Title Page

  • Client Name

  • Location

  • Prepared by

  • Signature

  • Licence Number:

Electrical Inspection

Switchboard Safety

  • Photo of switchboard

  • Are mandatory RCDs (safety switches) installed on all power circuits?

  • Which circuits are not currently protected by mandatory RCDs (safety switches)?

  • Extract from AS NZS 3000 Electrical Installations (Wiring rules)

  • Are there any other circuits not protected by RCDs (safety switches)?

  • Do all safety switches operate via in built test button?

  • List of faulty safety switches

  • Are there ceramic fuses installed?

  • We recommend having ceramic fuses replaced with circuit breakers / safety switches

  • Are there exposed live parts

  • What rectification is required for compliance?

  • Is the mains cabling in good condition?

  • What rectification is required for compliance?

  • Size of mains cabling (mm2)

  • We recommended a minimum of 16mm2 mains for domestic premises.

  • Is the point of attachment in good condition and inline with current standards?

  • What rectification is required for compliance?

  • Is the switchboard structurally sound?

  • What rectification is required for compliance?

  • Is the MEN link installed and the correct size?

  • What rectification is required for compliance?

  • Extract from AS NZS 3000 Electrical Installations (Wiring rules)

  • Is the main earthing electrode installed and in good condition?

  • What rectification is required for compliance?

  • Extract from AS NZS 3000 Electrical Installations (Wiring rules)

  • Unable to locate

  • Is there potential asbestos within the switchboard?

  • See Queensland Government Department of Health for further information: https://www.asbestos.qld.gov.au/sites/default/files/asbestos-health-risks-guidance-note.pdf

  • Is the switchboard adequately labelled?

  • Does the switchboard have surge protection?

  • Surge protection devices are not mandatory, but recommended

  • Is the switchboard cabling TPS equivalent?

  • Extract from Worksafe Queensland report on VIR and TRS cabling:

Smoke Alarm Safety

  • Are smoke alarms installed at the property?

  • Smoke alarm installation required to meet current legislation?

  • Extract from QLD Fire and Emergency Services Queensland Government Smoke Alarm Legislation

  • Are the smoke alarm photoelectric or ionization?

  • Are the smoke alarms within 10 years of manufacture date?

  • Do the smoke alarms operate under test conditions?

  • Are smoke alarms installed in the correct locations in accordance with Queensland Government regulations?

  • Are all smoke alarms interconnected?

  • Do the installated smoke alarms meet all of the above compliance conditions?

  • What rectification is required for compliance?

  • Queensland Government Smoke Alarm Legislation:

Functionality

  • Are all light fittings in good working order?

  • List faulty fittings and locations

  • What is the general condition of light fittings?

  • Are all lights switches, power points, tv points and data outlets in good physical condition?

  • List damaged outlets and locations

  • What is the general condition of power points and light switches?

Appliances

Cooking Appliances

  • What cooking appliances are at the property?

  • Are cooking appliances in good working order?

  • List of faulty appliances and details

Hot water system

  • Is the hot water system gas or electric?

  • General Condition of hot water system?

  • Details of condition

  • Picture of hot water system

Air Conditioning Units

  • Are there air conditioning units at the property?

  • Are the air conditioning units in good working order?

  • List faulty unit, size and location

  • Do the air conditioning units have a local isolator installed?

  • Extract from AS NZS 3000 Electrical Installations (Wiring rules): Air conditioning isolator requirements:

Solar

  • Is there a solar system currently installed?

  • Photo of the inverter

  • Is the inverter is good condition?

  • Photo of solar panels

  • Are DC isolators installed?

  • Are the DC isolators in good condition?

  • What rectification is required for compliance?

  • What rectification is required for compliance?

  • Is the cabling secure and correctly installed?

  • What rectification is required for compliance?

  • Are the panel frames earthed?

  • What rectification is required for compliance?

  • Are the panels clean?

Outbuildings

  • Are there any sheds / outbuildings at the property?

  • Is the switchboard / subboard in good condition

  • What rectification is required for compliance?

  • Is cabling installed with sufficient mechanical protection

  • What rectification is required for compliance?

  • Are all light fittings in good working order?

  • List faulty fittings and locations

  • Are all power points in good physical condition?

  • List damaged outlets and locations

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.