Mud Pump Inspection (Onshore) test2

  • Rig Number

  • Company

  • Rig Manager

  • Date of Inspection

  • Rig Phone Number

  • Rig Mobile Number

  • SPM ?

  • Liner/Piston Size ?

  • Standpipe Pressure ? (100 psi = 689.5 kpa)

  • Mud Type

Inspection Reports Undertaken

  • Was a Visual Power End Analysis carried out ?

  • Was a Complete Pump Maintenance Analysis carried out ?

  • Was an Alignment Inspection carried out ?

  • Was a Consumables Assesment carried out ?

Pump 1

  • Status

  • Pump Serial Number ?

  • Check the Discharge Pulsation Damper Pressure

  • Check the Suction Pulsation Damper Pressure

  • Check the Lube Oil Level

  • What is the condition of the Lube Oil ?

  • Is there any evidence of oil leaks from the power end ?

  • What is the condition of the Power End Breather ?

  • Is there any evidence of noise from the power end ?

  • Is there any evidence of Liner Movement ?

  • Is there any evidence of Liner Seepage ?

  • What is the condition of the Pony Rods ?

  • What is the condition of the Pony Rod Clamps ?

  • What is the condition of the Pony Rod Seals ?

  • Is the Premium Pony Rod Seal upgrade fitted

  • Is there any noise from Pony Rod area ?

  • Is there any noise from the Valves ?

  • Is there any evidence of Discharge Valve Cap movement or seepage ?

  • Is there any evidence of Suction Valve Cap movement or seepage ?

  • Are any studs missing from the Valve Retainers ?

  • Check the Valve Retainers for cracks and damage

Pump 2

  • Status

  • Pump Serial Number ?

  • Check the Discharge Pulsation Damper Pressure

  • Check the Suction Pulsation Damper Pressure

  • Check the Lube Oil Level

  • What is the condition of the Lube Oil ?

  • Is there any evidence of oil leaks from the power end ?

  • What is the condition of the Power End Breather ?

  • Is there any evidence of noise from the power end ?

  • Is there any evidence of Liner Movement ?

  • Is there any evidence of Liner Seepage ?

  • What is the condition of the Pony Rods ?

  • What is the condition of the Pony Rod Clamps ?

  • What is the condition of the Pony Rod Seals ?

  • Is the Premium Pony Rod Seal upgrade fitted

  • Is there any noise from Pony Rod area ?

  • Is there any noise from the Valves ?

  • Is there any evidence of Discharge Valve Cap movement or seepage ?

  • Is there any evidence of Suction Valve Cap movement or seepage ?

  • Are any studs missing from the Valve Retainers ?

  • Check the Valve Retainers for cracks and damage

Pump 3

  • Status

  • Pump Serial Number ?

  • Check the Discharge Pulsation Damper Pressure

  • Check the Suction Pulsation Damper Pressure

  • Check the Lube Oil Level

  • What is the condition of the Lube Oil ?

  • Is there any evidence of oil leaks from the power end ?

  • What is the condition of the Power End Breather ?

  • Is there any evidence of noise from the power end ?

  • Is there any evidence of Liner Movement ?

  • Is there any evidence of Liner Seepage ?

  • What is the condition of the Pony Rods ?

  • What is the condition of the Pony Rod Clamps ?

  • What is the condition of the Pony Rod Seals ?

  • Is the Premium Pony Rod Seal upgrade fitted

  • Is there any noise from Pony Rod area ?

  • Is there any noise from the Valves ?

  • Is there any evidence of Discharge Valve Cap movement or seepage ?

  • Is there any evidence of Suction Valve Cap movement or seepage ?

  • Are any studs missing from the Valve Retainers ?

  • Check the Valve Retainers for cracks and damage

Consumables Assessment

  • Pump 1- Consumables running hours :

  • Pump 2 - Consumables running hours :

  • Pump 3 - Consumables running hours :

undefined

Recommendations

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.