Title Page
-
Client Name
-
Location
-
Prepared by
- Steve Collett
- Jarrah Cave
- Nathan Henderson
- Connor Boon
- Matt Farrell
- Caleb Turner
-
Signature
-
Licence Number:
Electrical Inspection
Switchboard Safety
-
Photo of switchboard
-
Are mandatory RCDs (safety switches) installed on all power circuits?
-
Which circuits are not currently protected by mandatory RCDs (safety switches)?
-
Extract from AS NZS 3000 Electrical Installations (Wiring rules)
-
Are there any other circuits not protected by RCDs (safety switches)?
-
Do all safety switches operate via in built test button?
-
List of faulty safety switches
-
Are there ceramic fuses installed?
-
We recommend having ceramic fuses replaced with circuit breakers / safety switches
-
Are there exposed live parts
-
What rectification is required for compliance?
-
Is the mains cabling in good condition?
-
What rectification is required for compliance?
-
Size of mains cabling (mm2)
-
We recommended a minimum of 16mm2 mains for domestic premises.
-
Is the point of attachment in good condition and inline with current standards?
-
What rectification is required for compliance?
-
Is the switchboard structurally sound?
-
What rectification is required for compliance?
-
Is the MEN link installed and the correct size?
-
What rectification is required for compliance?
-
Extract from AS NZS 3000 Electrical Installations (Wiring rules)
-
Is the main earthing electrode installed and in good condition?
-
What rectification is required for compliance?
-
Extract from AS NZS 3000 Electrical Installations (Wiring rules)
-
Unable to locate
-
Is there potential asbestos within the switchboard?
-
See Queensland Government Department of Health for further information: https://www.asbestos.qld.gov.au/sites/default/files/asbestos-health-risks-guidance-note.pdf
-
Is the switchboard adequately labelled?
-
Does the switchboard have surge protection?
-
Surge protection devices are not mandatory, but recommended
-
Is the switchboard cabling TPS equivalent?
-
Extract from Worksafe Queensland report on VIR and TRS cabling:
Smoke Alarm Safety
-
Are smoke alarms installed at the property?
-
Smoke alarm installation required to meet current legislation?
-
Extract from QLD Fire and Emergency Services Queensland Government Smoke Alarm Legislation
-
Are the smoke alarm photoelectric or ionization?
-
Are the smoke alarms within 10 years of manufacture date?
-
Do the smoke alarms operate under test conditions?
-
Are smoke alarms installed in the correct locations in accordance with Queensland Government regulations?
-
Are all smoke alarms interconnected?
-
Do the installated smoke alarms meet all of the above compliance conditions?
-
What rectification is required for compliance?
-
Queensland Government Smoke Alarm Legislation:
Functionality
-
Are all light fittings in good working order?
-
List faulty fittings and locations
-
What is the general condition of light fittings?
- GOOD: All / majority of light fittings are new and in good condition.
- FAIR: Some new light fittings in good condition. Some older light fittings but still functional
- POOR: Many older light fittings but still functional
-
Are all lights switches, power points, tv points and data outlets in good physical condition?
-
List damaged outlets and locations
-
What is the general condition of power points and light switches?
- GOOD: All / majority of power points and lights switches are new and in very good condition
- FAIR: Some new power points and light switches. Some older power points and light switches, still functional but showing signs of age / yellowing.
- POOR: Mostly older power points and light switches, still functional but showing signs of age / yellowing.
Appliances
Cooking Appliances
-
What cooking appliances are at the property?
-
Are cooking appliances in good working order?
-
List of faulty appliances and details
Hot water system
-
Is the hot water system gas or electric?
-
General Condition of hot water system?
-
Details of condition
-
Picture of hot water system
Air Conditioning Units
-
Are there air conditioning units at the property?
-
Are the air conditioning units in good working order?
-
List faulty unit, size and location
-
Do the air conditioning units have a local isolator installed?
-
Extract from AS NZS 3000 Electrical Installations (Wiring rules): Air conditioning isolator requirements:
Solar
-
Is there a solar system currently installed?
-
Photo of the inverter
-
Is the inverter is good condition?
-
Photo of solar panels
-
Are DC isolators installed?
-
Are the DC isolators in good condition?
-
What rectification is required for compliance?
-
What rectification is required for compliance?
-
Is the cabling secure and correctly installed?
-
What rectification is required for compliance?
-
Are the panel frames earthed?
-
What rectification is required for compliance?
-
Are the panels clean?
Outbuildings
-
Are there any sheds / outbuildings at the property?
-
Is the switchboard / subboard in good condition
-
What rectification is required for compliance?
-
Is cabling installed with sufficient mechanical protection
-
What rectification is required for compliance?
-
Are all light fittings in good working order?
-
List faulty fittings and locations
-
Are all power points in good physical condition?
-
List damaged outlets and locations