Information
-
Document No.
-
Audit Title
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
-
Site Address?
-
Site location - Street, Premises, Other?
-
Date of Audit?
General
-
Start Cards filled out?
-
Can you talk through all the hazards onsite. Show me on the start card where you would put any hazards if not covered by the SWMS?
-
Blue book onsite and available?
-
Can you tell me where in the blue book would you find MSDS, Emergency Contact Details, SWMS, Calibration records, Ladder Inspection Records.
-
-
Do all members of crew have White cards, First aid certs, ID(enable), Traffic management Tickets, Working At Heights, Pole Top Rescue, EP licence or any other mandatory tickets onsite and available?
-
Are First aid kits onsite and all items in date?
-
Is there a sharps kit onsite?
-
Is there a spill kit onsite?
Civil
-
Does one member of the crew have a valid implement traffic management ticket
-
Is traffic management set up according to a scenario from the blue book
-
Have you done a Walk\Drive through? ( to ensure the site makes sense to the public - Pedestrian and vehicular)
-
Pedestrian management accounted for ?(pedestrians not put in danger or directed in an un safe manner)
-
Are all areas barricaded and safe to the public?
-
Is there a Dig permit onsite and filled out correctly?
-
Have you performed a pre start for any plant and is the plant register up to date.?
-
Can you explain what you do if conditions change? (weather, traffic, third party crew starts to work near by)?
-
Is all plant service history onsite and in date?
-
Gas detector onsite, Calibrated and in blue book register?
-
Is there a cable locator onsite?
-
Is PPE being worn, i.e hard hats near plant, Safety Glasses, Gloves, steel cap boots in good condition
-
Is there any ACM onsite, are their trained people and site set up safe. including correct signage, Supervisor within 20min and licence available?
-
Are the DBYD onsite and on a readable device?
-
Please explain the local assets in relation to the DBYD?
-
Can you explain one of the symbols on the DBYD?
-
Is the lic dug to depth, 300mm from top of conduit to ground level.?<br>If digging in the street network is it to depth 450mm from top of conduit to ground level?
-
Is the lic placed in accordance with the PCD guidelines. i.e 100mm from corners, 150mm from taps, 150mm from power sources, 1000mm from gas meters and 1500mm from gas bottles?
-
Is the reinstatement up to an acceptable level?
-
Is the customer aware of the works onsite?
-
Are pit entry/exits compliant regarding location and spigots fit flush with pit wall
Aerial
-
Do both members of the crew have like for like qualification i.e. Electrical practitioners, linesmen
-
Do both members of the crew have IP tickets?
-
Are LV gloves being used and in test (12 months)?
-
Do both members of the crew hold valid pole top rescue(12 months) and working at heights qualifications(2 years)
-
Can you explain the SAD's zone i.e zone 1, Zone 2 safe approach distance (no closer than 600mm from LV)
-
Can you tell me what the TS-02 is? What does it mean to me?
-
Is there a rescue kit onsite and placed at the base of the pole?
-
Are ladders Tas networks tested and no signs of physical wear?
-
Traffic management tickets held and onsite.
-
Traffic management setup to plan
-
Height safety equipment (harnesses in date and visually tested)
Internal Installer
-
Have you spoken to the EU about NTD locations and run through the 10 min guide?
-
Have you asked the EU about any unknown hazards, i.e pipes in render etc.?
-
is the roof space or sub floor access needed? Has the power been isolated, tagged and the EU made aware?
-
Do you know how to isolate the power, i.e sub boards, no main isolation switches
-
Do you have a bore scope and stud\electricity finder?<br>
-
Will any services pose a hazard to you during the installation, if so is there a better cable path?