Information
-
Approval Number
-
Client
-
Address
-
Prepared By
-
Contact Phone Number 6226 1477
-
Conducted on
-
Other Staff
-
Result
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory - reinspection required after rectification works carried out
- Unsatisfactory - information to be provided
- Stop all works - contact council on 6226 1477
OHS Checklist
-
Is a First Aid Kit located in the vehicle or on site?
-
Are you working in a remote location? (satellite phone)
-
Has a Risk Assessment been undertaken for this inspection?
-
Is it safe to proceed with the inspection?
-
Have hazards been identified on site?
General
-
Has a water meter been installed
-
Water meter application to be lodged with Council
-
Photos
Internal Drainage
-
Do the Pipes have sufficient fall
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
Length of Branch
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
Floor waste, Vent and Inspection Openings
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
Has approved material been used
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
Bedding, side support and overlay
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
Filled Ground Compacted
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
Photos
External Drainage
-
Do the Pipes have sufficient fall
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
ORG and Inspection Openings
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
Concrete around boundary rises
-
Filled Ground Compacted
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
Have approved materials been used
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
Bedding, Side Support and Overlay
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
Photos
Onsite Sewage Management System
-
Tank installed in accordance with approved plans and manufacturers specifications
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
External drainage connected to tank
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
Effluent disposal system constructed/installed in accordance with Onsite Effluent Disposal Report
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
Two warning signs installed within effluent disposal area (AWTS systems only)
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
Effluent disposal area protected from possible vehicle and stock damage
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
Photos
Plumbing Final
-
External Taps securely fastened and sealed
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
Tempering valve Installed on hot water system
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
Hot water overflow taken 1 m horizontally from unit
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
Concrete Surrounds on Inspection openings and ORG
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
Water pump installed near tank
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
External Pipes Lagged
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
Vent Pipes Installed with vent cap
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
On-Site system installed to Manufacturers specifications and geotechnical Report
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
AWTS warning signs installed
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
Hot and Cold running water
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
Sealing of joints around pipes
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
Water Hammer
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory
-
Photos
Required Information
-
Required Information
- Drainage Diagram
- NSW Department of fair trading Plumbing Compliance certificate
- Commissioning Certificate for On-Site Sewage Management System
- Application/Approval to Operate OSSM
- Certificate of Installation for OSSM
Result of Inspection
-
Result of Inspection
- Satisfactory
- Satisfactory - minor works to be carried out
- Unsatisfactory - reinspection required after rectification works carried out
- Unsatisfactory - information to be provided
- Stop all works - contact council on 6226 1477
-
Comments
-
Inspected By
-
Supervisor
-
Supervisor
-
Ensure mortar/concrete mix is installed under all gullies/waste traps in accordance with AS3500
Backfill with Approved Aggregate in accordance with AS3500
Plumber to certify that Pressure test has been carried out with accordance with AS3500 -
Should you have any enquiries regarding this inspection report please contact Yass Valley Council on 6226 1477 or via email council@yass.nsw.gov.au