Title Page
-
Site conducted
-
Conducted on
-
Prepared by
-
Location
Safety Inspection/Audit
Housekeeping
-
Is debris secured and/or removed from floors?
-
Is lighting adequate for workers?
-
Are materials stored and secured in a safe manner?
-
Are all vertical rebar/impalement hazards capped?
Access/Egress Paths
-
Are exits clearly marked?
-
Are the egress passageways and stairs and doors adequate/unobstructed?
-
Are all access/egress pathways at least three feet wide?
-
Are all access/egress pathways clear of equipment, material and debris?
-
Are all access/egress pathways free of tripping hazards?
Scaffolds/Stair Towers
-
Is the scaffold competent person (CP) on site when scaffolds are in use?
-
Was the daily inspection performed and is the inspection tag signed by CP
-
Is the scaffold in plumb and level?
-
Are guard rails in place?
-
Is the working platform fully planked and secured?
-
Is the working platform free of tripping hazards, excess material and debris?
-
Where required, is netting installed, secured to scaffold and free of tears?
Fire Protection/Prevention
-
Are all barricades built with fire retardant wood?
-
Is the FR stamp visible?
-
Is a fully charged 20 lb. ABC fire extinguisher within the barricaded area?
-
Are all fire extinguishers inspected monthly?
-
Are all fire extinguishers fully charged?
-
Are all first aid kits and eyewashes inspected monthly?
-
Are all first aid kits and eyewashes fully stocked?
-
Is any hot work (welding, burning or producing sparks) being performed?
-
Is the hot work permit available?
-
Is there a fire guard with a valid FDNY F-60 certificate?
-
Does the torch operator have a valid FDNY G-60 certificate?
-
Are welding shield in place to protect other workers and the public?
-
Is there a fully charged fire extinguisher within 35 feet of the hot work operation?
-
Is the area free of combustibles?
-
Does the welder/torch operator have the correct PPE?
-
Does the fire guard have the correct PPE?
-
Are compressed gasses/fuel/paint stored in proper containers?
-
Are compressed gasses/fuel/flammables stored in UL approved cabinets?
-
Is there an approved FDNY storage permit?
Compressed Air (use N/A if there are no compressed air in use)
-
Are whip checks being used?
-
Are hoses free of defects?
-
Is an OSHA safety device on compressor lines greater than ½” I.D.?
-
Is a fully charged and inspected fire extinguisher within 25 feet of compressor?
Fall Protection
-
Is the leading edge adequately protected?
-
Are loads along perimeter secured?
-
Are holes in the floors covered and marked?
-
Are guard rails properly set up with top rail, mid rail, toe board?
-
Are PFAS Harnesses used when exposed to 6-foot fall exposure?
-
Are PFAS Harnesses worn properly?
-
Is the PFAS Harness tie off point adequate?
-
Are Control Access Zones (CAZ) being used, where required?
-
Is CAZ properly marked out?
-
Is CAZ monitor in place?
-
Are proper warning signs in place?
Excavations/Trenches (use N/A if there are no excavations/trenches)
-
Was 811 called?
-
Are utility mark outs in place?
-
Are adjacent buildings undermined or in danger of being undermined?
-
Was the daily inspection by the competent person performed?
-
Are materials/equipment located away from unprotected trench?
-
Is there shoring installed if excavation/trench is deeper than 5 feet?
-
Is the shoring adequate?
-
Is there adequate egress from excavation/trench?
-
Is there fall protection (required at > 6 feet)?
Electrical Safety
-
Are GFCI’s in use?
-
Are all extension cords free of defects?
-
Are all tool cords free of defects?
-
Are ground pins on cords in place and not missing?
-
Are electrical panels and boxes closed or otherwise protected?
-
Are LO/TO procedures being used correctly?
-
Are electrical lines and facilities being protected from contact?
Construction Equipment
-
Is the swing radius barricaded?
-
Are the backup warning devices working?
-
Is there roll over protection?
-
Is there a fire extinguisher on vehicles?
-
Was the daily inspection performed?
-
Is the equipment parked/safeguarded when not in use?
Ladders
-
Are all ladders in use inspected daily?
-
Are ladders in good shape and free of defects?
-
Are ladder permits being issued (for new DB projects)?
-
Are ladders properly set up on level surface?
-
Are A-frame ladders being used fully open?
-
Are extension ladders not separated?
-
Are ladders footed or cleated at bottom?
-
Are ladders secured from movement at top?
-
Do ladders extend 3 feet past the landing area?
Confined Space
-
Are confined spaces properly marked?
-
Is the confined space entry program in place?
-
Is a confined space permit posted at entry point?
-
Is the attendant on duty at entry point?
-
Is a calibrated gas meter available and in use at entry point?
-
Is the rescue tripod properly set up?
-
Are there any hazards not identified on the confined space permit?
PPE
-
Are all workers wearing hard hats?
-
Are all workers wearing reflective vests?
-
Are all workers wearing safety glasses?
-
Are all workers wearing work boots with safety toe?
-
Are workers using or near high noise tools wearing hearing protection?
-
Are workers who are using grinders, chipping hammers or other tools creating flying debris wearing face shields?
Street Operations/MPT
-
Is MPT properly set up per drawings/permit?
-
Are DOT permits up to date and available?
-
Are certified flaggers being used as needed to move equipment?
-
Are concrete jersey barricades in use against traffic (for new DB projects)?
-
Is MPT set up to keep pedestrians out work area?
-
Are proper traffic warning and directional signs set up?
-
Are there signs to direct pedestrians?
-
Is the entry to MPT area closed when not moving equipment/material in or out?
-
Is a 5-foot-wide pedestrian walkway maintained?
-
Are working warning devices mounted on traffic side of street MPT?
-
Are MPT barriers, barricades, fences and netting in good working order?