Frame QA

  • Bottom plates have less than 10mm overhang.

  • Bottom plates fixed down correctly (1200mm c/c & 70mm in from slab edge)

  • Meter box is in the correct location, plumb and framed out.

  • Internal frame layout as per plans. Mark all openings and noggins for fixtures using spray paint.

  • Ceiling Heights are correct

  • Walls and structural steel plumb (Tolerance is 4mm over 2m).

  • All external wall intersections have been nailed off straight

  • Load point studs laminated correctly (300mm C-C) and supporting girder trusses.

  • Bulkheads and plaster openings installed as per plans, plumb and level

  • Wet area noggins for NCC Accessibility completed (detailed on plans)

  • Soap niche framed out as per plans

  • Stair nib walls are the correct height, plumb, straight and braced accordingly.

  • All plumbing waste and stack points located in correct location

  • All bracing nailed off correctly (check against engineering)

  • L-Brackets installed (max 1800c/c) and not nailed home

  • Shear blocks installed as required.

  • I Beam/Possies installed correctly

  • Joist hanger brackets installed flush to bottom cord

  • Solid beams installed correctly including connections

  • Stair void wall line up plumb and straight (Critical )

  • Manhole trimmers have been installed. Mark location on floor.

  • All truss and change of direction noggins installed & flush with bottom chord

  • Trusses installed correctly, level and plumb (50mm tolerance for plumb Trusses)

  • Windows and sliding doors are installed level/plumb and opening from the correct way

  • External doors flashed correctly (refer detail for any sliding door, timber sill requires DPC)

  • 10mm Bulb seal on windows/doors installed to expansion join location on plans

  • Overlooking windows installed as per plans (if not required, select pass)

  • Sumps in box gutters have been framed out correctly (min sump size = width of box gutter x 450mm L x 150D )

  • Parapet walls to finish min 75mm above roof sheet height

  • Parapet walls are plumb

  • Lear gutter boards installed 300mm up the rake of roof

  • Site swept, rubbish placed in cage, material stacked neatly in garage

  • Other items to be rectified

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.