Title Page

  • Site conducted

  • DATE AUDIT CONDUCTED

  • FOR LOCAL #

  • WHAT TYPE OF AUDIT CONDUCTED

  • AUDIOR'S NAME

  • Location

ACREDITED TESTING FACILITY STAFF

  • PERSON INTERVIEWED

  • TRAINING COORDINATOR:

  • PHONE #:

  • EMAIL ADDRESS

I. STAFF FILES

  • IS THERE A FILE LABLED FOR THE FACILITY REPRESENITIVE?

  • DOES THE FACILITY REPRESENTATIVE HAVE A MINIMUM OF FIVE YEARS OF TECHNICAL EXPERIENCE IN INSPECTION AND WELD TESTING?

  • IS THERE A FILE LABELED FOR THE QUALITY ASSURANCE MANAGER?

  • THE FILE MUST CONTAIN THE FOLLOWING.

  • IS THERE A FILE LABELED FOR EACH TEST SUPERVISOR / QUALIFIER?

  • THE FILE MUST CONTAIN THE FOLLOWING

  • IS THERE A FILE LABELED FOR EACH WELDING INSTRUCTOR?

  • THE FILES MUST INCLUDE THE FOLLOWING.

  • HOW MANY WELDING INSTRUCTORS ARE EMPLOYED?

  • LIST NAMES AND MEMBER NUMBERS (CWI CERTIFICATION NUMBER AND WPQ1 ENDORCMENT IF APPLICABLE)

  • DOES THE ACCREDITED TEST FACILITY EMPLOY NDE PERSONNEL?

  • LIST NAMES, MEMBER NUMBERS, CERTIFICATION AGENCY, AND NUMBER

  • ARE NDE PERSONNEL QUALIFIED TO ASNT RECOMMENDED PRACTICE SNT-TC-1A?

II. WELDER FILES

  • IS A SEPARATE FILE MAINTAINED FOR EACH WELDER?

  • DOES THE FILE CONTAIN

III. MATERIAL FILES

  • IS A FILE MAINTAINED FOR TEST COUPON MATERIALS?

  • DOES THE FILE CONTAIN THE FOLLOWING

  • IS A FILE MAINTAINED ON ELECTRODES USED FOR TESTING?

  • DOES THE FILE CONTAIN THE FOLLOWING?

  • LOG FOR TEST ELECTRODES RECEIVED

IV. CONTRACT SERVICES

  • ARE NDE SERVICES CONTRACTED OUT?

  • IS THERE A STATEMENT OF CONTRACTOR QUALIFICATION ON FILE?

  • IS THE WELDER IDENTIFICATION CODE (TEST # AND/OR LETTERS) PLACED ON NDE SPECIMENS?

  • ARE CONTRACTED NDE WELD TEST REPORTS MAINTAINED IN THE WELDERS FILE?

  • ARE CONTRACT NDE PERSONNEL QUALIFIED FOR ASNT SNT‐TC‐1A?

  • ARE NDE WELD SPECIMENS RETRIEVED AND STORED IN A SECURE AREA FOR A MINIMUM OF SIX MONTHS?

V. OPERATIONS

  • IS THE WELDER ASSIGNED A UNIQUE TEST IDENTIFICATION CODE(TEST# AND /OR LETTER) FOR EACH TEST?

  • IS A LOG KEPT FOR ALL TEST ID CODES ISSUED?

  • IS THE TEST IDENTIFICATION CODE (TEST # AND/OR LETTERS) AND POSITION RECORDED ON THE SPECIMEN?

  • ARE THE TEST MATERIAL AND ELECTRODE IDENTIFICATION ID CODES RECORDED ON THE TEST FACILITY WORKSHEET?

  • ARE WRITTEN INSTRUCTIONS AND SKETCHES AVAILABLE FOR THE WELDER TO USE IN THE FITTING UP OF THE TEST ASSEMBLY?

  • IS A WELDING PROCEDURE MADE AVAILABLE TO THE WELDER PRIOR TO FIT UP AND WELDING?

  • IS THE FIT-UP INSPECTED?

  • IS THE COUPON MARKED WITH THE WELDER ID CODE (TEST # AND/OR LETTERS) AND POSITIONED IN THE EXACT LOCATION OF THE TEST SPECIMENS BEFORE WELDING?

  • IS THE POSITIONING OF THE COUPON VERIFIED BEFORE WELDING?

  • IS THE WELDER NOTIFIED THAT REPOSITIONING OF THE WELD COUPON WITHOUT THE APPROVAL OF THE TEST SUPERVISOR WILL INVALIDATE THE TEST?

  • IF NECESSARY, IS REPOSITIONING VERIFIED?

  • IS THE ROOT PASS VISUALLY INSPECTED BY THE TEST SUPERVISOR PRIOR TO THE NEXT WELDING OPERATION?

  • IS THE FINISHED WELD VISUALLY INSPECTED BY THE TEST SUPERVISOR PRIOR TO REMOVAL OF THE TEST POSITION?

  • ARE WRITTEN PROCEDURES FOR THE VISUAL INSPECTION OF FINISHED WELD AVAILABLE?

  • ARE WRITTEN PROCEDURES FOR DESTRUCTIVE TESTING OF WELD SPECIMENS AVAILABLE?

  • IS THE TEST IDENTIFICATION CODE (TEST # AND/OR LETTERS) ON TEST SPECIMENS VERIFIED PRIOR TO TESTING?

  • ARE TEST RESULTS MARKED ON THE WELDER TEST FACILITY WORKSHEET AND WPQR?

  • ARE BEND OR OTHER SPECIMENS STORED IN A SECURE AREA FOR A MINIMUM OF SIX MONTHS?

  • ARE WRITTEN PROCEDURES AVAILABLE FOR DESTROYING AND DISPOSAL OF SPECIMENS?

VI. OFF-SITE TESTING

  • WILL WELDERS BE TESTED OFF SITE?

  • WILL ACCREDITED TEST FACILITY TEST MATERIALS AND FILLER METALS BE USED?

  • ARE ALL REQUIREMENTS OF SECTIONS II, III, AND V OF THIS CHECKLIST MET FOR MATERIALS AND FILLER METALS USED?

  • ARE AMPERAGE AND VOLTAGE VERIFIED USING THE FACILITIES CALIBRATED AMP/VOLT METER?

VII.REFERANCE DOCUMENTS

  • ARE CURRENT COPIES OF APPLICABLE WELDER QUALIFICATION CODES AVAILABLE TO WELDERS?

  • AWS D1.1 – STRUCTURAL WELDING CODE‐STEEL(2020)

  • YEAR

  • AWS D1.2 – STRUCTURAL WELDING CODE‐ALUMINUM (2014)

  • YEAR

  • AWS D1.3 – STRUCTURAL WELDING CODE SHEET STEEL(2018)

  • YEAR

  • AWS D1.4 – STRUCTURAL WELDING CODE REINFORCING STEEL (2018)

  • YEAR

  • AWS D1.5 – BRIDGE WELDING CODE(2020)

  • YEAR

  • AWS D1.6 – STRUCTURAL WELDING CODE STAINLESS STEEL (2017)

  • YEAR

  • AWS D1.8 – STRUCTURAL WELDING CODE‐SEISMIC SUPPLEMENT (2021)

  • YEAR

  • viii. AWS B2.1 – WELDING PROCEDURE AND PERFORMANCE QUALIFICATION STANDARD(2021)

  • YEAR

  • ASME SEC. IX – QUALIFICATION STANDARD FOR WELDING AND BRAZING PROCEDURES, WELDING AND BRAZING OPERATORS

  • YEAR

  • API 1104 – STANDARD FOR WELDING PIPELINES AND RELATED FACILITIES

  • YEAR

MECHANICAL TESTING

  • i. AWS B4.0 – STANDARD METHODS FOR MECHANICAL TESTING OF WELDS (2016)

  • YEAR

NON DESTRUCTIVE TESTING AND INSPECTION

  • ASNT TC 1A‐ RECOMMENDED PRACTICE No. SNT‐TC‐1A

  • YEAR

  • ASTM E165‐ LIQUID PENETRANT INSPECTION METHOD

  • YEAR

  • ASTM E709‐ MAGNETIC PARTICLE EXAMINATION

  • YEAR

  • ASTM E94‐ RADIOGRAPHIC TESTING

  • YEAR

  • ASTM E1032‐ RADIOGRAPHIC EXAMINATION OF WELDMENTS

  • YEAR

  • ASTM E164‐ ULTRASONIC CONTACT EXAMINATION OF WELDMENTS

  • YEAR

QUALIFICATION AND CERTIFICATION

  • AWS QC 1 – STANDARD FOR AWS CERTIFICATION OF WELDING INSPECTORS (2016)

  • YEAR

  • AWS B5.2 – SPECIFICATION FOR THE QUALIFICATION OF WELDING INSPECTOR SPECIALIST AND WELDING INSPECTOR ASSISTANCES(2018)

  • YEAR

  • AWS QC 4 – STANDARD FOR ACCREDITATION OF TEST FACILITIES FOR AWS CERTIFIED WELDER PROGRAMS (1989)

  • YEAR

  • AWS QC 5 – AWS STANDARD FOR CERTIFICATION OF WELDING EDUCATORS (1991)

  • YEAR

  • AWS QC 7 – STANDARD FOR AWS CERTIFIED WELDERS(1993)

  • YEAR

  • AWS QC 7 – Supplement G – AWS PERFORMANCE QUALIFICATION TEST(1993)

  • YEAR

SAFETY AND HEALTH

  • ANSI Z49.1‐ SAFETY IN WELDING, CUTTING, AND ALLIED PROCESSES(2021)

  • YEAR

VIII. WELDING AND CUTTING EQUIPMENT

  • ATTACH PHOTOS OF THE WELD SHOP AND BOOTH INTERIORS HERE.

  • TOTAL NUMBER OF BOOTHS

  • NUMBER OF SMAW UNITS

  • NUMBER OF FCAW UNITS

  • NUMBER OF GMAW UNITS

  • NUMBER OF GTAW UNITS

  • NUMBER OF SAW UNITS

  • OTHER PROCESSES USED:

  • NUMBER OF OXY‐FUEL CUTTING/GOUGING STATIONS

  • TYPE OF FUEL GAS USED:

  • NUMBER OF CAC‐A UNITS

  • NUMBER OF PAC UNITS

  • TYPE OF MECHANICAL SAW

  • HOW ARE TEST SPECIMENS REMOVED FROM TEST COUPONS?

IX. TESTING EQUIPMENT

  • TYPE OF BEND TESTER UTILIZED?

  • DOES THE BEND TESTER CONFORM TO THE SPECIFICATIONS IN THE APPROPRIATE CODE?

  • IS THERE OTHER TESTING EQUIPMENT BEING USED?

  • Fillet Nick Break Fixture

  • Tensile Test Machine

  • Impact Testing Machine

MEASURING TOOLS AVAILABLE:

  • ATTACH PHOTOS OF TOOLS HERE.

  • MEASURING TAPE?

  • STEEL RULER?

  • MICROMETER?

  • DIAL CALIPER?

  • OPTICAL AID?

  • FILLET WELD GAUGE KIT?

  • WELD REINFORCEMENT GAUGE?

  • HI‐LOW GAUGE?

  • UNDERCUT GAUGE?

  • ARE MACRO ETCH TESTS PERFORMED ON SITE?

  • ARE WRITTEN PROCEDURES AVAILABLE?

X. WELDING AND CALIBRATION EQUIPMENT MAINTENANCE LOG AND RECORDS (i.e. WELDING MACHINES, METER, OVEN, BENDER)

  • IS A WRITTEN MAINTENANCE PROCEDURE ESTABLISHED?

  • IS THE MAINTENANCE LOG FOR EACH PIECE OF EQUIPMENT UP TO DATE?

  • IS EQUIPMENT IDENTIFIED?

  • ARE CALIBRATION METHODS DEFINED?

  • DOES EQUIPMENT HAVE A CURRENT CALIBRATION TAG?

  • ARE OPERATING MANUALS AVAILABLE?

XI. GENERAL

  • DOES EQUIPMENT APPEAR WELL MAINTAINED?

  • IS LIGHTING IN THE WELDING AREA ADEQUATE?

  • DOES THE WELDING AREA APPEAR CLEAN?

  • ARE FIRE EXTINGUISHERS READILY AVAILABLE AND UP TO DATE?

  • IS A FIRST AID KIT READILY AVAILABLE?

ARE THERE ADEQUATE NUMBER OF:

  • WELDING HOODS?

  • WELDING SLEEVES OR JACKETS?

  • WELDING GLOVES?

  • CUTTING GOGGLES?

  • CHIPPING HAMMERS AND WIRE BRUSHES?

  • IS THE ROD OVEN TEMPERATURE MAINTAINED AS REQUIRED BY THE CODE?

  • ARE WRITTEN PROCEDURES ON FILE FOR RECORD RETENTION?

  • ARE ALL RECORDS RETAINED FOR A MINIMUM OF FIVE YEARS?

  • ARE RECORDS MAINTAINED IN A SECURE AREA?

  • IS THE FACILITY ACCREDITED BY ANY OTHER ORGANIZATION?

  • WHAT ORGANIZATION?

  • IS THERE A WRITTEN TRAINING PLAN IN PLACE TO MAINTAIN AND IMPROVE STAFF SKILLS AND PROGRAM PERFORMANCE?

  • IS THE QA PROGRAM AUDITED ANNUALLY?

  • ARE COPIES OF THE AUDIT DOCUMENTS KEPT ON FILE?

  • WHO IS RESPONSIBLE FOR THE SELF-AUDIT?

  • WHEN WAS THE LAST AUDIT PERFORMED?

  • AUDITORS

  • FACILITIES REPRESENTATIVE

Final Conclusion

  • Notes:

  • Recommendation of Auditor

Program Manager

  • Approved or Disapproved

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.