Title Page

  • Building

  • Elevator #

  • Conducted on

  • Prepared by

  • Location

Inside of Car

  • Door reopening device

  • Stop switches

  • Operating control devices

  • Sills and car floor

  • Car lighting and receptacles

  • Car emergency signal

  • Car door or gate

  • Door closing force

  • Power closing of doors or gates

  • Power opening of doors or gates

  • Car vision panels and glass car doors

  • Car enclosure

  • Emergency exit

  • Ventilation

  • REFERENCE: Elevator signs and Operating Device Symbols in Good Working Condition
    [This is an example of how you can use iAuditor to include best practice reference images in your templates to assist with inspections]

    51So8cLRFhL.jpg
  • Signs and operating device symbols

  • Rated load, platform area, and data plate

  • Standby power operation

  • Restricted opening of car/hoistway doors

  • Car ride<br>

  • Earthquake inspection/test

Top of Car

  • Top-of-car stop switch

  • Car top light and outlet

  • Top-of-car operating device

  • Top-of-car clearance and refuge space

  • Normal terminal stopping device

  • Final and emergency terminal stopping devices

  • Car leveling and anti-creep devices

  • Top emergency exit

  • Floor, and emergency numbering

  • Hoistway construction

  • Hoistway smoke control

  • Pipes, wiring, and ducts

  • Windows/projections/setbacks/recesses

  • Hoistway clearances

  • Multiple hoistway

  • Traveling cables and junction boxes

  • Door and gate equipment

  • Car frame and stiles

  • Guide rails, fastening and equipment

  • Governor rope

  • Governor releasing carrier

  • Wire rope fastening and hitch plate

  • Suspension rope

  • Top counterweight clearance

  • Car, overhead, and deflector sheaves

  • Broken rope, chain, or tape switch

  • Crosshead data plate

  • Counterweight/counterweight buffer

  • Counterweight safeties

  • Compensating ropes and chains

  • Earthquake inspection/test

Machine Room

  • Access to machine space

  • Headroom

  • Lighting and receptacles

  • Machine space

  • Housekeeping

  • Ventilation

  • Fire extinguisher

  • Pipes, wiring, and ducts

  • Guarding of exposed auxiliary equipment

  • Numbering of elevators, machines, and disconnect switches

  • Disconnecting means and control

  • Controller wiring, fuses, grounding, etc.

  • Governor, overspeed switch, and seal

  • Code data plate

  • Static control

  • Overhead beam and fastenings

  • Drive machine brake

  • Traction drive machines

  • Gears, bearings and flexible couplings

  • Winding drum machine and slack cable device

  • Belt or chain-drive machine

  • Motor generator

  • Absorption of regenerated power

  • AC drives from a DC source

  • Traction sheaves

  • Secondary and deflector sheaves

  • Rope fastenings

  • Terminal stopping devices

  • Car and counterweight safeties

  • Maintenance records

  • Earthquake inspection/test

Completion

  • Overall Recommendation

  • Name & Signature of Maintenance Personnel

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.