Title Page

  • Client

  • Site address

  • Description of works

  • Date

  • Name of person carrying out the inspection

  • Site manager

BASE

  • Is the scaffold on a solid base

  • Does each standard have a base plate

  • Are sole plates of correct dimensions being used

  • Is the sole plate on solid ground

GEOMETRY

  • Are the standards vertical

  • Are the ledgers and transoms horizontal

  • Are the joints in the standards staggered and not in the same bay

  • Are the joints no more than a 1/3 into a bay

  • Are the transoms correctly spaced

PLATFORMS

  • Are the supports correct and evenly distributed

  • Is the overhang a min. of 50mm (max 150mm for 38mm boards)

  • Are the boards in good condition

  • Are lapped boards safe

  • Are the boards secure

BRACING

  • Is the ledger bracing fitted on alternate pairs of standards for the full height of the scaffold

  • Is the longitudinal or façade bracing fixed to every lift

  • Is the longitudinal or facade brace fitted along the face of the scaffold at least every 5 bays

  • Is the longitudinal or facade bracing set at between 35deg and 55deg

TUBES AND FITTINGS

  • Are the tubes and fittings in good condition

  • Have the correct couplers been used

  • Are all fittings tightened sufficiently

  • Are check couplers fitted as required

ACCESS

  • Is access provided to full height of the scaffold

  • Is the ladder at a slope of 75deg or 1:4 ratio base to height

  • Is the head securely tied and feet on a firm and level base

  • Do the ladders rise at least 1.05m above each platform

  • Are the ladders undamaged

LOADING

  • Is the erected scaffold correct for its intended use

  • Are loads on the platform evenly distributed

  • Are stacked materials secure

TIES

  • Have sufficient ties been used in accordance with current regulations

  • Are ties fixed with the right angle couplers

  • Are ties attached to both inner and outer standards or ledgers

GUARD RAILS AND TOE BOARDS

  • Are the rails secured to the inside of standards

  • Are rails fixed at least 950mm above the level of the platform

  • Are toe boards fitted to all platforms and at least 150mm high

  • Are toe boards secured to the inside of the standard

  • Is intermediate side protection provided so that there is no vertical gap exceeding 470mm

SCAFFTAG

  • Is the Scafftag prominently displayed at all access points

  • Have the details on the Scafftag been completed correctly

  • Have the inspections been signed by an authorised person

  • Are the inspection frequencies in accordance with the regulations

SIGN OFF

  • Signature

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.