Title Page
Client and System Infomation
-
Customer Name
-
Address
-
SGS Number
-
Date of Install
-
System Type (Make/Model)
-
Alarm System Grade :
-
Alarm system Grading - All devices must be the same grade or higher, and match the grade on the specification
Readings Sheet
Intruder System Readings and Testing sheet
Circuit Details and Tests
-
Add all circuits that have been installed on the system and complete all relevant fields
Circuit
Circuit details :
-
Circuit Type
-
Circuit number
-
Location
-
Areas
- A -1
- B - 2
- C - 3
- D - 4
- E - 5
- F - 6
- G - 7
- H - 8
- I - 9
- J - 10
- K - 11
- L - 12
- M - 13
- N - 14
- O - 15
- P - 16
-
Circuit Resistance in Ohms
-
Tamper Circuit Resistance in Ohms
-
Voltage in Vdc
-
Masking Enabled : ( If grade 3 this has to be enabled )
-
Circuit number
-
Location
-
Areas
- A -1
- B - 2
- C - 3
- D - 4
- E - 5
- F - 6
- G - 7
- H - 8
- I - 9
- J - 10
- K - 11
- L - 12
- M - 13
- N - 14
- O - 15
- P - 16
-
Wireless Signal Strength
-
Wireless Device Battery type
Control Panel Information and Tests
-
Panel Location
-
Battery current ( mains supply disconnected): mA
-
Battery Current (In Alarm): mA
-
Battery Calculation ( battery current ( mains supply disconnected) x15 + Battery Current (In Alarm) )
-
Battery Capacity Fitted (Ahr) :
-
Battery charging voltage : Vdc
-
Set by
-
Exit time ( <40s)
Entry Time not to exceed (40s)
App setting period not less than (30s) if app enabled
Bell Delay <2s
Bell Duration <15Min -
Exit Time ( in seconds )
-
Entry Time ( In seconds )
-
P/A
-
Bell Delay: in seconds
-
Bell Duration ( In Minutes ) Max 15 - mins
-
Reset
- Engineer
- Customer
- ARC
- Code
-
Line Fault Monitor
Power supplies and expanders
-
Add Smart or Standard Power supplies in this section
PSU
PSU Details
-
PSU Location
-
Expander Address ( If part of Data Line) :
-
PSU Battery charging voltage
-
PSU Battery current (mains Disconnected)
-
PSU Battery Calculation ( battery current ( mains supply disconnected) x15 + Battery Current (In Alarm) )
-
Battery Capacity Fitted (Ahr) :
-
Following are for Stand-Alone PSU's)
-
Mains Fail Circuit wired to Controls : record circuit number - only applies for stand alone PSU's not Smart PSUS
-
Battery Fail Circuit wired to Controls : record circuit number
-
Tamper Circuit wired to Controls : record circuit number
Standard/Wireless Expander's
-
System Expanders ( Standard )
Expander :
Expander 1 details
-
Location
-
Expander address :
-
Back Tamper fitted ( Grade 3 + wireless mandatory requirement )
-
Type ( wired or Wireless )
Keypads and Prox Readers
-
Keypads installed
Keypad :
Keypad/Reader 1 Details
-
Keypad Location
-
Keypad Address :
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
-
Keypad Group
- A -1
- B - 2
- C - 3
- D - 4
- E - 5
- F - 6
- G - 7
- H - 8
- I - 9
- J - 10
- K - 11
- L - 12
- M - 13
- N - 14
- O - 15
- P - 16
-
Keypad Type (make/Model)
-
Back Tamper Enabled ( grade 3 + Wireless mandatory requirement )
3rd Party Interface's
-
Fire Alarm Relay Installed
-
Provide Details ie location
-
Lighting interface installed
-
Provide details and locations of interface's
-
CCTV Link
-
Provide details
-
Smoak Cloak/Smartwater Fitted
-
Smoke cloak Trigger Connection details :
Smoke cloak Triggers :
-
Output number :
-
Output description :
-
Output polarity :
-
Isolation/Test Key-switch Fitted
-
Customer Signature
-
Date and Time
Inspection compliance Checklist
General Compliance Checks
-
Check that the Requirements of BS4737/PD6662 and all other relevant requirements
-
Cabling has been carried out in accordance with 18th edition wiring regulations (BS7671) how cables are support in the event of a fire- ie metal clips/ties used to support cable along entire route
-
Check all detection and devices match the grade on the specification and are of the same grade or higher
-
Check all detection circuits are clearly texted in the keypad and match as fitted Specification
-
Mains connected to an Unswitched Spur manditory on grade 3 and above If on Plug top make note on handover checklist and fit a captive plug cover ( grade 2 only )
- Yes - Unswitched Fuse spur Supplied
- Supply by Plug - Captive Plug cover fitted
-
Check Supply fuses to the alarm installation have the correct rating
-
Check batteries are clearly marked with date of installtion
-
Remove mains supply and check the battery supply voltage of all equipment is within the specified limits of the manufacturers equipment and the system operates normally
-
Check the operation of the audible alarm on system activation and when the hold off voltage is removed from an SAB Devices
-
Check remote signalling apparatus is signalling correctly and the correct test signals have been sent and received by the monitoring station
-
For police calling systems confirm the keypad has been locked out on entry ( ie code can not unset only Fobs)
-
Check ATS system/line fault correctly wired to control panel so as to indicate failure to customer
-
Check the Engineer and Code Reset facilities are set up correctly as per the Grade of system
-
Walk test the system - check tamper circuits and alarm circuits
-
Circuits tested
-
Tampers Tested ( inc Back tampers for wireless/Grade 3/4)
-
Masking tested
-
Check the Exit/Entry route Delay ( if used and correct settings recorded ( not to exceed 40s)
-
Check the final exit tones can be heard from outside the final exit door
-
Set the system and confirm the correct alarm conditions are correctly indicated
-
Check that all suplus material and equipment is cleared from site and that the customers premises have been left tidy
-
take picture of final work area
-
Check that the User log book and operation instructions are left on site and that all documentation is correct
-
Have you informed the customer that any documents left on site may contain personal information about there security and should be stores securely, as per ISO 27001 & GDPR Policy
-
Has the Contract number sticker been installed
Extra Requirements for wireless and Grade 3
-
Additional checks for Grade 2 wireless & Grade 3
Grade 3 compliance
-
Back Tampers enabled on all devices inc keypads/Expanders/Warning devices etc<br>
-
Back Tampers enabled on all detection devices<br>
-
External Sounder has Fault Reporting Enabled (loss of remote power/Tamper)<br>
-
Sounder bell wire trigger monitoring <br>
-
Contacts have substitution enabled<br>
-
Masking Enabled on all Detectors<br>
-
LEDs Disabled other than when in Walktest<br>
-
User and Engineer codes 5 or more digits ( 100,000) or greater combination<br>
-
Mains Fail transmitted to ARC seperately to General fault or 24hr battery backup<br>
-
Tamper set to Engineer Reset<br>
-
Tamper Transmitted<br>
-
General Fault Transmitted<br>
Wireless Additional Checks
-
Back Tampers enabled on all Controls IE: keypads/Expanders/Sounders<br>
-
Back Tampers enabled on all detection devices<br>
-
Setting period not less than 30s if set remotely (app/fob) and that an audiable sound can be heard throughout the building.<br>
Handover
Amendments to specification
-
Check that the Installation is in strict accordance with the agreed Design Specification and is to acceptable workmanship - alterations to the specification have to be documented and signed for by the customer
add detail for each alteration
-
Details of Changes to specification
Completion certificate
-
Keyholders/User's trained
User trained
-
Add signature
Final sign off
-
Does Customer have App access enabled
-
Customer advised <br>1- if using app that they need to consult the manufacturers website regularly to ensure compatibility is maintained and that it is there responsibility to keep the app and there viewing device up to date with the latest firmware as per the manufactures instructions - The Company do not accept any responsibility for 3rd Party application and issues arising from the use thereof<br>2- “IMPORTANT If using a remote device to remotely set/unset your intruder alarm system, your attention is drawn to the fact that whenever a premises is unattended but its intruder alarm system(s) is (are) not fully set, any related insurance cover might be inoperative. For advice on this matter, it is recommended that you consult your insurer(s).”
-
FOB's/Remote setting devices Supplied
-
Number of Fobs supplied and Handed over
-
Panic Buttons Fitted
-
Number of reset keys handed over
-
Please tick to confirm you are happy with you Alarm Company having unlimited access to the system engineer menu's as in BS EN 50131-1 (cl 8.3.1)
-
I Sign to confirm that :
I am happy to accept the installed system and that I have been given a demonstration and am happy with how the system works.
I agree that the site has been left clean
The system has been left full operational. -
Customer/Customer's representative's Signature
-
Engineer Signature
-
Date of handover
-
Take Picture of Keypad to prove alarm left in day mode with no faults present