Title Page
-
Site conducted
-
Conducted on
-
Prepared by
-
Superintendent in Charge
-
Weather Conditions & Temperature (AM & PM)
Safety Equipment & Conditions
-
DOL/OSHA Required Poster Posted
-
Emergency Action Plan Posted
-
Safety Department & Project Management Phone Numbers Posted
-
Employee CPR/FA trained on site
-
Fully stocked First Aid Kit Available
-
First Aid Kit in date
-
PPE for rendering First Aid available? Exam gloves, face shield, cpr mask
-
Eye wash stations available within 10 seconds walk of employees performing work that produces flying debris (pouring concrete, cutting wood/rebar)
-
Emergency Eye Wash station inspected?
-
Eye wash station fluid in date?
-
Fluid Changed? replaced with potable water and eye wash solution concentrate
-
Access to drinking water (cold water in hot weather)
-
Restrooms available and clean
-
PTP filled out correctly and being used
-
CAZ properly barricaded and signage on all sides (signs should include: name of responsible party, phone number and company name, hazard inside of CAZ)
-
Required permits filled out and available (Excavation, hot work, confined space, ladder, concrete pump)
-
Competent person on site and inspecting frequently
-
Superintendent notified? Who
-
Are there enough personnel to complete the tasks safely for the day?
HOUSEKEEPING
-
Is there General neatness of the work area?
-
Are projecting nails removed?
-
Are waste containers provided and used?
-
Are passageways and walkways clear
-
Is lighting adequate?
-
Is the lay down yard near and organized? (Rebar caps on verticals)
FIRE PREVENTION
-
Are there adequate fire extinguishers that are accessible and inspected (monthly/annually)
-
Are flammable liquids stored properly
-
Flammable Cabinet clear of items stored on top?
-
Bulk flammable storage and/or bulk fueling tank area have at least a 20lb ABC extinguisher no closer than 25ft and not farther than 75ft of the storage area?
-
Are no smoking signs posted and enforced.
-
Combustibles stored away from flammables?
-
Are funnels being used when refilling equipment
-
Is equipment shut down while fueling?
-
Is propane stored at least 25’ from occupied structures?
ELECTRICAL
-
All power cords inspected for frays, bare wires, missing ground pins or other damage?
-
Any cords taken out of service?
-
Are GFCI being used?
-
Are terminal boxes equipped with required covers?
-
Are flexible cords protected from damage (not being run over by equipment, shut in doors etc)
-
Are cords suspended above wet areas or areas with standing water?
-
Are generators inspected and grounded
-
Are multiple cords connected together (Daisey Chained)?
-
cords removed from service?
-
Are multi outlet splitters/Power strips in use?
-
Removed From Service?
HAND TOOLS / POWER TOOLS
-
Are hand tools inspected frequently?
-
Are broken handles, mushroom heads present?
-
Are protective guards in place on tools
-
Is the right tool being used for the job
-
Powder actuated tools in use? If so, are operators licensed?
-
Operator Licensed? (Include CERT)
-
Are operators using proper PPE
-
Are tools neatly stored and carried properly?
FALL PROTECTION
-
Are employees working more than 6’ above a lower level protected by guardrails, safety nets, PFAS
-
Are guardrails/safety nets secured properly and located at correct heights?
-
Are employees exposed to fall hazards using PFAS and properly tied off? (5k anchor point, correct lanyard)
-
Are employees using turbos along with rebar chains when positioning?
-
Handrails at inclines (such as excavations)
-
Steps of not more than 9.5”
-
Steps have a proper landing?
-
Steps have a hand rail?
-
Tools/hard hats equipped with lanyard?
-
Barricade around excavation?
LADDERS
-
Ladder permit in use?
-
Job Built ladders meet OSHA spec?
-
Are ladders at least 3’ above landing
-
Are ladders secured at top and bottom?
-
Corral and offset in place to prevent falls?
-
Damaged ladder taken out of service?
-
Why was the ladder taken out of service. (include Photos)
-
All ladders equipped with all decals?
-
Step ladders used in the fully open and locked position
SCAFFOLDING
-
Has scaffolding been inspected by a competent person?
-
Is there a green tag present and signed on correct date?
-
Is scaffolding erected on sound level footing?
-
Plumb, square with cross bracing?
-
Are guardrails, midrails, toeboards or screens in place?
-
Is planking full, sound and sturdy?
-
Overlap of at least 12” at corners, intersections and edges of planking?
-
Working areas free of dirt, snow, ice and grease?
-
Are employees below protected from falling objects?
-
Is fall protection available and in use?
FLOOR AND WALL OPENINGS
-
Are all floor or deck openings planked over or barricaded?
-
Is perimeter protection in place?
-
Are deck planks secured?
-
Are materials stored away from the edge?
-
Is corral in place with offset entrance and toe boards to prevent falls to lower level?
-
Do all corrals, covers and barricades include signage?
TRENCHES, EXCAVATIONS & SHORING
-
Competent person present and inspecting?
-
Are excavations 4’ or greater sloped or benched?
-
Are materials and spoil pile at least 2ft from edge of excavation?
-
Is equipment at least 2ft away from edge of excavation?
-
Are ladders provided every 25’ and secured top and bottom?
-
Have underground utilities been located?
-
Excavation permit completed?
-
Does mobile equipment have spotters?
-
Are swing radius markers in place on equipment?
-
Are Flagger wearing class 3 vests and have traffic wands?
-
What is the soil class? Pentrometer used? What is the pentrometer reading?
-
Excavation sloped properly for class of soil?
-
Are handrails used to enter/exit excavations?
MATERIAL HANDLING
-
Are materials properly stored or stacked
-
Dunnage being used?
-
Tag lines used to guide loads?
-
Are there adequate employees for the operation?
-
Rebar 90D bars covered while in staging area?
-
Material free rigged from from forklift mast?
-
Material secured to forks/mast with strap?
-
Materials properly rigged to forklift?
WELDING & CUTTING
-
Are compressed gas cylinders stored upright and secured?
-
Is there 20ft min separation between fuels and oxygen?
-
Fire extinguishers within 25ft?
-
Hoses and regulators in good condition?
CRANES
-
Crane operator certified for type of crane being used?
-
Daily crane inspection completed?
-
Lift chart present in crane?
-
Chains, rigging hardware and slings inspected and tagged as required?
-
Hand signal charts located in crane?
-
Crane Operator DOT physical in date?
-
Warning whistles being used?
-
Clear communication between signalman and crane operator?
CONCRETE CONSTRUCTION / SILICA
-
Proper PPE being worn (faceshield,apron,chem gloves for pouring concrete) N95/Respirator for cutting/drilling ops
-
Are employees protected from cement dust?
-
Is exposed skin covered?
-
Are walls over 8’ supported properly?
-
Rebar covered by caps?
-
Concrete pump permit complete?
-
Saw cut operations producing acceptable amount of dust?
-
Cutting operations using water/vacuum as deigned?
-
Concrete bucket in good condition?
PERSONAL PROTECTIVE EQUIPMENT
-
Hard hats, Safety glasses, vests and gloves being worn properly?
-
Faceshields being worn when needed? (Any operation producing flying debris)
-
Are respirators being used when required/needed?
-
Hearing protection being worn in environments greater than 90db?
MOBILE EQUIPMENT
-
Mobile Equipment equipped with back-up alarm?
-
Maintenance Department Notified?
-
Inspection report complete? (include 1 per week at random)
-
Operators certified for equipment?
-
Seat belts being used
-
Fire extinguisher on machine and inspected?
-
All machines have a century label on them?
-
Mobile Equipment not used within 2 feet of excavation?
STAIRS
-
Stairs with more than 4 risers equipped with handrail?
-
Metal pan stairs filled with wood until filled with concrete?
-
Proper landing at top of stairs?
-
Stair risers no more than 9.5”
HAZARD COMMUNICATION
-
Is there an SDS available to all employees?
-
SDS inventory on site and accurate?
-
Each original container labeled with product identifier, signal words, hazard statement, pictograms, precautionary statements, name, address, phone number of chemical manufacturer.
-
Is each secondary container (example spray cans) labeled with original labeling or product ID and words, pictures, and/or symbols which provide general information regarding the chemical contained inside.
-
Are materials properly stored?
-
Are employees trained in HAZCOM?
Unsafe Actions Observed
-
Please list all unsafe actions observed and the abatement for each
-
Summary of todays activities and conversations had.
-
Conference with GC
-
Name & Title of GC Representative
NEAR MISSES
-
Near Miss today
-
Describe near miss
-
What can we do to prevent the near Miss or incident in the future?
INCIDENTS TODAY?
-
Any first aids today?
-
Short Description of First Aid
-
Root Cause
-
Employee Name / Job Title
-
Name of Superintendent notified
-
Any incidents / Injuries Today?
-
Incident Report Complete?
- Yes
- No
- N/A
-
Injury Report Complete
-
Employee Name / job title
-
Name of superintendent notified of incident/injury
-
Name of GC rep notified
-
Injury type
-
Incident type
-
Employee taken for offsite treatment?
UPCOMING HIGH RISK ACTIVITES
-
Are there any high risk activities coming up in the next 4-6 weeks?
-
List high risk activities
-
Special PPE needed? (PFAS, SRL, MEWP)
TRAINING / TOOL BOX TALK
-
Topic of training
-
Copy of roster sent to GC?
SAFETY PRO COMPLETING REPORT
-
Add signature