Title Page
-
Customer Name
-
Mobile:
-
Email:
-
Address:
-
Property Age (In years):
-
Property Type:
- CHS
- Individual House/Bungalow
- Flat
- Commercial
- Industrial
- Educational
-
Floors:
-
Previous Structural audit done
-
Previous Repair work done
-
Inspection Date and Time:
-
Inspected By:
Site Details
-
Impacted Areas/Rooms
Impacted Area
-
Negative side Description
-
Negative side photographs
-
Positive side Description
-
Positive side photographs
Checklists
Inspection Checklists
-
Checklist:
- WC
- Balcony
- Terrace
- External wall
Negative Side Inputs for WC
-
Condition of leakage at adjacent walls
- No leakage
- Dampness
- Seepage/Mild leakage (waterproofing)
- Live Leakage (Plumbing)
-
Condition of leakage below balcony
- No leakage
- Dampness
- Seepage/Mild leakage (waterproofing)
- Live Leakage (Plumbing)
-
Leakage during:
-
Leakage due to concealed plumbing
-
Leakage due to damage in Nahani trap/Brickbat coba under tile flooring
Positive Side Inputs For WC
-
Gaps/Blackish dirt Observed in tile joints
-
Gaps around Nahani Trap Joints
-
Tiles Broken/Loosed anywhere
-
Loose Plumbing joints/rust around joints and edges (Flush Tank/shower/angle cock/bibcock, washbasin, etc)
-
Type of tile
Negative Side Inputs for Balcony
-
Condition of leakage at adjacent wall
- No leakage
- Dampness
- Seepage/Mild leakage (waterproofing)
- Live Leakage (Plumbing)
-
Condition of leakage below floor of the balcony
- No leakage
- Dampness
- Seepage/Mild leakage (waterproofing)
- Live Leakage (Plumbing)
-
Leakage during:
-
Leakage due to concealed plumbing
-
Exposed Construction joint: Linear crack from outside/spalling of plaster
-
Leakage due to damage in Nahani traps/Brick Bat coba under tile flooring
Positive Side Inputs for Balcony
-
Gaps/Blackish Dirt observed in Tile Joints
-
Gaps around Nahani Trap Joints
-
Tiles Broken/Loosed Anywhere
-
Mechanical decoration, plants, pots etc observed in balcony
-
Loose plumbing joints/rust around joints and edges
-
Type of tile
Negative Side Inputs For External Wall
-
Condition of leakage at interior side
- No leakage
- Dampness
- Seepage/Mild leakage (waterproofing)
- Live Leakage (Plumbing)
-
Leakage during:
-
Leakage due to concealed plumbing
-
Internal WC/Bath/Balcony leakage observed
Positive Side Inputs for External Wall
-
Existing type of paint and manufacturer
- No Paint
- White wash
- Cement Paint
- Semi acrylic emulsions
- Acrylic Emulsion
- Premium waterproof acrylic emulsion
- Textured Paint
- Not sure
Stuctural Condition of RCC Members
-
Condition of cracks observed on RCC Column and Beam
-
Condition of rust marks observed in RCC Beam and Column
-
Condition of corrosion/spalling of concrete/exposed reinforcement observed in column/beams/roof slab ceiling
-
Expansion joints condition if any
Condition of External wall
-
Are there any major or minor cracks observed over external surface?
-
Are the sealants applied on the window frame joints intact?
-
Condition of wall mounted AC Frames, holes, drain pipes over the wall.
-
Are the external plumbing pipes cracked and leaked? If yes its condition.
-
Are the openings around the pipes in external wall properly grouted? If not its condition.
-
Condition of any vegetation growth, dish antennas fixed on parapet wall observed?
Condition of Adhesion of old paint
-
Chalking and flaking in paint film.
-
Algae fungus and Moss observed on external wall?
-
Bird droppings condition observed on external wall and Chajja
-
Condition of corrosion on metal rods and MS window grills
Substrate condition of Plaster
-
Patchwork plaster required? if yes its condition?
-
Entire replaster required? if yes its condition?
-
Condition of separation cracks observed at beam-column junction
-
Condition of leakage observed from overhead water tank
-
Loose plaster/hollow sound on external surfaces?if observed, its condition?
-
Negative Side Inputs for Terrace
-
Condition of leakage in ceiling below terrace slab
- No leakage
- Dampness
- Seepage/Mild leakage (waterproofing)
- Live Leakage (Plumbing)
-
Condition of leakage near ceiling and wall corner junction
- No leakage
- Dampness
- Seepage/Mild leakage (waterproofing)
- Live Leakage (Plumbing)
-
Season of leakage
-
Leakage due to concealed Plumbing
Positive Side inputs for terrace
-
Existing waterproofing system
- BB Coba
- China Mosaic
- Concrete Screed
- Liquid applied chemical coating
- Cement sand low grade mortar
- Naked slab
Structural Condition Assessment of Terrace
-
Condition of existing waterproofing system
-
Condition of debris on roof
-
Condition of adequate slope provided (1:100 or 1:80)
-
Adequate no. of rain water outlets provided
-
Condition of waterponding , water getting accumulated at one place or near drain outlet point
-
Condition of finishing around upstands of waterpipelines/solar water heater/solar PV or any other instruments etc
-
Condition of leakage from supply lines/rainwater outlets
-
Surface cracks condition observed on terrace/broken tiles
-
Hollow surface condition identified and checked by nylon hammer
-
Condition of surface finishing for chemical/membrane application
-
Condition of any cracks/absence of proper watta/fillet at junction of roof terrace and parapet wall.
-
Expansion joint condition if any
-
Growth of vegetation
-
Condition of parapet wall Top (specify: Naked/Tiled)
-
Condition of damage due to dish antenna, manual drilling/any other damage on parapet wall
-
Terrace staircase tops/Topi, exterior wall and threshold condition
-
Condition of any concealed plumbing connections found at terrace