Information

  • Site Address:

  • Conducted on

  • Conducted by

  • Location

External

  • Are the overall slab dimensions as per plan?

  • Has the slab an even surface?

  • Is the slab surface clean of chalking?

  • Are there any slab overhangs?

  • Are all step downs correct?

  • Are all parapets strapped/braced as per plan

  • Are additional sumps required?

  • Are eave dimentions as per plan?

  • Isthe frame designed as per elivations?

  • Additional Comments:

  • Photo if required

Entry

  • Are all room dimensions as per plan? (Ceiling heights and overall dimentions)

  • Is the correct front door unit installed?

  • Is the portico step down correct?

  • Are all portico posts installed plumb/level and as per plan?

  • Additional comments:

PANTRY

  • Are all room dimensions as per plan? (Ceiling heights and overall dimentions)

  • Have studs been placed under loads

  • Have all ceiling plaster trimmers and change of direction trimmers been installed?

  • Are all internal corners plumb and level?

  • Has bracing been placed as per engineering?

  • Are all windows and door dimensions correct? (width/height/glazing)

  • Have plumbing wastes been located correctly?

  • Are all lower roofs completed correctly and as per truss layout?

  • Additional Comments:

  • Photo if required

LAUNDRY

  • Are all room dimensions as per plan? (Ceiling heights and overall dimentions)

  • Have studs been placed under loads

  • Have all ceiling plaster trimmers and change of direction trimmers been installed

  • Are all internal corners plumb and level

  • Has bracing been placed as per engineers

  • Are all windows and door dimensions correct? (width/height/glazing)

  • Have plumbing wastes been located correctly?

  • Are all lower roofs completed correctly and as per truss layout?

  • Additional Comments:

  • Photo if required

LIVING ROOM

  • Are all room dimensions as per plan? (Ceiling heights and overall dimentions)

  • Have studs been placed under loads

  • Have all ceiling plaster trimmers and change of direction trimmers been installed

  • Are all internal corners plumb and level

  • Has bracing been placed as per engineering?

  • Are all windows and door dimensions correct? (width/height/glazing)

  • Are all lower roofs completed correctly and as per truss layout?

  • Additional Comments:

  • Photo if required

KITCHEN , DINING AREA

  • Are all room dimensions as per plan? (Ceiling heights and overall dimentions)

  • Have studs been placed under loads?

  • Have all ceiling plaster trimmers and change of direction trimmers been installed?

  • Are all internal corners plumb and level

  • Has bracing been placed as per engineering?

  • Are all windows and door dimensions correct? (width/height/glazing)

  • Have plumbing wastes been located correctly

  • Are all lower roofs completed correctly and as per truss layout?

  • Additional Comments:

  • Photo if required

GARAGE

  • Are all room dimensions as per plan? (Ceiling heights and overall dimentions)

  • Have studs been placed under loads?

  • Have all ceiling plaster trimmers and change of direction trimmers been installed?

  • Are all internal corners plumb and level?

  • Has bracing been placed as per engineering?

  • Have roller door noggins been installed as per detail?

  • Are all lower roofs completed correctly and as per truss layout?

  • Check garage boundary wall height. Does it comply to town planing?

  • Additional Comments:

Structural Steel

  • Have all beams been installed as per plan? (Size/location)

  • Have all steel connections been installed as per Engineering?

  • Have all steel connections and cleans been welded and completed?

  • Have all steel struts been installed?

  • Additionally comments:

  • Photo if required

Joist and Sub floor

  • Has all chipboard flooring been glued and nailed off?

  • Have all joist been installed as per joist layout?

  • Have all brackets and bracing been installed as per joist layout?

  • Have all strong backs been installed correctly and connected to required beams?

  • Additional Comments:

Party Wall

  • Has the party wall been inspected by the surveyor?

  • Is the party wall installed as per spec?

  • Is the party wall damaged in any section?

  • Does the party wall terminate at the end of the framed cavity?

  • Are clips installed as per spec?

  • Does the party wall terminate at the top of parapet/roof?

  • Is there adequate fire check coverage between ground floor and first floor? (Min 150mm bellow ground floor top plate)

  • Additional comments:

  • Photo if requried

STAIR VOID

  • Do all lower walls line up straight to upper walls?

  • Are all room dimensions as per plan? (Ceiling heights and overall dimentions)

  • Are all void dimensions as per plan?

  • Do we have the required head room between ceiling and stairs?

  • Additional Comments:

STUDY

  • Are all room dimensions as per plan? (Ceiling heights and overall dimentions)

  • Have studs been placed under loads

  • Have all ceiling plaster trimmers and change of direction trimmers been installed

  • Are all internal corners plumb and level

  • Has bracing been placed as per engineers

  • Are all windows and door dimensions correct? width and height?

  • Are all lower roofs completed correctly and as per truss layout?

  • Additional Comments:

  • Photo if required

MASTER BEDROOM

  • Are all room dimensions as per plan? (Ceiling heights and overall dimentions)

  • Have studs been placed under loads

  • Have all ceiling plaster trimmers and change of direction trimmers been installed

  • Are all internal corners plumb and level

  • Has bracing been installed as per engineers

  • Are all windows and door dimensions correct? (width/height/glazing)

  • Have studs been placed at 300cts at end of WIR

  • Are all lower roofs completed correctly and as per truss layout?

  • Additional Comments:

  • Photo if required

MASTER ENSUITE

  • Shower step down accurate and correct and allowed for shelf wall if required?

  • Are all room dimensions as per plan? (Ceiling heights and overall dimentions)

  • Have studs been placed under loads?

  • Have all ceiling plaster trimmers and change of direction trimmers been installed?

  • Are all internal corners plumb and level?

  • Has bracing been placed as per engineering?

  • Are wastes and plumbing located in correct positions

  • Is shower box located correctly and studs placed at 300cts around shower?

  • Are all windows and door dimensions correct? (width/height/glazing)

  • Are niches/shelf walls placed in correct position and correct size

  • Are all lower roofs completed correctly and as per truss layout?

  • Additional Comments:

  • Photo if required

BEDROOM 2

  • Are all room dimensions as per plan? (Ceiling heights and overall dimentions)

  • Have studs been placed under loads

  • Have all ceiling plaster trimmers and change of direction trimmers been installed

  • Are all internal corners plumb and level

  • Has bracing been installed as per engineering

  • Are all windows and door dimensions correct? (width/height/glazing)

  • Are all lower roofs completed correctly and as per truss layout?

  • Additional Comments:

  • Photo if required

BEDROOM 3

  • Are all room dimensions as per plan? (Ceiling heights and overall dimentions)

  • Have studs been placed under loads

  • Have all ceiling plaster trimmers and change of direction trimmers been installed

  • Are all internal corners plumb and level

  • Has bracing been installed as per engineering

  • Are all windows and door dimensions correct? (width/height/glazing)

  • Are all lower roofs completed correctly and as per truss layout?

  • Additional comments:

  • Photo if required

BEDROOM 4

  • Are all room dimensions as per plan? (Ceiling heights and overall dimentions)

  • Have studs been placed under loads

  • Have all ceiling plaster trimmers and change of direction trimmers been installed

  • Are all internal corners plumb and level

  • Has bracing been placed as per engineers

  • Are all windows and door dimensions correct? (width/height/glazing)

  • Are all lower roofs completed correctly and as per Plan?

  • Additional comments:

  • Photo if required

BATHROOM

  • Shower stepdown accurate and allowed for shelf wall if required?

  • Are all room dimensions as per plan? (Ceiling heights and overall dimentions)

  • Have studs been placed under loads

  • Have all ceiling plaster trimmers and change of direction trimmers been installed

  • Are all internal corners plumb and level

  • Has bracing been placed as per engineers

  • Are wastes and plumbing located in correct positions

  • Is shower waste located correctly and studs placed at 300cts around shower

  • Are all windows and door dimensions correct? (width/height/glazing)

  • Are niches/shelf walls placed in correct position and correct size

  • Are all lower roofs completed correctly and as per truss layout?

  • Additional Comments:

  • Photo if required

Roof

  • Are all trusses installed as per truss layout?

  • Is all roof speed bracing completed as per truss layout?

  • Isall speed brace wrapped under top plates correctly?

  • Are all multi grips/truss ties/ creeper connectors installed as per truss layout?

  • Are all valley boards installed?

  • Are all slip blocks installed to all valley trusses?

  • Are all bottom chord ties installed as per roof layout?

  • Are all shear blocks installed?

  • Are all L brackets installed where required?

  • Are tail struts installed to all hips?

  • Do all girder trusses have the required double studs under them?

  • Has the heating unit been allowed for and designed?

  • Additional comments:

  • Photo if required

GENERAL POINTS ON FRAME

  • Frame pass?

  • Overall quality of frame

  • This frame has been inspected by

  • The frame items have been completed by

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.