Information

  • Document No.

  • Client / Site (inc Site Code)

  • Location
  • Review Panel Members

Rules

Rules

  • You must walk each site and every space that is currently marked or you believe could be marked as a 'Confined Space'. Each space needs to be assessed and have appropriate signage installed or if deemed no longer required removed.

  • Access to all confined spaces shall only be made after completion of the appropriate documented 'Confined Space Permit'.

  • You must either, remove or remark and number each space assessed, at each entry point, and attach a photo of all the entry points and signage both pre and post assessment and marking. This applies to all spaces assessed not just those assessed as confined spaces as our ability to show the methodology behind why we no longer deem a space to be a confined space is equally important.

  • Please ensure you locate and review and previous 'Confined Space' site registers before undertaking this assessment.

  • In a situation where you journey down to get to a tunnel. The ranking of the tunnel will apply to all area's on that level and above including the elevator tower. The ranking for the boot will similarly also apply to all levels below it.

  • Please refer to the external OSHEM Report (if you do not have this your Health & Safety Advisor will be able to supply a copy). In summary the following general overview classification (without considering the individual differences) was provided on each storage type. It is recommended you read this report prior or at least review similar type storages. Please note similar type storage ie. design will carry in most cases a similar ranking ie. S122 and S098.

    The OSHEM report assessed and determined the following storage types, areas and spaces as-
    Not a confined space:

    SA Silo's, Haunstrop Silo's, Perrin Shed, Hex Bin (SX16), A200 Reclaim Pit, C288 Tunnel, S095 Tunnel, S068, S100, A299 Tunnel, S082 Tunnel, C409 Short Tunnel, S150 Tunnel, S054 Tunnel, A191 Tunnel, C351, S300, C409, S052, S122, S300 Tunnel.

    The OSHEM report assessed and determined the following storage types, areas and spaces as-
    Confined Spaces.

    Munroe Silo's, A200 Squat Bin, S060, C288 Boot Pit, S095 Boot Pit, D150 Boot Pit, A191 Boot Pit, CLS Blue Elevator Boot Pit, C1100 Cotton Hopper, A299 Boot Pit, S082 Boot Pit, S150 Boot Pit, S054 Boot Pit, A191 Boot Pit, Weighbridge Pit's, A23 Boot Pit, S122 Boot Pit, E270 Boot Pit, S300 Boot Pit

    Please make note of the other hazards and risks identified in the external consultant's OSHEM report and check to see if your area's and/or plant have some of the identified risks present and if so please address.

  • The numbering and lettering identification sequence for each space can be found in the top left hand corner once each space is identified and is automatically generated by the audit tool. Sequences will look as follows: Weighbridge Pit (WB1,WB2etc), Bin Bases (BB1, BB2 etc).

Guidelines

  • Forced ventilation does not make something “not” a confined space (i.e. fans that start automatically when the lights are turned on).

    If a tunnel or boot has valves in it, it will typically be seen as being designed to be occupied by a person. Conversely, bin bases, hoppers and under weighbridge spaces are not.

    A shed, sealed or not is typically not considered a confined space.

    2 points of entry and exit is not mandatory for something not to be deemed a confined space.

Register

  • Weighbridge Pit - WB

  • Weighbridge Pit - WB
  • Storage Code

  • Location (be detailed describe in words where the space is).

  • Image of Space being assessed (both before and after assessment and marking). Please include a photo of the space and each sign prior to assessment and then post assessment once it has been either re-marked or removed.

  • Criteria for classification of a Confined Space (ref' AS 2865__2009)
  • Is this space enclosed or partially enclosed?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks which may need to have additional controls put in place before entering the space.

  • Is this space not designed or intended to be occupied by a person?

  • Is or is intended to be at normal atmospheric pressure while any person is in the space?

  • Is there a risk of one or more of the following? An oxygen concentration outside the safe oxygen range, A concentration of airborne contaminants that may cause impairment, loss of consciousness or asphyxiation, A concentration of airborne contaminants that may cause injury from fire or explosion, Engulfment in a stored free flowing solid or a rising level of liquid that may cause suffocation or drowning.

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks which may need to have additional controls put in place before entering the space.

  • Is this space in Victoria?

  • This Space meets all the criteria for a Confined Space and must be risk assessed and controls implemented before entry to the space can be effected.

  • Does the space have a restricted entry or exit?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks which may need to have additional controls put in place before entering the space.

  • This Space meets all the criteria for a Confined Space and must be risk assessed and controls implemented before entry to the space can be effected.

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks which may need to have additional controls put in place before entering the space.

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks which may need to have additional controls put in place before entering the space.

Risk Assessment

  • What are the inherent hazards and risks of this space? (tap for drop down menu)

  • Are there other inherent hazards and risks of this space?

  • Review any previous documented risk assessments for this space. A revised risk assessment must now be completed that considers the level of safety management from current existing controls, as well as the predicted enhanced level of safety that could be achieved upon implementation of further higher order controls. The ranking score and risk mitigation measures should be determined through application of the GrainCorp Risk Assessment Matrix and Hierarchy of Controls.

    C1ACCFA3-91F2-41E2-8BC7-E7E0CE02ADBA.jpg
  • What is the Raw risk ranking? (tap and select one risk score)

  • What current and existing controls are in place to manage hazards risks for entry and work in this space? (tap and select existing controls)

  • Are there any other current and existing controls in place?

  • What is the revised risk ranking with the current and existing controls maintained? (tap and select one risk score)

  • What are the recommended further actions, including medium and/or longer-term controls to either eliminate or further minimise risks associated with entry and/or work in this space?

  • What is the predicted revised risk ranking assuming these further actions including higher order controls are implemented? (tap and select one risk score)

  • Have Corrective Actions been raised on SafeGuard to allocate and track agreed safety improvements?

  • List any Corrective Action ID numbers here

  • It is recommended that any and all relevant corrective actions be raised in SafeGuard as soon as possible.

  • Bin Base - BB
  • Storage Code

  • Location (be detailed describe in words where the space is).

  • Image of Space being assessed (both before and after assessment and marking). Please include a photo of the space and each sign prior to assessment and then post assessment once it has been either re-marked or removed.

  • Criteria for classification of a Confined Space (ref' AS 2865__2009)
  • Is this space enclosed or partially enclosed?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • Is this space not designed or intended to be occupied by a person?

  • Is or is intended to be at normal atmospheric pressure while any person is in the space?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks which may need to have additional controls put in place before entering the space.

  • Is there a risk of one or more of the following? An oxygen concentration outside the safe oxygen range, A concentration of airborne contaminants that may cause impairment, loss of consciousness or asphyxiation, A concentration of airborne contaminants that may cause injury from fire or explosion, Engulfment in a stored free flowing solid or a rising level of liquid that may cause suffocation or drowning.

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks which may need to have additional controls put in place before entering the space.

  • Is this space in Victoria?

  • Does the space have a restricted entry or exit?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks which may need to have additional controls put in place before entering the space.

  • This Space meets all the criteria for a Confined Space and must be risk assessed and controls implemented before entry to the space can be effected.

  • This Space meets all the criteria for a Confined Space and must be risk assessed and controls implemented before entry to the space can be effected.

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks which may need to have additional controls put in place before entering the space.

Risk Assessment

  • What are the inherent hazards and risks of this space? (tap for drop down menu)

  • Are there other inherent hazards and risks of this space?

  • Review any previous documented risk assessments for this space. A revised risk assessment must now be completed that considers the level of safety management from current existing controls, as well as the predicted enhanced level of safety that could be achieved upon implementation of further higher order controls. The ranking score and risk mitigation measures should be determined through application of the GrainCorp Risk Assessment Matrix and Hierarchy of Controls.

    C1ACCFA3-91F2-41E2-8BC7-E7E0CE02ADBA.jpg
  • What is the Raw risk ranking? (tap and select one risk score)

  • What current and existing controls are in place to manage hazards risks for entry and work in this space? (tap and select existing controls)

  • Are there any other current and existing controls in place?

  • What is the revised risk ranking with the current and existing controls maintained? (tap and select one risk score)

  • What are the recommended further actions, including medium and/or longer-term controls to either eliminate or further minimise risks associated with entry and/or work in this space?

  • What is the predicted revised risk ranking assuming these further actions including higher order controls are implemented? (tap and select one risk score)

  • Have Corrective Actions been raised on SafeGuard to allocate and track agreed safety improvements?

  • Boot Pit - BP

  • Boot Pit - BP
  • Storage Code

  • Location (be detailed describe in words where the space is).

  • Image of Space being assessed (both before and after assessment and marking). Please include a photo of the space and each sign prior to assessment and then post assessment once it has been either re-marked or removed.

Criteria for classification of a Confined Space (ref' AS 2865__2009)

  • Is this space enclosed or partially enclosed?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • Is this space not designed or intended to be occupied by a person?

  • Is or is intended to be at normal atmospheric pressure while any person is in the space?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • Is there a risk of one or more of the following? An oxygen concentration outside the safe oxygen range, A concentration of airborne contaminants that may cause impairment, loss of consciousness or asphyxiation, A concentration of airborne contaminants that may cause injury from fire or explosion, Engulfment in a stored free flowing solid or a rising level of liquid that may cause suffocation or drowning.

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • Is this space in Victoria?

  • This Space meets all the criteria for a Confined Space and must be risk assessed and controls implemented before entry to the space can be effected.

  • Does the space have a restricted entry or exit?

  • This Space meets all the criteria for a Confined Space and must be risk assessed and controls implemented before entry to the space can be effected.

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

Risk Assessment

  • What are the inherent hazards and risks of this space? (tap for drop down menu)

  • Are there other inherent hazards and risks of this space?

  • Review any previous documented risk assessments for this space. A revised risk assessment must now be completed that considers the level of safety management from current existing controls, as well as the predicted enhanced level of safety that could be achieved upon implementation of further higher order controls. The ranking score and risk mitigation measures should be determined through application of the GrainCorp Risk Assessment Matrix and Hierarchy of Controls.

    C1ACCFA3-91F2-41E2-8BC7-E7E0CE02ADBA.jpg
  • What is the Raw risk ranking? (tap and select one risk score)

  • What current and existing controls are in place to manage hazards risks for entry and work in this space? (tap and select existing controls)

  • Are there any other current and existing controls in place?

  • What is the revised risk ranking with the current and existing controls maintained? (tap and select one risk score)

  • What are the recommended further actions, including medium and/or longer-term controls to either eliminate or further minimise risks associated with entry and/or work in this space?

  • What is the predicted revised risk ranking assuming these further actions including higher order controls are implemented? (tap and select one risk score)

  • Have Corrective Actions been raised on SafeGuard to allocate and track agreed safety improvements?

  • Receival Hopper - RH

  • Receival Hopper - RH
  • Storage Code

  • Location (be detailed describe in words where the space is).

  • Image of Space being assessed (both before and after assessment and marking). Please include a photo of the space and each sign prior to assessment and then post assessment once it has been either re-marked or removed.

Criteria for classification of a Confined Space (ref' AS 2865__2009)

  • Is this space enclosed or partially enclosed?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • Is this space not designed or intended to be occupied by a person?

  • Is or is intended to be at normal atmospheric pressure while any person is in the space?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks which may need to have additional controls put in place before entering the space.

  • Is there a risk of one or more of the following? An oxygen concentration outside the safe oxygen range, A concentration of airborne contaminants that may cause impairment, loss of consciousness or asphyxiation, A concentration of airborne contaminants that may cause injury from fire or explosion, Engulfment in a stored free flowing solid or a rising level of liquid that may cause suffocation or drowning.

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • Is this space in Victoria?

  • This Space meets all the criteria for a Confined Space and must be risk assessed and controls implemented before entry to the space can be effected.

  • Does the space have a restricted entry or exit?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • This Space meets all the criteria for a Confined Space and must be risk assessed and controls implemented before entry to the space can be effected.

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks which may need to have additional controls put in place before entering the space.

Risk Assessment

  • What are the inherent hazards and risks of this space? (tap for drop down menu)

  • Are there other inherent hazards and risks of this space?

  • Review any previous documented risk assessments for this space. A revised risk assessment must now be completed that considers the level of safety management from current existing controls, as well as the predicted enhanced level of safety that could be achieved upon implementation of further higher order controls. The ranking score and risk mitigation measures should be determined through application of the GrainCorp Risk Assessment Matrix and Hierarchy of Controls.

    C1ACCFA3-91F2-41E2-8BC7-E7E0CE02ADBA.jpg
  • What is the Raw risk ranking? (tap and select one risk score)

  • What current and existing controls are in place to manage hazards risks for entry and work in this space? (tap and select existing controls)

  • Are there any other current and existing controls in place?

  • What is the revised risk ranking with the current and existing controls maintained? (tap and select one risk score)

  • What are the recommended further actions, including medium and/or longer-term controls to either eliminate or further minimise risks associated with entry and/or work in this space?

  • What is the predicted revised risk ranking assuming these further actions including higher order controls are implemented? (tap and select one risk score)

  • Have Corrective Actions been raised on SafeGuard to allocate and track agreed safety improvements?

  • Garner Bin - GB

  • Garner Bin - GB
  • Storage Code

  • Location (be detailed describe in words where the space is).

  • Image of Space being assessed (both before and after assessment and marking). Please include a photo of the space and each sign prior to assessment and then post assessment once it has been either re-marked or removed.

Criteria for classification of a Confined Space (ref' AS 2865__2009)

  • Is this space enclosed or partially enclosed?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • Is this space not designed or intended to be occupied by a person?

  • Is or is intended to be at normal atmospheric pressure while any person is in the space?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • Is there a risk of one or more of the following? An oxygen concentration outside the safe oxygen range, A concentration of airborne contaminants that may cause impairment, loss of consciousness or asphyxiation, A concentration of airborne contaminants that may cause injury from fire or explosion, Engulfment in a stored free flowing solid or a rising level of liquid that may cause suffocation or drowning.

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • Is this space in Victoria?

  • This Space meets all the criteria for a Confined Space and must be risk assessed and controls implemented before entry to the space can be effected.

  • Does the space have a restricted entry or exit?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • This Space meets all the criteria for a Confined Space and must be risk assessed and controls implemented before entry to the space can be effected.

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

Risk Assessment

  • What are the inherent hazards and risks of this space? (tap for drop down menu)

  • Are there other inherent hazards and risks of this space?

  • Review any previous documented risk assessments for this space. A revised risk assessment must now be completed that considers the level of safety management from current existing controls, as well as the predicted enhanced level of safety that could be achieved upon implementation of further higher order controls. The ranking score and risk mitigation measures should be determined through application of the GrainCorp Risk Assessment Matrix and Hierarchy of Controls.

    C1ACCFA3-91F2-41E2-8BC7-E7E0CE02ADBA.jpg
  • What is the Raw risk ranking? (tap and select one risk score)

  • What current and existing controls are in place to manage hazards risks for entry and work in this space? (tap and select existing controls)

  • Are there any other current and existing controls in place?

  • What is the revised risk ranking with the current and existing controls maintained? (tap and select one risk score)

  • What are the recommended further actions, including medium and/or longer-term controls to either eliminate or further minimise risks associated with entry and/or work in this space?

  • What is the predicted revised risk ranking assuming these further actions including higher order controls are implemented? (tap and select one risk score)

  • Have Corrective Actions been raised on SafeGuard to allocate and track agreed safety improvements?

  • Under Silo - US

  • Under Silo - US
  • Storage Code

  • Location (be detailed describe in words where the space is).

  • Image of Space being assessed (both before and after assessment and marking). Please include a photo of the space and each sign prior to assessment and then post assessment once it has been either re-marked or removed.

Criteria for classification of a Confined Space (ref' AS 2865__2009)

  • Is this space enclosed or partially enclosed?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • Is this space not designed or intended to be occupied by a person?

  • Is or is intended to be at normal atmospheric pressure while any person is in the space?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • Is there a risk of one or more of the following? An oxygen concentration outside the safe oxygen range, A concentration of airborne contaminants that may cause impairment, loss of consciousness or asphyxiation, A concentration of airborne contaminants that may cause injury from fire or explosion, Engulfment in a stored free flowing solid or a rising level of liquid that may cause suffocation or drowning?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • Is this space in Victoria?

  • This Space meets all the criteria for a Confined Space and must be risk assessed and controls implemented before entry to the space can be effected.

  • Does the space have a restricted entry or exit?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • This Space meets all the criteria for a Confined Space and must be risk assessed and controls implemented before entry to the space can be effected.

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

Risk Assessment

  • What are the inherent hazards and risks of this space? (tap for drop down menu)

  • Are there other inherent hazards and risks of this space?

  • Review any previous documented risk assessments for this space. A revised risk assessment must now be completed that considers the level of safety management from current existing controls, as well as the predicted enhanced level of safety that could be achieved upon implementation of further higher order controls. The ranking score and risk mitigation measures should be determined through application of the GrainCorp Risk Assessment Matrix and Hierarchy of Controls.

    C1ACCFA3-91F2-41E2-8BC7-E7E0CE02ADBA.jpg
  • What is the Raw risk ranking? (tap and select one risk score)

  • What current and existing controls are in place to manage hazards risks for entry and work in this space? (tap and select existing controls)

  • Are there any other current and existing controls in place?

  • What is the revised risk ranking with the current and existing controls maintained? (tap and select one risk score)

  • What are the recommended further actions, including medium and/or longer-term controls to either eliminate or further minimise risks associated with entry and/or work in this space?

  • What is the predicted revised risk ranking assuming these further actions including higher order controls are implemented? (tap and select one risk score)

  • Have Corrective Actions been raised on SafeGuard to allocate and track agreed safety improvements?

  • Tunnel - TU
  • Storage Code

  • Location (be detailed describe in words where the space is).

  • Image of Space being assessed (both before and after assessment and marking). Please include a photo of the space and each sign prior to assessment and then post assessment once it has been either re-marked or removed.

Criteria for classification of a Confined Space (ref' AS 2865__2009)

  • Is this space enclosed or partially enclosed?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • Is this space not designed or intended to be occupied by a person?

  • Is or is intended to be at normal atmospheric pressure while any person is in the space?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • Is there a risk of one or more of the following? An oxygen concentration outside the safe oxygen range, A concentration of airborne contaminants that may cause impairment, loss of consciousness or asphyxiation, A concentration of airborne contaminants that may cause injury from fire or explosion, Engulfment in a stored free flowing solid or a rising level of liquid that may cause suffocation or drowning?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • Is this space in Victoria?

  • This Space meets all the criteria for a Confined Space and must be risk assessed and controls implemented before entry to the space can be effected.

  • Does the space have a restricted entry or exit?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • This Space meets all the criteria for a Confined Space and must be risk assessed and controls implemented before entry to the space can be effected.

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

Risk Assessment

  • What are the inherent hazards and risks of this space? (tap for drop down menu)

  • Are there other inherent hazards and risks of this space?

  • Review any previous documented risk assessments for this space. A revised risk assessment must now be completed that considers the level of safety management from current existing controls, as well as the predicted enhanced level of safety that could be achieved upon implementation of further higher order controls. The ranking score and risk mitigation measures should be determined through application of the GrainCorp Risk Assessment Matrix and Hierarchy of Controls.

    C1ACCFA3-91F2-41E2-8BC7-E7E0CE02ADBA.jpg
  • What is the Raw risk ranking? (tap and select one risk score)

  • What current and existing controls are in place to manage hazards risks for entry and work in this space? (tap and select existing controls)

  • Are there any other current and existing controls in place?

  • What is the revised risk ranking with the current and existing controls maintained? (tap and select one risk score)

  • What are the recommended further actions, including medium and/or longer-term controls to either eliminate or further minimise risks associated with entry and/or work in this space?

  • What is the predicted revised risk ranking assuming these further actions including higher order controls are implemented? (tap and select one risk score)

  • Have Corrective Actions been raised on SafeGuard to allocate and track agreed safety improvements?

  • Septic Tank - ST
  • Storage Code

  • Location (be detailed describe in words where the space is).

  • Image of Space being assessed (both before and after assessment and marking). Please include a photo of the space and each sign prior to assessment and then post assessment once it has been either re-marked or removed.

Criteria for classification of a Confined Space (ref' AS 2865__2009)

  • Is this space enclosed or partially enclosed?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • Is this space not designed or intended to be occupied by a person?

  • Is or is intended to be at normal atmospheric pressure while any person is in the space?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • Is there a risk of one or more of the following? An oxygen concentration outside the safe oxygen range, A concentration of airborne contaminants that may cause impairment, loss of consciousness or asphyxiation, A concentration of airborne contaminants that may cause injury from fire or explosion, Engulfment in a stored free flowing solid or a rising level of liquid that may cause suffocation or drowning?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • Is this Space in Victoria?

  • This Space meets all the criteria for a Confined Space and must be risk assessed and controls implemented before entry to the space can be effected.

  • Does the space have a restricted entry or exit?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • This Space meets all the criteria for a Confined Space and must be risk assessed and controls implemented before entry to the space can be effected.

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

Risk Assessment

  • What are the inherent hazards and risks of this space? (tap for drop down menu)

  • Are there other inherent hazards and risks of this space?

  • Review any previous documented risk assessments for this space. A revised risk assessment must now be completed that considers the level of safety management from current existing controls, as well as the predicted enhanced level of safety that could be achieved upon implementation of further higher order controls. The ranking score and risk mitigation measures should be determined through application of the GrainCorp Risk Assessment Matrix and Hierarchy of Controls.

    C1ACCFA3-91F2-41E2-8BC7-E7E0CE02ADBA.jpg
  • What is the Raw risk ranking? (tap and select one risk score)

  • What current and existing controls are in place to manage hazards risks for entry and work in this space? (tap and select existing controls)

  • Are there any other current and existing controls in place?

  • What is the revised risk ranking with the current and existing controls maintained? (tap and select one risk score)

  • What are the recommended further actions, including medium and/or longer-term controls to either eliminate or further minimise risks associated with entry and/or work in this space?

  • What is the predicted revised risk ranking assuming these further actions including higher order controls are implemented? (tap and select one risk score)

  • Have Corrective Actions been raised on SafeGuard to allocate and track agreed safety improvements?

  • Other (inc. Dust System) - OT
  • Storage Code

  • Location (be detailed describe in words where the space is).

  • Image of Space being assessed (both before and after assessment and marking). Please include a photo of the space and each sign prior to assessment and then post assessment once it has been either re-marked or removed.

Criteria for classification of a Confined Space (ref' AS 2865__2009)

  • Is this space enclosed or partially enclosed?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • Is this space not designed or intended to be occupied by a person?

  • Is or is intended to be at normal atmospheric pressure while any person is in the space?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • Is there a risk of one or more of the following? An oxygen concentration outside the safe oxygen range, A concentration of airborne contaminants that may cause impairment, loss of consciousness or asphyxiation, A concentration of airborne contaminants that may cause injury from fire or explosion, Engulfment in a stored free flowing solid or a rising level of liquid that may cause suffocation or drowning?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • Is this space in Victoria?

  • This Space meets all the criteria for a Confined Space and must be risk assessed and controls implemented before entry to the space can be effected.

  • Does the space have a restricted entry or exit?

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

  • This Space meets all the criteria for a Confined Space and must be risk assessed and controls implemented before entry to the space can be effected.

  • This space does not meet the criteria of a 'Confined Space', however may still present a work area with some inherent hazards and risks. Please continue.

Risk Assessment

  • What are the inherent hazards and risks of this space? (tap for drop down menu)

  • Are there other inherent hazards and risks of this space?

  • Review any previous documented risk assessments for this space. A revised risk assessment must now be completed that considers the level of safety management from current existing controls, as well as the predicted enhanced level of safety that could be achieved upon implementation of further higher order controls. The ranking score and risk mitigation measures should be determined through application of the GrainCorp Risk Assessment Matrix and Hierarchy of Controls.

    C1ACCFA3-91F2-41E2-8BC7-E7E0CE02ADBA.jpg
  • What is the Raw risk ranking? (tap and select one risk score)

  • What current and existing controls are in place to manage hazards risks for entry and work in this space? (tap and select existing controls)

  • Are there any other current and existing controls in place?

  • What is the revised risk ranking with the current and existing controls maintained? (tap and select one risk score)

  • What are the recommended further actions, including medium and/or longer-term controls to either eliminate or further minimise risks associated with entry and/or work in this space?

  • What is the predicted revised risk ranking assuming these further actions including higher order controls are implemented? (tap and select one risk score)

  • Have Corrective Actions been raised on SafeGuard to allocate and track agreed safety improvements?

  • Further comments/ notes:

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.