Title Page
-
Company
-
Client name
-
Location
-
Prepared by
-
Date of Inspection
-
Site Supervisor
-
Personnel on site
-
Works being completed on site
Crane Focus Inspection
-
"Does the crane driver hold the relevant high risk work licence?
-
"Is the operators manual in the crane? Has the equipment prestart book been completed?
-
"Are service records and 12 month inspection/maintenance reports available?
-
"Is the crane fitted with a load indicator and is it operational?
-
"Is the crane fitted with a rated capacity limiter and is it operational?
-
"Are dead-man levers and foot pedals returning to the neutral position automatically upon release by the operator?
-
"Are load charts legible, kept with the crane ?
-
"Are hydraulic rams, hoses, tyres and/or tracks and connections in good order?
-
Is the work area congested ?
-
"Are outriggers clear of excavations, soft or filled ground? Are outriggers fully extended? Note: If outriggers are not fully extended, the reduced safe operating radius must recorded in the SWMS.
-
"Are timbers under outrigger pads secure eg: solid blocked (pig sty formation)?
-
"Where bog mats are used, has certification of the ground bearing capacity been obtained from a geo-technical engineer?
-
"Is there an exclusion zone erected around crane slew radius?
-
"Are precautions in place regarding suspended loads passing over workers?
-
"Is the load a Critical Lift? – More than one crane is utilised. Special lifting equipment or non-standard crane configuration used. Gross load greater than 50 tonnes. Load capacity greater than 85% of chart capacity.
-
"Does the crane have WorkSafe registration (Cranes > than 10 tonnes)?
-
"Are clear communication protocols in place to control lifts (eg: radios clear without interference, whistles can be heard, clear line of sight when signalling)?
-
"Is there the proper number of Tag lines used on all loads (made of 16mm natural fiber rope)?
-
"If crane is operating in close proximity to overhead powerlines, has written permission from the local power company been obtained?
-
Add any additional relevant photos
-
Further Notes/Commentary
Fall Prevention - Focus Inspection
-
Has a risk assessment been conducted prior to undertaking work at heights?
-
Has barricading been installed to eliminate the fall potential?
-
Are barricades erected at least 1.8 meters away from the fall hazard?
-
Does the barricade have a top and middle rail with a bottom kick board?
-
Are hole covers secured and properly labelled?
-
Where employees are required to Work at heights are they trained?
-
Is a SWMS for the task in place, and have all personnel signed and been instructed on the SWMS?
-
Are employees aware of the correct anchorage points?
-
Is the current quarterly inspection tag or colour displayed?
-
Is any defective fall protection equipment properly tagged out of service?
-
Is there a quarantine area for out of service fall arrest equipment?
-
Are personal fall arrest system components connected above the D ring to limit free fall distance?
-
Are employees working on scaffolding, where fall protection is required, using personal fall arrest systems 100% of the time?
-
Are all anchor points compliant with an annual inspection tag installed and inspected by a qualified person?
-
Are employees connected to the required anchorage points in aerial lifting devices (EWP)?
-
Are employees carrying materials able to maintain 3 points of contact, e.g. using tool belts?
-
Are employees using tool lanyards, as required?
-
When using ladders, do employees maintain 3 points of contact?
-
Is appropriate signage on ladders/platforms indicating fall protection requirements?
-
Add any additional relevant photos
-
Further Notes/Commentary
Workshop - Focus Inspection
-
Is the workshop area tidy and free from trip hazards?
-
Are the walkways unobstructed?
-
Are sharp objects covered / protected?
-
Are tools and equipment stored correctly when not in use?
-
Are materials stored correctly when not in use?
-
Is there adequate lighting for the work being carried out?
-
Are fire extinguishers easily identifiable, unobstructed and within current test date?
-
Are there RCD’s on all electrical equipment?
-
Are the tools and equipment being used correct for the task being undertaken?
-
Is guarding fitted to all rotating equipment?
-
Are sparks contained and welding screens used during cutting/burning and welding activities?
-
Is the required PPE available?
-
Is the PPE being used correct for task being undertaken?
-
Is dust mitigation implemented in the area?
-
Is there the appropriate bunding of the hazardous materials stored in the workshop?
-
Are the appropriate spill kits available and fully stocked?
-
Are waste segregation measures in place & containers correctly labelled?
-
Is there regular disposal of waste?
-
Add any additional relevant photos
-
Further Notes/Commentary
General
-
Any further comments or recommendations arising from this inspection?
-
Add any additional relevant photos
-
Have all required corrective actions been added as Actions to this inspection?
-
Please add any corrective actions to the appropriate questions above before completing this report
Sign off
-
Name & Signature of Inspector
-
Name & Signature of Site Supervisor / Foreman