
Comments - Further Action Required
-
Are all visible surfaces free from scale?
-
Condition
-
Comments - Further Action Required
-
Are all visible surfaces free from corrosion?
-
Condition
-
Comments - Further Action Required
-
Does the water flow evenly across the fill pack or other surfaces?
-
Condition
-
Comments - Further Action Required
-
Have dead legs/blind ends been removed as far as possible?
-
Condition
-
Comments - Further Action Required
-
Have redundant pipe work been removed as far as possible?
-
Condition
-
Comments - Further Action Required
-
Have redundant plant been removed as far as possible?
-
Condition
-
Comments - Further Action Required
-
Have redundant plant been removed as far as possible?
-
Condition
-
Comments - Further Action Required
-
Have redundant plant been removed as far as possible?
-
Condition
-
Comments - Further Action Required
-
Are those parts of the tower that become wet, accessible and/or removable for cleaning?
-
Condition
-
Comments - Further Action Required
-
Is the system in regular operation?
-
Condition
-
Comments - Further Action Required
-
Are there procedures in place to operate standby equipment on a rotational basis?
-
Condition
-
Comments - Further Action Required
-
Is there an operations manual for the cooling system?
-
Condition
-
Comments - Further Action Required
-
If the tower is used intermittently or is required at short notice, is it run at least once a week, so that water treatment chemicals are circulated to all parts of the system?
-
Condition
-
Comments - Further Action Required
-
If the tower is out of use for longer than a week, are there procedures in place to bring the tower back into operation safely?
-
Condition
-
Comments - Further Action Required
-
Is there a water treatment programme in place?
-
Condition
-
Comments - Further Action Required
-
Are chemicals used to control corrosion?
-
Condition
-
Comments - Further Action Required
-
Are chemicals used to control fouling?
-
Condition
-
Comments - Further Action Required
-
Are biocides used to control microbiological activity?
-
Condition
-
Comments - Further Action Required
-
Has the contractor provided evidence that their biocides are effective against legionella?
-
Condition
-
Comments - Further Action Required
-
If non-oxidising biocides are used, are two used alternately?
-
Condition
-
Comments - Further Action Required
-
Are chemicals dosed automatically?
-
Condition
-
Comments - Further Action Required
-
If dosing pumps are used are they calibrated regularly?
-
Condition
-
Comments - Further Action Required
-
Are on lines probes inspected, cleared and calibrated?
-
Condition
-
Comments - Further Action Required
-
Does the dosing/control equipment trigger an alarm in the event of a fault or out of spec result?
-
Condition
-
Comments - Further Action Required
-
Are safety data sheets held for all chemicals?
-
Condition
-
Comments - Further Action Required
-
Have COFELY COSHH assessments been carried out?
-
Condition
-
Comments - Further Action Required
-
Are eye wash bottles provided and within their expiry date?
-
Condition
-
Comments - Further Action Required
-
Has PPE been identified and provided for dosing chemicals and carrying out tests?
-
Condition
-
Comments - Further Action Required
-
Has chemical spillage been considered - are there procedures in place?
-
Condition
-
Comments - Further Action Required
-
Has chemical delivery been considered - are there procedures in place?
-
Condition
-
Comments - Further Action Required
-
Are treatment chemicals within bundled storage?
-
Condition
-
Comments - Further Action Required
-
Is there a daily check to make sure that the system is operating as described in the operations manuals?
-
Condition
-
Comments - Further Action Required
-
Is there a daily visual check of the cleanliness of the water in the system?
-
Condition
-
Comments - Further Action Required
-
Is the physical condition of the system checked at least every week?
-
Condition
-
Comments - Further Action Required
-
Is the chemical composition of the cooling and make up water monitored on a regular basis?
-
Condition
-
Comments - Further Action Required
-
Are the safe operating limits for each parameter which is being measured, known and recorded in the operating manual?
-
Condition
-
Comments - Further Action Required
-
Is the corrective action for out of limit situations known and included in the operations manual?
-
Condition
-
Comments - Further Action Required
-
Are results of all tests and checks recorded?
-
Condition
-
Comments - Further Action Required
-
Are results graphed so that trends can be seen over time?
-
Condition
-
Comments - Further Action Required
-
If there is any out of spec results or defects are actions taken to rectify, are they recorded and a clear audit trail available?
-
Condition
-
Comments - Further Action Required
-
Are test kits in tidy condition and stored safely?
-
Condition
-
Comments - Further Action Required
-
Are there instructions for each test method?
-
Condition
-
Comments - Further Action Required
-
Are all reagents within expiry date?
-
Condition
-
Comments - Further Action Required
-
Are all reagents required on site?
-
Condition
-
Comments - Further Action Required
-
Is the conductivity meter regularly calibrated?
-
Condition
-
Comments - Further Action Required
-
Is the pH meter regularly calibrated?
-
Condition
-
Comments - Further Action Required
-
Are dip slides taken at least once a week?
-
Condition
-
Comments - Further Action Required
-
Are dip slides within the expiry date and in good condition?
-
Condition
-
Comments - Further Action Required
-
Is there an incubator?
-
Is it set to 30c and recorded?
-
Is there a procedure for safe disposal of used dip slides?
-
Comments - Further Action Required
-
Are slides incubated in an incubator (30c for 48hrs)?
-
Comments - Further Action Required
-
Are samples for legionella taken on at least a quarterly basis?
-
Comments - Further Action Required
-
Is there a procedure for collecting samples for legionella testing?
-
Comments - Further Action Required
-
Does it refer to BS7592:2008?
-
Is there a procedure in the event of legionella being detected in the cooling towers?
-
Condition
-
Comments - Further Action Required
-
Have the circumstances when more frequent sampling may be required been identified and recorded?
-
Comments - Further Action Required
-
Is there a written procedure for regular cleaning and disinfection of the system?
-
Comments - Further Action Required
-
Condition
-
Comments - Further Action Required
-
Does this take place at least every 6 months?
-
Comments - Further Action Required
-
Condition
-
Comments - Further Action Required
-
Does the cleaning and disinfection procedure include initial concentration of oxidising biocide in use for the pre and post cleaning disinfection stages?
-
Comments - Further Action Required
-
Condition
-
Comments - Further Action Required
-
Does the cleaning and disinfection procedure include contact time for each disinfection stage?
-
Comments - Further Action Required
-
Condition
-
Comments - Further Action Required
-
Does the cleaning and disinfection procedure include methods for carrying out cleaning
-
Comments - Further Action Required
-
Condition
-
Comments - Further Action Required
-
Does the cleaning and disinfection procedure include the removal of packing?
-
Comments - Further Action Required
-
Condition
-
Comments - Further Action Required
-
If packs are present and cannot be removed, are there alternative methods of making sure they remain clean in place?
-
Comments - Further Action Required
-
Condition
-
Comments - Further Action Required
-
If the system is not shutdown for disinfection and cleaning every six months, lists reasons and alternative measures taken to ensure the cleanliness of the system?
-
Reason and alternative measures taken
-
Condition
-
Comments - Further Action Required
-
Are measures taken to protect staff when carrying out cleaning of the tower?
-
Comments - Further Action Required
-
Condition
-
Comments - Further Action Required
-
Is there sufficient space to perform the cleaning and maintenance tasks that are required?
-
Comments - Further Action Required
-
Condition
-
Comments - Further Action Required
-
Has handling of packing and drift eliminators when the tower is being cleaned been considered?
-
Comments - Further Action Required
-
Condition
-
Comments - Further Action Required
-
Layout and configuration. Is this an issue?
-
Comments - Further Action Required
-
Condition
-
Comments - Further Action Required
-
Has handling of chemicals been considered?
-
Comments - Further Action Required
-
Condition
-
Comments - Further Action Required
-
Has handling of salt bags been considered?
-
Comments - Further Action Required
-
Condition
-
Comments - Further Action Required
-
Is working at height considered for the routine inspection tasks considered?
-
Comments - Further Action Required
-
Condition
-
Comments - Further Action Required
-
Is working at height considered for the cleaning and disinfection?
-
Comments - Further Action Required
-
Condition
-
Comments - Further Action Required
-
Are there emergency procedures in place, in the event of an outbreak of legionnaires disease?
-
Comments - Further Action Required
-
Condition
-
Comments - Further Action Required
-
Is there sufficient space to perform the cleaning and maintenance tasks that are required?
-
Comments - Further Action Required
-
Condition
-
Comments - Further Action Required
-
Is lighting in plant rooms and on roof areas appropriate?
-
Comments - Further Action Required
-
Condition
-
Comments - Further Action Required
-
Are there procedures in place to cover lone working?
-
Comments - Further Action Required
-
Condition
-
Comments - Further Action Required